Removal of malaria-infected red blood cells using magnetic cell separators: A computational study

被引:31
作者
Kim, Jeongho [2 ]
Massoudi, Mehrdad [1 ]
Antaki, James F. [2 ]
Gandini, Alberto [2 ]
机构
[1] US DOE, NETL, Pittsburgh, PA 15236 USA
[2] Carnegie Mellon Univ, Dept Biomed Engn, Pittsburgh, PA 15213 USA
关键词
Cell separator; Red blood cells (RBC); Malaria; Microfluidics; Magnetic forces; Particle trajectory; Micro-channel; MODE MAGNETOPHORETIC MICROSEPARATOR; MACROSCOPIC RIGID SPHERES; EXCHANGE-TRANSFUSION; PLASMODIUM-FALCIPARUM; POISEUILLE FLOW; MIGRATION; GRADIENT; MIXTURE; ADJUNCT; MOTION;
D O I
10.1016/j.amc.2011.12.057
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
High gradient magnetic field separators have been widely used in a variety of biological applications. Recently, the use of magnetic separators to remove malaria-infected red blood cells (pRBCs) from blood circulation in patients with severe malaria has been proposed in a dialysis-like treatment. The capture efficiency of this process depends on many interrelated design variables and constraints such as magnetic pole array pitch, chamber height, and flow rate. In this paper, we model the malaria-infected RBCs (pRBCs) as paramagnetic particles suspended in a Newtonian fluid. Trajectories of the infected cells are numerically calculated inside a micro-channel exposed to a periodic magnetic field gradient. First-order stiff ordinary differential equations (ODEs) governing the trajectory of particles under periodic magnetic fields due to an array of wires are solved numerically using the 1st to 5th order adaptive step Runge-Kutta solver. The numerical experiments show that in order to achieve a capture efficiency of 99% for the pRBCs it is required to have a longer length than 80 mm; this implies that in principle, using optimization techniques the length could be adjusted, i.e., shortened to achieve 99% capture efficiency of the pRBCs. Published by Elsevier Inc.
引用
收藏
页码:6841 / 6850
页数:10
相关论文
共 50 条
  • [41] A three-dimensional quasicontinuum approach for predicting biomechanical properties of malaria-infected red blood cell membrane
    Ademiloye, A. S.
    Zhang, L. W.
    Liew, K. M.
    APPLIED MATHEMATICAL MODELLING, 2017, 49 : 35 - 47
  • [42] Epitopes for modified band 3 monoclonal antibody 1C4 are not exposed on the malaria-infected red blood cell surface
    Hayward, RE
    Day, KP
    MOLECULAR AND BIOCHEMICAL PARASITOLOGY, 2001, 117 (02) : 235 - 239
  • [43] Microvesicles from malaria-infected red blood cells activate natural killer cells via MDA5 pathway
    Ye, Weijian
    Chew, Marvin
    Hou, Jue
    Lai, Fritz
    Leopold, Stije J.
    Loo, Hooi Linn
    Ghose, Aniruddha
    Dutta, Ashok K.
    Chen, Qingfeng
    Ooi, Eng Eong
    White, Nicholas J.
    Dondorp, Arjen M.
    Preiser, Peter
    Chen, Jianzhu
    PLOS PATHOGENS, 2018, 14 (10)
  • [44] Decrease of lymphoid dendritic cells in blood from malaria-infected pregnant women
    Diallo, Mamadou
    Aldebert, Delphine
    Moreau, Jean-Charles
    Ndiaye, Malick
    Jambou, Ronan
    INTERNATIONAL JOURNAL FOR PARASITOLOGY, 2008, 38 (13) : 1557 - 1565
  • [45] An immersed boundary-lattice Boltzmann model for simulation of malaria-infected red blood cell in micro-channel
    Navidbakhsh, M.
    Rezazadeh, M.
    SCIENTIA IRANICA, 2012, 19 (05) : 1329 - 1336
  • [46] Malaria-Infected Red Blood Cell Analysis through Optical and Biochemical Parameters Using the Transport of Intensity Equation and the Microscope's Optical Properties
    Agnero, Marcel Akpa
    Konan, Kouakou
    Tokou, Zan Guy Christian Stephane
    Kossonou, Yao Taky Alvarez
    Dion, Bienvenue Sylvere
    Kaduki, Kenneth Amiga
    Zoueu, Jeremie Thouakesseh
    SENSORS, 2019, 19 (14)
  • [47] Particle Method Simulation of Red Blood Cells Infected by Malaria
    Yamaguchi, Takami
    Kang, Young Ho
    Kondo, Hitoshi
    Imai, Yohsuke
    Ishikawa, Takuji
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 393 - +
  • [48] Red cell selectivity in malaria: a study of multiple-infected erythrocytes
    Simpson, JA
    Silamut, K
    Chotivanich, K
    Pukrittayakamee, S
    White, NJ
    TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 1999, 93 (02) : 165 - 168
  • [49] Rapid and Highly Sensitive Detection of Malaria-Infected Erythrocytes Using a Cell Microarray Chip
    Yatsushiro, Shouki
    Yamamura, Shohei
    Yamaguchi, Yuka
    Shinohara, Yasuo
    Tamiya, Eiichi
    Horii, Toshihiro
    Baba, Yoshinobu
    Kataoka, Masatoshi
    PLOS ONE, 2010, 5 (10):
  • [50] Rapid isolation of single malaria parasite-infected red blood cells by cell sorting
    Miao, Jun
    Cui, Liwang
    NATURE PROTOCOLS, 2011, 6 (02) : 140 - 146