摘要
Objectives: We compared the long-term outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) for treatment of bare-metal in-stent restenosis (ISR). Background: There are no randomized trials or observational studies directly comparing the safety and efficacy of DES versus BMS for treatment of bare-metal ISR. Methods: We examined data on all patients who underwent percutaneous coronary intervention (PCI) for ISR at Cleveland Clinic between 05/1999 and 06/2007. We compared the efficacy and safety of DES to BMS for treating bare-metal ISR. The primary end point was a composite of death, myocardial infarction (MI), or target lesion revascularization (TLR). The secondary endpoints were individual components of the primary endpoint. Results: Of the 931 patients identified over 8 years, 706 had bare-metal ISR and met our study criteria. Of the 706 patients with bare-metal ISR, 362 were treated with DES and 344 with BMS. There were 230 cumulative events for a median follow-up of 3.2 years. After adjusting for 27 variables, DES were associated with lower primary endpoint compared to BMS for treatment of bare-metal ISR (21% vs. 45%, adjusted hazard ratio [HR] 0.63; 95% confidence interval [CI], 0.42-0.95; P = 0.03). The individual secondary endpoint of death (8% vs. 24%, P = 0.005) favored DES, but MI (3% vs. 8%, P = 0.31), and TLR (13% vs. 20%, P = 0.23) failed to reach statistical significance. Conclusions: In our multivariate analysis of patients with bare-metal ISR, DES use was associated with significantly lower death, MI, or TLR when compared to BMS. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:257 / 262
页数:6
相关论文
共 50 条
  • [31] Effectiveness of Drug-Eluting Stents versus Bare-Metal Stents in Large Coronary Arteries in Patients with Acute Myocardial Infarction
    Sim, Doo Sun
    Jeong, Myung Ho
    Ahn, Youngkeun
    Kim, Young Jo
    Chae, Shung Chull
    Hong, Taek Jong
    Seong, In Whan
    Chae, Jei Keon
    Kim, Chong Jin
    Cho, Myeong Chan
    Seung, Ki Bae
    Park, Seung Jung
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2011, 26 (04) : 521 - 527
  • [32] Time Dependency of Outcomes for Drug-Eluting vs Bare-Metal Stents
    Leung, Alexander A.
    Southern, Danielle A.
    Galbraith, P. Diane
    Knudtson, Merril L.
    Philpott, Andrew C.
    Ghali, William A.
    CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (12) : 1616 - 1622
  • [33] Sirolimus-eluting stents for treatment of drug-eluting versus bare-metal stents restenosis: 42-month clinical outcomes from a Chinese single center
    Yan Rong-qiang
    Chen Ji-lin
    Gao Li-jian
    Yang Yue-jin
    Li Jian-jun
    Qiao Shu-bin
    Xu Bo
    Yao Min
    Qin Xue-wen
    Liu Hai-bo
    Wu Yong-jian
    Yuan Jin-qing
    Chen Jue
    You Shi-jie
    Dai Jun
    Gao Run-lin
    CHINESE MEDICAL JOURNAL, 2012, 125 (19) : 3398 - 3403
  • [35] Efficacy and safety of drug-eluting stent implantation for the treatment of in-stent restenosis occurring within bare-metal stent and drug-eluting stent
    Heng Ge
    Qing Zhang
    Wei Zhou
    Qing He
    Zhi-hua Han
    Ben He
    Journal of Zhejiang University SCIENCE B, 2010, 11 : 553 - 560
  • [36] Evaluation of in-stent neointimal tissue components using integrated backscatter intravascular ultrasound: comparison of drug-eluting stents and bare-metal stents
    Muraoka, Yoshitaka
    Sonoda, Shinjo
    Kashiyama, Kuninobu
    Kamezaki, Fumihiko
    Tsuda, Yuki
    Araki, Masaru
    Okazaki, Masahiro
    Otsuji, Yutaka
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (07) : 1635 - 1641
  • [37] Drug eluting stents for the treatment of bare metal in-stent restenosis: long-term outcomes in real world practice
    Appleby, Clare E.
    Khattar, Raj S.
    Morgan, Kenneth
    Clarke, Bernard
    Curzen, Nicholas
    Neyses, Ludwig
    Fath-Ordoubadi, Farzin
    EUROINTERVENTION, 2011, 6 (06) : 748 - 753
  • [38] DRUG-ELUTING STENT VERSUS BARE-METAL STENT IN SAPHENOUS GRAFTS ANGIOPLASTY
    Krastev, Plamen
    Trendafilova, Diana
    Abedinov, Filip
    Petrov, Iliyan
    Simeonov, Peyo
    Angelov, Hristo
    COMPTES RENDUS DE L ACADEMIE BULGARE DES SCIENCES, 2019, 72 (06): : 828 - 832
  • [39] Comparison of the very long term (>1 year) outcomes of drug-eluting stents for the treatment of bare-metal and drug-eluting stent restenosis
    Costa, Jose Ribamar, Jr.
    Sousa, Amanda G. M. R.
    Moreira, Adriana
    da Costa, Ricardo Alves
    Cano, Manuel N.
    Maldonado, Gala
    Neto, Cantidio Campos
    Jardim, Cesar
    Pavanello, Ricardo
    Sousa, Jose Eduardo
    EUROINTERVENTION, 2009, 5 (04) : 448 - 453
  • [40] Long-term follow-up of patients with sirolimus-eluting stents for treatment of bare-metal in-stent restenosis
    Le Feuvre, Claude
    Healy-Brucker, Aude
    Helft, Gerard
    Monsegu, Jacques
    Varenne, Olivier
    Spaulding, Christian
    Collet, Jean P.
    Beygui, Farzin
    Barthelemy, Olivier
    Choussat, Remi
    Montalescot, Gilles
    Metzger, Jean Philippe
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 140 (02) : 219 - 225