Geothermal Waste Heat Utilization from In Situ Thermal Bitumen Recovery Operations

被引:3
作者
Nakevska, Nevenka [1 ]
Schincariol, Robert A. [1 ]
Dehkordi, S. Emad [1 ]
Cheadle, Burns A. [1 ]
机构
[1] Univ Western Ontario, Dept Earth Sci, London, ON N6A 5B7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
ASSISTED GRAVITY DRAINAGE; SAGD PROCESS; PERFORMANCE; SIMULATION; ENERGY;
D O I
10.1111/gwat.12196
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
In situ thermal methods for bitumen extraction introduce a tremendous amount of energy into the reservoirs raising ambient temperatures of 13 degrees C to as high as 200 degrees C at the steam chamber edge and 50 degrees C along the reservoir edge. In essence these operations have unintentionally acted as underground thermal energy storage systems which can be recovered after completion of bitumen extraction activities. Groundwater flow and heat transport models of the Cold Lake, Alberta, reservoir, coupled with a borehole heat exchanger (BHE) model, allowed for investigating the use of closed-loop geothermal systems for energy recovery. Three types of BHEs (single U-tube, double U-tube, coaxial) were tested and analyzed by comparing outlet temperatures and corresponding heat extraction rates. Initial one year continuous operation simulations show that the double U-tube configuration had the best performance producing an average temperature difference of 5.7 degrees C, and an average heat extraction of 41 W/m. Given the top of the reservoir is at a depth of 400 m, polyethylene piping provided for larger extraction gains over more thermally conductive steel piping. Thirty year operation simulations illustrate that allowing 6 month cyclic recovery periods only increases the loop temperature gain by a factor of 1.2 over continuous operation. Due to the wide spacing of existing boreholes and reservoir depth, only a small fraction of the energy is efficiently recovered. Drilling additional boreholes between existing wells would increase energy extraction. In areas with shallower bitumen deposits such as the Athabasca region, i.e. 65 to 115 m deep, BHE efficiencies should be larger.
引用
收藏
页码:251 / 260
页数:10
相关论文
共 39 条
  • [1] Adegbesan K. O., 2007, GAS OVER BITUMEN RES
  • [2] [Anonymous], 2010, 2010 SURVEY ENERGY R, P93
  • [3] [Anonymous], 2012, INTRO THERMOGEOLOGY
  • [4] [Anonymous], 2013, Technical report
  • [5] Attanasi E.D. A. M., 2010, Survey of Energy Resources, P123
  • [6] Bachu S., 1996, 199601 OFR ALB GEO 6
  • [7] Bachu S, 2004, B CANADIAN PETROLEUM, V47, P455
  • [8] CAPP, 2013, FACTS OIL SANDS, V58
  • [9] Chiasson A.D., 1999, Advances in modeling of ground-source heat pump systems
  • [10] Chiasson A.D., 2000, ASHRAE T, V106, P380