Drug-Eluting Stents Versus Bare-Metal Stents for Treatment of Bare-Metal In-Stent Restenosis

被引:18
|
作者
Singh, Inder M. [1 ]
Filby, Steven J. [1 ]
El Sakr, Fredy [1 ]
Gorodeski, Eiran Z. [1 ]
Lincoff, A. Michael [1 ]
Ellis, Stephen G. [1 ]
Shishehbor, Mehdi H. [1 ]
机构
[1] Cleveland Clin, Dept Cardiovasc Med, Inst Heart & Vasc, Cleveland, OH 44195 USA
基金
美国国家卫生研究院;
关键词
in-stent restenosis; drug-eluting stents; bare-metal stents; vascular brachytherapy; revascularization; CORONARY-ARTERY-DISEASE; BALLOON ANGIOPLASTY; FOLLOW-UP; VASCULAR BRACHYTHERAPY; CLINICAL-OUTCOMES; RANDOMIZED-TRIAL; TERM; INHIBIT; PLACEMENT; RADIATION;
D O I
10.1002/ccd.22509
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: We compared the long-term outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) for treatment of bare-metal in-stent restenosis (ISR). Background: There are no randomized trials or observational studies directly comparing the safety and efficacy of DES versus BMS for treatment of bare-metal ISR. Methods: We examined data on all patients who underwent percutaneous coronary intervention (PCI) for ISR at Cleveland Clinic between 05/1999 and 06/2007. We compared the efficacy and safety of DES to BMS for treating bare-metal ISR. The primary end point was a composite of death, myocardial infarction (MI), or target lesion revascularization (TLR). The secondary endpoints were individual components of the primary endpoint. Results: Of the 931 patients identified over 8 years, 706 had bare-metal ISR and met our study criteria. Of the 706 patients with bare-metal ISR, 362 were treated with DES and 344 with BMS. There were 230 cumulative events for a median follow-up of 3.2 years. After adjusting for 27 variables, DES were associated with lower primary endpoint compared to BMS for treatment of bare-metal ISR (21% vs. 45%, adjusted hazard ratio [HR] 0.63; 95% confidence interval [CI], 0.42-0.95; P = 0.03). The individual secondary endpoint of death (8% vs. 24%, P = 0.005) favored DES, but MI (3% vs. 8%, P = 0.31), and TLR (13% vs. 20%, P = 0.23) failed to reach statistical significance. Conclusions: In our multivariate analysis of patients with bare-metal ISR, DES use was associated with significantly lower death, MI, or TLR when compared to BMS. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:257 / 262
页数:6
相关论文
共 50 条
  • [31] Critical role of bare-metal stent controls in trials of drug-eluting stents
    Biondi-Zoccai, GGL
    Agostoni, P
    Abbate, A
    Airoldi, F
    Colombo, A
    EUROPEAN HEART JOURNAL, 2005, 26 (16) : 1686 - 1687
  • [32] Drug-Eluting or Bare-Metal Stents for Coronary Artery Disease
    Bonaa, K. H.
    Mannsverk, J.
    Wiseth, R.
    Aaberge, L.
    Myreng, Y.
    Nygard, O.
    Nilsen, D. W.
    Klow, N. -E.
    Uchto, M.
    Trovik, T.
    Bendz, B.
    Stavnes, S.
    Bjornerheim, R.
    Larsen, A. -I.
    Slette, M.
    Steigen, T.
    Jakobsen, O. J.
    Bleie, O.
    Fossum, E.
    Hanssen, T. A.
    Dahl-Eriksen, O.
    Njolstad, I.
    Rasmussen, K.
    Wilsgaard, T.
    Nordrehaug, J. E.
    NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (13): : 1242 - 1252
  • [33] Drug-eluting or bare-metal stents for acute myocardial infarction
    Mauri, Laura
    Silbaugh, Treacy S.
    Garg, Pallav
    Wolf, Robert E.
    Zelevinsky, Katya
    Lovett, Ann
    Varma, Manu R.
    Zhou, Zheng
    Normand, Sharon-Lise T.
    NEW ENGLAND JOURNAL OF MEDICINE, 2008, 359 (13): : 1330 - 1342
  • [34] Drug-Eluting or Bare-Metal Stents in Large Coronary Arteries
    Aminian, Adel
    Lalmand, Jacques
    NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (12): : 1179 - 1180
  • [35] Comparison in survival outcomes between drug-eluting stents and bare-metal stents
    Omerovic, E.
    EUROPEAN HEART JOURNAL, 2012, 33 : 554 - 554
  • [36] Drug-Eluting or Bare-Metal Stents for Coronary Artery Disease
    Urban, Philip
    Oldroyd, Keith
    Krackhardt, Florian
    NEW ENGLAND JOURNAL OF MEDICINE, 2016, 375 (26): : 2603 - +
  • [37] The comparative safety of bare-metal and drug-eluting intracoronary stents
    Lambert, Nathan D.
    Applegate, Robert J.
    EXPERT REVIEW OF MEDICAL DEVICES, 2010, 7 (05) : 611 - 624
  • [38] Drug-eluting stents versus bare-metal stents in the treatment of aorto-ostial coronary diseases
    Park, DW
    Lee, CW
    Lee, BK
    Park, KH
    Park, CB
    Suh, IW
    Kim, MJ
    Kim, YH
    Hong, MK
    Kim, JJ
    Park, SW
    Park, SJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (7A): : 183H - 183H
  • [39] Outcomes in the Era of Bare-Metal Stents vs the Era of Drug-Eluting Stents
    Rassen, Jeremy A.
    Schneeweiss, Sebastian
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (01): : 33 - 34
  • [40] Effect of Length and Diameter of Drug-Eluting Stents Versus Bare-Metal Stents on Late Outcomes
    Applegate, Robert J.
    Sacrinty, Matthew T.
    Kutcher, Michael A.
    Santos, Renato M.
    Gandhi, Sanjay K.
    Little, William C.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (01) : 35 - 42