A novel three-dimensional printed device with conductive elements for electromembrane extraction combined with high-performance liquid chromatography and ultraviolet detector

被引:6
作者
Dolatabadi, Roshanak [1 ]
Mohammadi, Ali [1 ]
Walker, Roderick B. [2 ,3 ]
机构
[1] Univ Tehran Med Sci, Dept Drug & Food Control, Fac Pharm, Tehran, Iran
[2] Food & Drug Adm, Iran Minist Hlth & Med Educ, Tehran, Iran
[3] Rhodes Univ, Div Pharmaceut, Fac Pharm, Eastern Cape, South Africa
关键词
conductive vial; electromembrane extraction; phenobarbital; phenytoin; three-dimensional printing; BASIC DRUGS; PLASMA SAMPLES; MICROEXTRACTION; MEMBRANE;
D O I
10.1002/jssc.202200028
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper is focused on proposing a new design and setup for electromembrane extraction. A new cap was designed and conductive vials of different shapes were fabricated using three-dimensional printing. The new cap holds three fibers to enhance electromembrane extraction recovery. Conductive vials can simultaneously perform as electrodes therefore, there is no need to include an electrode in sample solutions. Phenobarbital and phenytoin were used as model compounds to assess the setup performance. Under optimal conditions, these analytes were extracted from the sample solution at pH = 9 to the acceptor solution at pH = 13 with a voltage of 40 V for 20 min, while 1-octanol was employed as the supported-liquid-membrane. The influence of conductive vials geometry on the recovery was examined and the effects of different shapes were studied by performing numerical simulation to establish electric potential distribution. Of the vials tested with circular, triangular, and floral-like cross-sections the latter exhibited the best voltage distribution. The circular vial had the highest recovery attributed to its better hydrodynamic shape, which allows rapid fluid sample transport and therefore enhanced system recovery. The extraction recovery and relative standard deviation of the circular vial with three fibers were 33.0 and 7.6 for phenobarbital and 42.2 and 10.4 for phenytoin.
引用
收藏
页码:3187 / 3196
页数:11
相关论文
共 48 条
[1]   Chromium speciation using paper-based analytical devices by direct determination and with electromembrane microextraction [J].
Alahmad, Waleed ;
Varanusupakul, Puttaruksa ;
Kaneta, Takashi ;
Varanusupakul, Pakorn .
ANALYTICA CHIMICA ACTA, 2019, 1085 :98-106
[2]   Current trends in green sample preparation before liquid chromatographic bioanalysis [J].
Alampanos, Vasileios ;
Samanidou, Victoria .
CURRENT OPINION IN GREEN AND SUSTAINABLE CHEMISTRY, 2021, 31
[3]   Pulsed electromembrane method for simultaneous extraction of drugs with different properties [J].
Arjomandi-Behzad, Leila ;
Yamini, Yadollah ;
Rezazadeh, Maryam .
ANALYTICAL BIOCHEMISTRY, 2013, 438 (02) :136-143
[4]   Optimization of solid-phase microextraction procedures for the determination of tricyclic antidepressants and anticonvulsants in plasma samples by liquid chromatography [J].
Cantu, Marcelo Delmar ;
Toso, Daniel Rodrigo ;
Lacerda, Cristina Alves ;
Lancas, Fernando Mauro ;
Carrilho, Emanuel ;
Queiroz, Maria Eugenia Costa .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (02) :256-263
[5]   Determination of Antiepileptic Drugs Using Dried Saliva Spots [J].
Carvalho, Joana ;
Rosado, Tiago ;
Barroso, Mario ;
Gallardo, Eugenia .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2019, 43 (01) :61-71
[6]   One step multi-material 3D printing for the fabrication of a photometric detector flow cell [J].
Cecil, Farhan ;
Guijt, Rosanne M. ;
Henderson, Alan D. ;
Macka, Mirek ;
Breadmore, Michael C. .
ANALYTICA CHIMICA ACTA, 2020, 1097 :127-134
[7]   Quantification of carbamazepine, carbamazepine-10,11-epoxide, phenytoin and phenobarbital in plasma samples by stir bar-sorptive extraction and liquid chromatography [J].
Costa Queiroz, Regina Helena ;
Bertucci, Carlo ;
Malfara, Wilson Roberto ;
Carvalho Dreossi, Sonia Aparecida ;
Chaves, Andrea Rodrigues ;
Rodrigues Valerio, Daniel Augusto ;
Costa Queiroz, Maria Eugenia .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 48 (02) :428-434
[8]   A study on determination of theophylline in plasma and urine sample using electromembrane extraction combined with high-performance liquid chromatography-ultraviolet [J].
Dolatabadi, Roshanak ;
Zaheri, Mohammadreza ;
Ebrahimi, Shahriar ;
Mohammadi, Ali .
CHEMICAL PAPERS, 2022, 76 (02) :681-690
[9]   An Electrodiffusion Model Coupled with Fluid-Flow Effects for an On-Chip Electromembrane Extraction System [J].
Dolatabadi, Roshanak ;
Gharehnazifam, Ziba ;
Moraffah, Fatemeh ;
Mohammadi, Ali ;
Baghani, Mostafa .
TRANSPORT IN POROUS MEDIA, 2022, 142 (1-2) :317-331
[10]   Electromembrane extraction-high-performance liquid chromatography-ultraviolet detection of phenobarbital and phenytoin in human plasma, saliva, and urine [J].
Dolatabadi, Roshanak ;
Mohammadi, Ali ;
Nojavan, Saeed ;
Yaripour, Saeid ;
Tafakhori, Abbas ;
Shirangi, Mehrnoosh .
JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2021, 68 (08) :1522-1530