Theoretical advantages of a triaxial optically pumped magnetometer magnetoencephalography system

被引:103
作者
Brookes, Matthew J. [1 ]
Boto, Elena [1 ]
Rea, Molly [1 ]
Shah, Vishal [2 ]
Osborne, James [2 ]
Holmes, Niall [1 ]
Hill, Ryan M. [1 ]
Leggett, James [1 ]
Rhodes, Natalie [1 ]
Bowtell, Richard [1 ]
机构
[1] Univ Nottingham, Sir Peter Mansfield Imaging Ctr, Sch Phys & Astron, Univ Pk, Nottingham NG7 2RD, England
[2] QuSpin Inc, 331 South 104th St,Suite 130, Louisville, CO 80027 USA
基金
英国工程与自然科学研究理事会;
关键词
Optically pumped magnetometer; OPM; Magnetoencephalography; MEG; Triaxial sensor; Beamformer; INTERFERENCE; PERFORMANCE; DESIGN;
D O I
10.1016/j.neuroimage.2021.118025
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The optically pumped magnetometer (OPM) is a viable means to detect magnetic fields generated by human brain activity. Compared to conventional detectors (superconducting quantum interference devices) OPMs are small, lightweight, flexible, and operate without cryogenics. This has led to a step change in instrumentation for magnetoencephalography (MEG), enabling a "wearable " scanner platform, adaptable to fit any head size, able to acquire data whilst subjects move, and offering improved data quality. Although many studies have shown the efficacy of 'OPM-MEG', one relatively untapped advantage relates to improved array design. Specifically, OPMs enable the simultaneous measurement of magnetic field components along multiple axes (distinct from a single radial orientation, as used in most conventional MEG systems). This enables characterisation of the magnetic field vector at all sensors, affording extra information which has the potential to improve source reconstruction. Here, we conduct a theoretical analysis of the critical parameters that should be optimised for effective source reconstruction. We show that these parameters can be optimised by judicious array design incorporating triaxial MEG measurements. Using simulations, we demonstrate how a triaxial array offers a dramatic improvement on our ability to differentiate real brain activity from sources of magnetic interference (external to the brain). Further, a triaxial system is shown to offer a marked improvement in the elimination of artefact caused by head movement. Theoretical results are supplemented by an experimental recording demonstrating improved interference reduction. These findings offer new insights into how future OPM-MEG arrays can be designed with improved performance.
引用
收藏
页数:18
相关论文
共 44 条
[1]   High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation [J].
Allred, JC ;
Lyman, RN ;
Kornack, TW ;
Romalis, MV .
PHYSICAL REVIEW LETTERS, 2002, 89 (13) :130801-130801
[2]   Magnetoencephalography for brain electrophysiology and imaging [J].
Baillet, Sylvain .
NATURE NEUROSCIENCE, 2017, 20 (03) :327-339
[3]   Mapping the topological organisation of beta oscillations in motor cortex using MEG [J].
Barratt, Eleanor L. ;
Francis, Susan T. ;
Morris, Peter G. ;
Brookes, Matthew J. .
NEUROIMAGE, 2018, 181 :831-844
[4]  
Borna A, 2017, 20 CHANNEL MAGNETOEN
[5]   Non-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System [J].
Borna, Amir ;
Carter, Tony R. ;
Colombo, Anthony P. ;
Jau, Yuan-Yu ;
McKay, Jim ;
Weisend, Michael ;
Taulu, Samu ;
Stephen, Julia M. ;
Schwindt, Peter D. D. .
PLOS ONE, 2020, 15 (01)
[6]   Measuring functional connectivity with wearable MEG [J].
Boto, Elena ;
Hill, Ryan M. ;
Rea, Molly ;
Holmes, Niall ;
Seedat, Zelekha A. ;
Leggett, James ;
Shah, Vishal ;
Osborne, James ;
Bowtell, Richard ;
Brookes, Matthew J. .
NEUROIMAGE, 2021, 230
[7]   Moving magnetoencephalography towards real-world applications with a wearable system [J].
Boto, Elena ;
Holmes, Niall ;
Leggett, James ;
Roberts, Gillian ;
Shah, Vishal ;
Meyer, Sofie S. ;
Munoz, Leonardo Duque ;
Mullinger, Karen J. ;
Tierney, Tim M. ;
Bestmann, Sven ;
Barnes, Gareth R. ;
Bowtell, Richard ;
Brookes, Matthew J. .
NATURE, 2018, 555 (7698) :657-+
[8]   A new generation of magnetoencephalography: Room temperature measurements using optically-pumped magnetometers [J].
Boto, Elena ;
Meyer, Sofie S. ;
Shah, Vishal ;
Alem, Orang ;
Knappe, Svenja ;
Kruger, Peter ;
Fromhold, T. Mark ;
Lim, Mark ;
Glover, Paul M. ;
Morris, Peter G. ;
Bowtell, Richard ;
Barnes, Gareth R. ;
Brookes, Matthew J. .
NEUROIMAGE, 2017, 149 :404-414
[9]   On the Potential of a New Generation of Magnetometers for MEG: A Beamformer Simulation Study [J].
Boto, Elena ;
Bowtell, Richard ;
Kruger, Peter ;
Fromhold, T. Mark ;
Morris, Peter G. ;
Meyer, Sofie S. ;
Barnes, Gareth R. ;
Brookes, Matthew J. .
PLOS ONE, 2016, 11 (08)
[10]   Cerebral Gray and White Matter Involvement in Anorexia Nervosa Evaluated by T1, T2, and T2*Mapping [J].
Boto, Jose ;
Askin, Nurten Ceren ;
Regnaud, Alice ;
Kober, Tobias ;
Gkinis, Georgios ;
Lazeyras, Francois ;
Loevblad, Karl-Olof ;
Vargas, Maria Isabel .
JOURNAL OF NEUROIMAGING, 2019, 29 (05) :598-604