Removal of malaria-infected red blood cells using magnetic cell separators: A computational study

被引:31
|
作者
Kim, Jeongho [2 ]
Massoudi, Mehrdad [1 ]
Antaki, James F. [2 ]
Gandini, Alberto [2 ]
机构
[1] US DOE, NETL, Pittsburgh, PA 15236 USA
[2] Carnegie Mellon Univ, Dept Biomed Engn, Pittsburgh, PA 15213 USA
关键词
Cell separator; Red blood cells (RBC); Malaria; Microfluidics; Magnetic forces; Particle trajectory; Micro-channel; MODE MAGNETOPHORETIC MICROSEPARATOR; MACROSCOPIC RIGID SPHERES; EXCHANGE-TRANSFUSION; PLASMODIUM-FALCIPARUM; POISEUILLE FLOW; MIGRATION; GRADIENT; MIXTURE; ADJUNCT; MOTION;
D O I
10.1016/j.amc.2011.12.057
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
High gradient magnetic field separators have been widely used in a variety of biological applications. Recently, the use of magnetic separators to remove malaria-infected red blood cells (pRBCs) from blood circulation in patients with severe malaria has been proposed in a dialysis-like treatment. The capture efficiency of this process depends on many interrelated design variables and constraints such as magnetic pole array pitch, chamber height, and flow rate. In this paper, we model the malaria-infected RBCs (pRBCs) as paramagnetic particles suspended in a Newtonian fluid. Trajectories of the infected cells are numerically calculated inside a micro-channel exposed to a periodic magnetic field gradient. First-order stiff ordinary differential equations (ODEs) governing the trajectory of particles under periodic magnetic fields due to an array of wires are solved numerically using the 1st to 5th order adaptive step Runge-Kutta solver. The numerical experiments show that in order to achieve a capture efficiency of 99% for the pRBCs it is required to have a longer length than 80 mm; this implies that in principle, using optimization techniques the length could be adjusted, i.e., shortened to achieve 99% capture efficiency of the pRBCs. Published by Elsevier Inc.
引用
收藏
页码:6841 / 6850
页数:10
相关论文
共 50 条
  • [21] Hyaluronic acid binds malaria-infected red blood cells in placenta
    Senior, K
    LANCET, 2000, 355 (9198): : 122 - 122
  • [22] Cytoadherence of malaria-infected red blood cells involves exposure of phosphatidylserine
    Eda, S
    Sherman, IW
    CELLULAR PHYSIOLOGY AND BIOCHEMISTRY, 2002, 12 (5-6) : 373 - 384
  • [23] IMAGING MALARIA-INFECTED RED BLOOD CELLS WITH AFM-IR
    不详
    SPECTROSCOPY, 2018, 33 (10) : 34 - 35
  • [24] On-Chip Impedance Spectroscopy of Malaria-Infected Red Blood Cells
    Panklang, Nitipong
    Techaumnat, Boonchai
    Tanthanuch, Nutthaphong
    Chotivanich, Kesinee
    Horprathum, Mati
    Nakano, Michihiko
    SENSORS, 2024, 24 (10)
  • [25] Osmolyte channels in malaria-infected red cells
    Staines, HM
    Godfrey, EM
    Lapaix, F
    Egée, S
    Thomas, S
    Ellory, JC
    JOURNAL OF PHYSIOLOGY-LONDON, 2002, 539 : 14P - 15P
  • [26] Targeting voracious appetite of malaria-infected red-blood cell
    Pasvol, G
    LANCET, 2001, 357 (9254): : 408 - 410
  • [27] Simulation of malaria-infected red blood cells in microfluidic channels: Passage and blockage
    Wu, Tenghu
    Feng, James J.
    BIOMICROFLUIDICS, 2013, 7 (04):
  • [28] On-chip magnetophoretic capture in a model of malaria-infected red blood cells
    Giacometti, Marco
    Monticelli, Marco
    Piola, Marco
    Milesi, Francesca
    Coppadoro, Lorenzo P.
    Giuliani, Enrico
    Jacchetti, Emanuela
    Raimondi, Manuela T.
    Ferrari, Giorgio
    Antinori, Spinello
    Fiore, Gianfranco B.
    Bertacco, Riccardo
    BIOTECHNOLOGY AND BIOENGINEERING, 2022, 119 (04) : 1129 - 1141
  • [29] Label-free electrochemical detection of malaria-infected red blood cells
    Kumar, Binod
    Bhalla, Vijayender
    Bhadoriya, Ravi Pratap Singh
    Suri, C. Raman
    Varshney, Grish C.
    RSC ADVANCES, 2016, 6 (79): : 75862 - 75869
  • [30] Finite element modeling of the micropipette aspiration of malaria-infected red blood cells
    Zhou, EH
    Lim, CT
    Tan, KSW
    Quek, ST
    Third International Conference on Experimental Mechanics and Third Conference of the Asian-Committee-on-Experimental-Mechanics, Pts 1and 2, 2005, 5852 : 763 - 767