Feasibility and Safety of MR-Guided Focused Ultrasound Lesioning in the Setting of Deep Brain Stimulation

被引:4
作者
Dallapiazza, Robert [1 ]
Khaled, Mohamad [1 ]
Eames, Matthew [4 ]
Snell, John [4 ]
Lopes, M. Beatriz [2 ]
Wintermark, Max [3 ]
Elias, W. Jeffrey [1 ]
机构
[1] Univ Virginia, Dept Neurosurg, Charlottesville, VA USA
[2] Univ Virginia, Dept Neuropathol, Charlottesville, VA USA
[3] Univ Virginia, Dept Radiol, Charlottesville, VA USA
[4] Focused Ultrasound Surg Fdn, Charlottesville, VA USA
关键词
Focused ultrasound; Thalamotomy; Magnetic resonance imaging compatibility; Deep brain stimulation; Movement disorders; Thermography; ESSENTIAL TREMOR; DBS; SYSTEMS; DAMAGE; SKULL;
D O I
10.1159/000368908
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Patients treated with deep brain stimulation (DBS) often develop symptom progression. If safe, focused ultrasound (FUS) lesioning could be used for patients unable to undergo further DBS surgery. Objective: To test the feasibility and safety of MR-guided FUS surgery in the setting of a previously implanted DBS system. Methods:Three preclinical experiments were designed to test feasibility and safety. Hydrogels were implanted with an electrode, and FUS lesions were targeted adjacently. Cadavers were implanted with a thalamic electrode, and FUS lesions were targeted in the contralateral thalamus. Finally, DBS systems were implanted in swine, and FUS lesioning was targeted to the contralateral thalamus, MRI was used to assess the treatments, and histological analyses were performed at 2 days and at 1 month. Results: In gel experiments and cadavers, FUS resulted in target heating to 29-32 degrees C without any heating at the electrode. In animal experiments, there were no FUS-related MRI signal changes near the electrode. Histological analysis showed typical FUS lesions with no evidence of damage surrounding the electrode tracts. Conclusions: FUS is feasible in the setting of a preimplanted DBS device. There was minimal heating of the device during the procedure and no apparent FUS-related tissue injury. (C) 2015 S. Karger AG, Basel
引用
收藏
页码:140 / 146
页数:7
相关论文
共 50 条
[41]   MR-Guided, Focused Ultrasound: Applications to Essential Tremor and Other Neurologic Conditions [J].
Suffredini, G. ;
Levy, L. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (05) :829-831
[42]   The reduction in treatment efficiency at high acoustic powers during MR-guided transcranial focused ultrasound thalamotomy for Essential Tremor [J].
Hughes, Alec ;
Huang, Yuexi ;
Schwartz, Michael L. ;
Hynynen, Kullervo .
MEDICAL PHYSICS, 2018, 45 (07) :2925-2936
[43]   Effectiveness and safety of MR-guided focused ultrasound thalamotomy in patients with essential tremor and low skull density ratio: a study of 101 cases [J].
Hino, Sakae ;
Maki, Futaba ;
Yamaguchi, Toshio ;
Kaburagi, Mayumi ;
Nakano, Masayuki ;
Iwamuro, Hirokazu ;
Takasaki, Masahito ;
Iijima, Ken ;
Kanouchi, Masashi ;
Sasanuma, Jinichi ;
Watanabe, Kazuo ;
Hasegawa, Yasuhiro ;
Yamano, Yoshihisa .
JOURNAL OF NEUROSURGERY, 2024, 141 (01) :212-220
[44]   Thalamic Deep Brain Stimulation Salvages Failed Focused Ultrasound Thalamotomy for Essential Tremor: A Case Report [J].
Wang, Tony R. ;
Dallapiazza, Robert F. ;
Moosa, Shayan ;
Huss, Diane ;
Shah, Binit B. ;
Elias, W. Jeffrey .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2018, 96 (01) :60-64
[45]   T1-weighted MRI as a substitute to CT for refocusing planning in MR-guided focused ultrasound [J].
Wintermark, Max ;
Tustison, Nicholas J. ;
Elias, William J. ;
Patrie, James T. ;
Xin, Wenjun ;
Demartini, Nicholas ;
Eames, Matt ;
Sumer, Suna ;
Lau, Benison ;
Cupino, Alan ;
Snell, John ;
Hananel, Arik ;
Kassell, Neal ;
Aubry, Jean-Francois .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (13) :3599-3614
[46]   MR-Guided Focused Ultrasound for the Treatment of Tremor in Fragile X-Associated Tremor/Ataxia Syndrome [J].
Garcia-de Soto, Jesus ;
Pouso-Diz, Jessica Maria ;
Fernandez-Pajarin, Gustavo ;
Roman-Pena, Paula ;
alvarez-Noval, Amanda ;
Blanco-Ulla, Miguel ;
Aran-Echabe, Eduardo ;
Ares, Begona ;
Sesar, Angel .
MOVEMENT DISORDERS CLINICAL PRACTICE, 2024,
[47]   Transcranial MR-Guided Focused Ultrasound and Hyperostosis Calvariae Diffusa: Case Report and Systematic Review of the Literature [J].
Bernstock, Joshua D. ;
Torio, Erickson F. ;
Raghu, Ashley L. B. ;
Chua, Melissa ;
Chen, Jason Andrew ;
Segar, David ;
Gupta, Saksham ;
White, Philip Jason ;
McDannold, Nathan ;
Golby, Alexandra J. ;
Cosgrove, G. Rees .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2023, 100 (5-6) :331-339
[48]   Novel acoustic coupling bath using magnetite nanoparticles for MR-guided transcranial focused ultrasound surgery [J].
Allen, Steven P. ;
Steeves, Tom ;
Fergusson, Austin ;
Moore, Dave ;
Davis, Richey M. ;
Vlaisialjevich, Eli ;
Meyer, Craig H. .
MEDICAL PHYSICS, 2019, 46 (12) :5444-5453
[49]   Volumetric hyperthermia delivery using the ExAblate Body MR-guided focused ultrasound system [J].
Kim, Kisoo ;
Gupta, Pragya ;
Narsinh, Kazim ;
Diederich, Chris J. ;
Ozhinsky, Eugene .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2024, 41 (01)
[50]   Lesion 3D modeling in transcranial MR-guided focused ultrasound thalamotomy [J].
Lopez-Aguirre, Miguel ;
Caballero-Insaurriaga, Jaime ;
Urso, Daniele ;
Rodriguez-Rojas, Rafael ;
Manez-Miro, Jorge U. ;
Del-Alamo, Marta ;
Rachmilevitch, Itay ;
Martinez-Fernandez, Raul ;
Pineda-Pardo, Jose A. .
MAGNETIC RESONANCE IMAGING, 2021, 80 :71-80