A sensitive molecular imprinted surface plasmon resonance nanosensor for selective determination of trace triclosan in wastewater

被引:79
作者
Atar, Necip [1 ]
Eren, Tanju [1 ]
Yola, Mehmet Lutfi [2 ]
Wang, Shaobin [3 ]
机构
[1] Pamukkale Univ, Dept Chem Engn, Denizli, Turkey
[2] Sinop Univ, Dept Met & Mat Engn, Sinop, Turkey
[3] Curtin Univ, Dept Chem Engn, Perth, WA 6845 USA
关键词
Triclosan; Wastewater; Surface plasmon resonance; Molecular imprinting; Nanosensor; CARBON-PASTE ELECTRODE; NICOTINAMIDE ADENINE-DINUCLEOTIDE; TANDEM MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; VOLTAMMETRIC DETERMINATION; ULTRAVIOLET DETECTION; GOLD NANOPARTICLES; BISPHENOL-A; SCHIFF-BASE; SENSOR;
D O I
10.1016/j.snb.2015.04.076
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Triclosan (TCS) has been widely used as an antibacterial and antifungal agent in household cleaning and personal care products. The widespread use of TCS in the cleaning products poses a potential risk to the ecological system and human health due to its release into sediments, wastewater and ground water resources causing chronicle toxicity to aquatic organisms. However, no simple method is available for its detection and quantitative determination in aqueous solution. A novel molecular imprinted surface plasmon resonance (SPR) chemical sensor was developed for sensitive and selective detection of triclosan (TCS) in wastewater, using allylmercaptane modified gold SPR chip and imprinted poly( 2-hydroxyethyl methacrylate-methacryloylamidoglutamic acid) [p(HEMAGA)] nanofilm. The unmodified and imprinted surfaces of the SPR chip were characterized by Fourier transform infrared (FTIR) spectroscopy, atomic force microscopy (AFM) and contact angle measurements. The developed sensor was validated according to the ICH guideline (International Conference on Harmonisation). The linearity range and detection limit of TCS were obtained as 0.05-1.0 ng/mL and 0.017 ng/mL, respectively. The developed molecular imprinted nanosensor was successfully applied to wastewater samples for the determination of TCS and exhibited excellent performance. (C) 2015 Elsevier By. All rights reserved.
引用
收藏
页码:638 / 644
页数:7
相关论文
共 55 条
[21]   A highly selective colorimetric and turn-on fluorescent chemosensor based on 1-(2-pyridylazo)-2-naphthol for the detection of aluminium(III) ions [J].
Gupta, Vinod Kumar ;
Shoora, Sudhir Kumar ;
Kumawat, Lokesh Kumar ;
Jain, Ajay Kumar .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 209 :15-24
[22]   Selective naked-eye detection of Magnesium (II) ions using a coumarin-derived fluorescent probe [J].
Gupta, Vinod Kumar ;
Mergu, Naveen ;
Kumawat, Lokesh Kumar ;
Singh, Ashok Kumar .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 207 :216-223
[23]   A novel molecular imprinted nanosensor based quartz crystal microbalance for determination of kaempferol [J].
Gupta, Vinod Kumar ;
Yola, Mehmet Lutfi ;
Atar, Necip .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 194 :79-85
[24]   Molecular imprinted polypyrrole modified glassy carbon electrode for the determination of tobramycin [J].
Gupta, Vinod Kumar ;
Yola, Mehmet Lutfi ;
Ozaltin, Nuran ;
Atar, Necip ;
Ustundag, Zafer ;
Uzun, Lokman .
ELECTROCHIMICA ACTA, 2013, 112 :37-43
[25]   A cobalt(II)-selective PVC membrane based on a Schiff base complex of N,N′-bis(salicylidene)-3,4-diaminotoluene [J].
Gupta, VK ;
Singh, AK ;
Mehtab, S ;
Gupta, B .
ANALYTICA CHIMICA ACTA, 2006, 566 (01) :5-10
[26]   Substance flow analysis and assessment of environmental exposure potential for triclosan in mainland China [J].
Huang, Chu-Long ;
Ma, Hwong-Wen ;
Yu, Chang-Ping .
SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 499 :265-275
[27]   Voltammetric determination of cefixime in pharmaceuticals and biological fluids [J].
Jain, Rajeev ;
Gupta, Vinod K. ;
Jadon, N. ;
Radhapyari, K. .
ANALYTICAL BIOCHEMISTRY, 2010, 407 (01) :79-88
[28]   Rapid and selective detection of acetone using hierarchical ZnO gas sensor for hazardous odor markers application [J].
Jia, Qianqian ;
Ji, Huiming ;
Zhang, Ying ;
Chen, Yalu ;
Sun, Xiaohong ;
Jin, Zhengguo .
JOURNAL OF HAZARDOUS MATERIALS, 2014, 276 :262-270
[29]   A voltammetric biosensor based on ionic liquid/NiO nanoparticle modified carbon paste electrode for the determination of nicotinamide adenine dinucleotide (NADH) [J].
Karimi-Maleh, Hassan ;
Sanati, Afsaneh L. ;
Gupta, Vinod Kumar ;
Yoosefian, Mehdi ;
Asif, Mohammad ;
Bahari, Ali .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 204 :647-654
[30]   Electrocatalytic and Simultaneous Determination of Ascorbic Acid, Nicotinamide Adenine Dinucleotide and Folic Acid at Ruthenium(II) Complex-ZnO/CNTs Nanocomposite Modified Carbon Paste Electrode [J].
Karimi-Maleh, Hassan ;
Tahernejad-Javazmi, Fahimeh ;
Daryanavard, Marzieh ;
Hadadzadeh, Hassan ;
Ensafi, Ali A. ;
Abbasghorbani, Maryam .
ELECTROANALYSIS, 2014, 26 (05) :962-970