3-D Synthetic Imaging Using 128-Channel 2-D Sparse CMUT Array

被引:0
|
作者
Choi, Won Young [1 ]
Kwak, Yun Sang [2 ]
Park, Kwan Kyu [2 ]
机构
[1] Hanyang Univ, Dept Convergence Mech Engn, Seoul, South Korea
[2] Hanyang Univ, Dept Mech Engn, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
synthetic aperture imaging; CMUT; 2D sparse array; point spread function image;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Bio-medical ultrasound imaging has recently gained considerable attention. A two-dimensional (2-D) array is essential for three-dimensional (3-D) volumetric imaging. Fully populated 2-D dense array requires thousands of active elements and their interconnections. We present a 2-D CMUT sparse array with 128 elements for 3-D volumetric imaging. This CMUT sparse array with a die size of 6.3 mm x 6.3 mm consists of 128 elements, which has 24 mu m cells arranged in a 3x3 configuration. This work aims to construct a classical synthetic aperture imaging system, which is one of the imaging methods that use several channels. A switch separates the transmission part from the receiving part, and is controlled by the digital signal of the data acquisition. To measure the point spread function of the synthetic imaging system, imaging experiments were performed on thin wire phantom objects. In this paper, we present a 2-D synthetic imaging system with a switching channel to reduce the system complexity and minimize the cost.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Sparse 2-D Arrays for 3-D phased array imaging - Design methods
    Austeng, A
    Holm, S
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) : 1073 - 1086
  • [2] 3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array
    Harput, Sevan
    Tortoli, Piero
    Eckersley, Robert J.
    Dunsby, Chris
    Tang, Meng-Xing
    Christensen-Jeffries, Kirsten
    Ramalli, Alessandro
    Brown, Jemma
    Zhu, Jiaqi
    Zhang, Ge
    Leow, Chee Hau
    Toulemonde, Matthieu
    Boni, Enrico
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (02) : 269 - 277
  • [3] Sparse 2-D arrays for 3-D phased array imaging - Experimental validation
    Austeng, A
    Holm, S
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (08) : 1087 - 1093
  • [4] 3-D elasticity imaging with a 2-D array
    Fisher, T.
    Hall, T.
    Panda, S.
    Jiang, J.
    Resnick, I.
    Barnes, S.
    MEDICAL PHYSICS, 2007, 34 (06) : 2366 - 2366
  • [5] Hybrid Volume Beamforming for 3-D Ultrasound Imaging using 2-D CMUT Arrays
    Kim, Bae-Hyung
    Song, Tai-Kyong
    Yoo, Yangmo
    Chang, Jin Ho
    Lee, Seunghun
    Kim, Youngil
    Cho, Kyungil
    Song, Jongkeun
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 2246 - 2249
  • [6] VOLUMETRIC ELASTICITY IMAGING WITH A 2-D CMUT ARRAY
    Fisher, Ted G.
    Hall, Timothy J.
    Panda, Satchi
    Richards, Michael S.
    Barbone, Paul E.
    Jiang, Jingfeng
    Resnick, Jeff
    Barnes, Steve
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (06): : 978 - 990
  • [7] 3-D Super-Resolution Ultrasound Imaging using a 2-D Sparse Array with High Volumetric Imaging Rate
    Harput, Sevan
    Christensen-Jeffries, Kirsten
    Brown, Jemma
    Zhu, Jiaqi
    Zhang, Ge
    Leow, Chee Hau
    Toulemonde, Matthieu
    Ramalli, Alessandro
    Boni, Enrico
    Tortoli, Piero
    Eckersley, Robert J.
    Dunsby, Chris
    Tang, Meng-Xing
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [8] 2-D army for 3-D ultrasound imaging using synthetic aperture techniques
    Daher, NM
    Yen, JT
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (05) : 912 - 924
  • [9] An Integrated Circuit With Transmit Beamforming Flip-Chip Bonded to a 2-D CMUT Array for 3-D Ultrasound Imaging
    Wygant, Ira O.
    Jamal, Nafis S.
    Lee, Hyunjoo J.
    Nikoozadeh, Amin
    Oralkan, Oemer
    Karaman, Mustafa
    Khuri-Yakub, Butrus T.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (10) : 2145 - 2156
  • [10] Top Orthogonal to Bottom Electrode (TOBE) 2-D CMUT Arrays for 3-D Photoacoustic Imaging
    Chee, Ryan K. W.
    Sampaleanu, Alexander
    Rishi, Deepak
    Zemp, Roger J.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (08) : 1393 - 1395