Impact of Obtaining a Digital Breast Tomosynthesis (DBT) Spot Compression View on Assessment of Equivocal DBT Findings

被引:3
作者
Deleau, Florian [1 ]
Linck, Pierre-Antoine [1 ]
Brouste, Veronique [2 ]
Thomassin-Naggara, Isabelle [3 ]
Depetiteville, Marie-Pierre [1 ]
Boisserie-Lacroix, Martine [1 ]
Chamming's, Foucauld [1 ]
机构
[1] Comprehens Canc Ctr, Inst Bergonie, Dept Radiol, 229 Cours Argonne, F-33076 Bordeaux, France
[2] Comprehens Canc Ctr, Inst Bergonie, Clin & Epidemiol Res Unit, Bordeaux, France
[3] Sorbonne Univ, Hop Tenon, AP HP, Dept Radiol, Paris, France
关键词
breast; diagnostic accuracy; digital breast tomosynthesis; radiation dose; spot compression views; MAMMOGRAPHY; MAGNIFICATION;
D O I
10.2214/AJR.21.27190
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BACKGROUND. A recently introduced digital breast tomosynthesis (DBT) device allows acquisition of DBT spot compression views with a small paddle during DBT acquisition. OBJECTIVE. The purpose of this study was to evaluate the impact on diagnostic performance of obtaining a DBT spot compression view for assessment of equivocal DBT findings. METHODS. This retrospective study included 102 women (mean age, 60 years) in whom a DBT spot compression view was obtained to characterize an equivocal finding on DBT at the performing radiologist's discretion. The DBT examinations were performed from December 14, 2018, to December 18, 2019. Two fellowship-trained breast radiologists and one breast imaging fellow, who were aware of the location of the equivocal lesions, independently reviewed the examinations. Readers first assigned a BI-RADS category using standard DBT views and then immediately assigned a category using the DBT spot compression view. BI-RADS categories 2 and 3 were considered negative, and categories 4A and greater were considered positive. Histology and at least 1 year of imaging follow-up served as the reference standard. Intrareader agreement for one reader and interreader agreement among all readers were evaluated with kappa coefficients. Diagnostic performance was compared between DBT with and DBT without spot compression views by use of McNemar tests. RESULTS. Intrareader agreement increased from 0.43 to 0.72, and interreader agreement increased from 0.21 to 0.45 on the basis of kappa coefficients for DBT without and with spot compression views. Eighteen cancers were present. Compared with standard DBT views, DBT spot compression views yielded significantly increased accuracy for all three readers (75% vs 90%, 74% vs 94%, 72% vs 94%); significantly increased specificity for all three readers (69% vs 90%, 75% vs 94%, 68% vs 93%); and significantly increased sensitivity for one reader (67% vs 94%) without significant change in sensitivity for the two other readers (89% vs 100%, 100% vs 89%). Radiation dose was 1.97 mGy for the DBT spot compression view versus 1.78-1.81 mGy for standard DBT craniocaudal and mediolateral oblique views. CONCLUSION. Use of the DBT spot compression view increased intrareader agreement, interreader agreement, and diagnostic accuracy (primarily owing to improved specificity); the supplemental dose for the spot compression view was slightly higher than that for a standard DBT view. CLINICAL IMPACT. DBT spot compression may help characterize equivocal DBT findings, reducing further workup for benign findings.
引用
收藏
页码:37 / 45
页数:9
相关论文
共 27 条
[1]   Outcome of Architectural Distortion Detected Only at Breast Tomosynthesis versus 2D Mammography [J].
Alshafeiy, Taghreed I. ;
Nguyen, Jonathon V. ;
Rochman, Carrie M. ;
Nicholson, Brandi T. ;
Patrie, James T. ;
Harvey, Jennifer A. .
RADIOLOGY, 2018, 288 (01) :38-46
[2]   EQUIVOCAL MAMMOGRAPHIC FINDINGS - EVALUATION WITH SPOT COMPRESSION [J].
BERKOWITZ, JE ;
GATEWOOD, OMB ;
GAYLER, BW .
RADIOLOGY, 1989, 171 (02) :369-371
[3]   Can Digital Breast Tomosynthesis Replace Conventional Diagnostic Mammography Views for Screening Recalls Without Calcifications? A Comparison Study in a Simulated Clinical Setting [J].
Brandt, Kathleen R. ;
Craig, Daniel A. ;
Hoskins, Tanya L. ;
Henrichsen, Tara L. ;
Bendel, Emily C. ;
Brandt, Stephanie R. ;
Mandrekar, Jay .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (02) :291-298
[4]   Detection and characterization of breast lesions in a selective diagnostic population: diagnostic accuracy study for comparison between one-view digital breast tomosynthesis and two-view full-field digital mammography [J].
Chae, Eun Young ;
Kim, Hak Hee ;
Cha, Joo Hee ;
Shin, Hee Jung ;
Choi, Woo Jung .
BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1062)
[5]   Characterization of Breast Masses in Digital Breast Tomosynthesis and Digital Mammograms: An Observer Performance Study [J].
Chan, Heang-Ping ;
Helvie, Mark A. ;
Hadjiiski, Lubomir ;
Jeffries, Deborah O. ;
Klein, Katherine A. ;
Neal, Colleen H. ;
Noroozian, Mitra ;
Paramagul, Chintana ;
Roubidoux, Marilyn A. .
ACADEMIC RADIOLOGY, 2017, 24 (11) :1372-1379
[6]   Integration of 3D digital mammography with tomosynthesis for population breast-cancer screening (STORM): a prospective comparison study [J].
Ciatto, Stefano ;
Houssami, Nehmat ;
Bernardi, Daniela ;
Caumo, Francesca ;
Pellegrini, Marco ;
Brunelli, Silvia ;
Tuttobene, Paola ;
Bricolo, Paola ;
Fanto, Carmine ;
Valentini, Marvi ;
Montemezzi, Stefania ;
Macaskill, Petra .
LANCET ONCOLOGY, 2013, 14 (07) :583-589
[7]   Five Consecutive Years of Screening with Digital Breast Tomosynthesis: Outcomes by Screening Year and Round [J].
Conant, Emily F. ;
Zuckerman, Samantha P. ;
Mcdonald, Elizabeth S. ;
Weinstein, Susan P. ;
Korhonen, Katrina E. ;
Birnbaum, Julia A. ;
Tobey, Jennifer D. ;
Schnall, Mitchell D. ;
Hubbard, Rebecca A. .
RADIOLOGY, 2020, 295 (02) :285-293
[8]   MAMMOGRAPHIC FEATURES OF INVASIVE LOBULAR AND INVASIVE DUCTAL CARCINOMA OF THE BREAST - A COMPARATIVE-ANALYSIS [J].
CORNFORD, EJ ;
WILSON, ARM ;
ATHANASSIOU, E ;
ELLIS, IO ;
ELSTON, CW ;
BLAMEY, RW .
BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (809) :450-453
[9]   Addition of Tomosynthesis to Conventional Digital Mammography: Effect on Image Interpretation Time of Screening Examinations [J].
Dang, Pragya A. ;
Freer, Phoebe E. ;
Humphrey, Kathryn L. ;
Halpern, Elkan F. ;
Rafferty, Elizabeth A. .
RADIOLOGY, 2014, 270 (01) :49-56
[10]   Dense Breast Ultrasound Screening After Digital Mammography Versus After Digital Breast Tomosynthesis [J].
Dibble, Elizabeth H. ;
Singer, Tisha M. ;
Jimoh, Nneka ;
Baird, Grayson L. ;
Lourenco, Ana P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (06) :1397-1402