Accurate phosphorus metabolite images of the human heart by 3D acquisition-weighted CSI

被引:140
作者
Pohmann, R [1 ]
von Kienlin, M [1 ]
机构
[1] Univ Wurzburg, Dept Biophys, D-97070 Wurzburg, Germany
关键词
chemical shift imaging; acquisition weighting; spatial resolution; cardiac P-31 spectroscopy; high-energy phosphates;
D O I
10.1002/mrm.1110
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Fourier imaging modalities suffer from significant signal contamination between adjacent voxels, especially when the spatial resolution is comparable to the size of the anatomical structures. This contamination can be positive or negative, depending on the spatial response function and the geometry of the object. Such a situation arises in human cardiac P-31 chemical shift imaging (CSI), Acquisition-weighted CSI reduces this contamination substantially, which is demonstrated by comparing conventional CSI to Hanning-weighted 3D P-31-CSI experiments in 13 healthy volunteers at 2 T. The nominal spatial resolution and the total number of scans were identical for both experiments. The improved spatial response function of the acquisition-weighted experiment led to a significantly (P < 0.0001) higher myocardial PCr/ATP ratio (2.05 +/- 0.31, mean +/- SD, N = 33, corrected for saturation and blood contribution) compared to the conventional CSI experiment (1.60 +/- 0.46). This is explained by the absence of negative contamination from skeletal muscle, which also resulted in an increase of the observed SNR (from 5.4 +/- 1.4 to 7.2 +/- 1.4 for ATP). With acquisition-weighted CSI, metabolic images with a nominal resolution of 16 mi could be obtained in a measurement time of 30 min. After correction for the inhomogeneous B, field of the surface coil, these images show uniform ATP distribution in the entire myocardium, including the posterior (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:817 / 826
页数:10
相关论文
共 39 条
[1]  
BEER M, 1998, P 15 ESMRMB SEPT 17, P555
[2]   MYOCARDIAL HIGH-ENERGY PHOSPHATE-METABOLISM AND ALLOGRAFT-REJECTION IN PATIENTS WITH HEART-TRANSPLANTS [J].
BOTTOMLEY, PA ;
WEISS, RG ;
HARDY, CJ ;
BAUMGARTNER, WA .
RADIOLOGY, 1991, 181 (01) :67-75
[3]   PHOSPHATE METABOLITE IMAGING AND CONCENTRATION MEASUREMENTS IN HUMAN HEART BY NUCLEAR-MAGNETIC-RESONANCE [J].
BOTTOMLEY, PA ;
HARDY, CJ ;
ROEMER, PB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (03) :425-434
[4]   MR SPECTROSCOPY OF THE HUMAN HEART - THE STATUS AND THE CHALLENGES [J].
BOTTOMLEY, PA .
RADIOLOGY, 1994, 191 (03) :593-612
[5]   Human cardiac high-energy phosphate metabolite concentrations by 1D-resolved NMR spectroscopy [J].
Bottomley, PA ;
Atalar, E ;
Weiss, RG .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) :664-670
[6]   OPTIMUM FLIP-ANGLES FOR EXCITING NMR WITH UNCERTAIN T-1 VALUES [J].
BOTTOMLEY, PA ;
OUWERKERK, R .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (01) :137-141
[7]  
BOTTOMLEY PA, 1998, P 6 ANN M ISMRM SYDN, P1869
[8]   NMR CHEMICAL-SHIFT IMAGING IN 3 DIMENSIONS [J].
BROWN, TR ;
KINCAID, BM ;
UGURBIL, K .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1982, 79 (11) :3523-3526
[9]  
DECORPS M, 1992, NMR BASIC PRINCIPLES, V27, P119
[10]   CARDIAC METABOLISM IN PATIENTS WITH DILATED AND HYPERTROPHIC CARDIOMYOPATHY - ASSESSMENT WITH PROTON-DECOUPLED P-31 MR SPECTROSCOPY [J].
DEROOS, A ;
DOORNBOS, J ;
LUYTEN, PR ;
OOSTERWAAL, LJMP ;
VANDERWALL, EE ;
DENHOLLANDER, JA .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (06) :711-719