Experimental and numerical study on convective boiling in a staggered array of micro pin-fin microgap

被引:42
作者
Chien, Liang-Han [1 ,2 ]
Cheng, Yi-Ting [1 ,2 ]
Lai, Ying-Liang [1 ,2 ]
Yan, Wei-Mon [1 ,2 ]
Ghalambaz, Mohammad [3 ,4 ]
机构
[1] Natl Taipei Univ Technol, Dept Energy & Refrigerating Air Conditioning Engn, Taipei 10608, Taiwan
[2] Natl Taipei Univ Technol, Res Ctr Energy Conservat New Generat Residential, Taipei 10608, Taiwan
[3] Ton Duc Thang Univ, Dept Management Sci & Technol Dev, Ho Chi Minh City, Vietnam
[4] Ton Duc Thang Univ, Fac Appl Sci, Ho Chi Minh City, Vietnam
关键词
Micro-pin-fin; Staggered array; Microgap; FC-72; Columnar nucleation pin-fin; Nucleate boiling heat transfer; HEAT-TRANSFER; PRESSURE-DROP; MICROCHANNEL; PERFORMANCE; FLUX; CHANNELS; SINKS; FC-72; WATER;
D O I
10.1016/j.ijheatmasstransfer.2019.119203
中图分类号
O414.1 [热力学];
学科分类号
摘要
The flow patterns, heat transfer and pressure drop of convective boiling of dielectric fluid, FC-72, in a micro-gap are investigated experimentally. The surface of the microgap is enhanced with a staggered array of micro pin-fins. The enhanced surface of the microgap with the size of 10 x 10 mm(2) is subject to an electrical heat source. The micro-pin-fins are etched as cubic columns of 100 mu m size and arranged in a staggered arrangement with 400 mu m pitch in both transverse and longitudinal directions. The inside of the micro pin-fins is nucleated with a cavity of cylindrical shape with diameter of 60 mu m and an opening with a size of either 15 mu m or 45 mu m width. The opening of the cavities of the micro-pin-fins is aligned toward the down-stream. For the case of single-phase flow, a numerical analysis is performed, and the pressure drop and velocity fields are investigated in the micro-gap. The experiments were performed for various mass fluxes ranging from 94 to 275 kg/m(2)s and heat flux ranging from 0 to 10 W/cm(2), and at two saturation temperatures of 35 and 50 degrees C. For the case of single-phase heat transfer, the experimental results are compared with the pin-fins having 45 mu m cavity opening and found that the effect of cavity opening is significant when the mass flux is high. The surface-superheat at the onset of boiling is reduced by reducing the cavity opening-width from 45 to 15 mu m. The microgap having nucleation cavity with cavity opening-width of 15 mu m results in a 3.44 degrees C smaller surface-superheat than that of 45 mu m opening-width. The convective heat transfer coefficient increases with the increase of mass flux, regardless of the flow type. Moreover, the variation of the pin-fin opening-widths does not influence the convection heat transfer rate. For single-phase flow, the heat flux shows a negligible effect on pressure drop, and the pressure drop increases with increasing mass flux. For two-phase flow, the pressure drop increases drastically with increasing heat flux. A smaller cavity opening-width results in a smaller pressure drop when the mass flux is high. The flow observation shows two distinct flow patterns in the microgap at the beginning of the bubble nucleation. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:16
相关论文
共 32 条
[1]   Flow boiling of R245fa in a microgap with staggered circular cylindrical pin fins [J].
Asrar, Pouya ;
Zhang, Xuchen ;
Green, Craig E. ;
Bakir, Muhannad ;
Joshi, Yogendra K. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 121 :329-342
[2]   FLOW BOILING OF R134a IN A LARGE SURFACE AREA MICROCHANNEL ARRAY FOR HIGH-FLUX LASER DIODE COOLING [J].
Bevis, Taylor ;
Burk, Bryan ;
Hoke, Jensen ;
Kotovsky, Jack ;
Hamilton, Julie ;
Bandhauer, Todd .
HEAT TRANSFER RESEARCH, 2019, 50 (14) :1417-1436
[3]  
Carey V.P., 2020, Liquid-Vapor Phase-Change Phenomena: An Introduction to the Thermophysics of Vaporization and Condensation Processes in Heat Transfer Equipment, Vthird
[4]   Experimental study on convective boiling flow and heat transfer in a microgap enhanced with a staggered arrangement of nucleated micro-pin-fins [J].
Chien, Liang-Han ;
Liao, Wun-Rong ;
Ghalambaz, Mohammad ;
Yan, Wei-Mon .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 144
[5]   Experimental study on convective boiling of micro-pin-finned channels with parallel arrangement fins for FC-72 dielectric fluid [J].
Chien, Liang-Han ;
Liao, Wun-Rong ;
Ghalambaz, Mohammad ;
Yan, Wei-Mon .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 138 :390-400
[6]   Flow boiling performance in pin fin- interconnected reentrant microchannels heat sink in different operational conditions [J].
Deng, Daxiang ;
Chen, Liang ;
Wan, Wei ;
Fu, Ting ;
Huang, Xiang .
APPLIED THERMAL ENGINEERING, 2019, 150 :1260-1272
[7]   Flow boiling critical heat flux of DI-water and nanofluids inside smooth and nanoporous round microchannels [J].
do Nascimento, Francisco Julio ;
Moreira, Tiago Augusto ;
Ribatski, Gherhardt .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 139 :240-253
[8]   Two-phase operational maps, pressure drop, and heat transfer for flow boiling of R236fa in a micro-pin fin evaporator [J].
Falsetti, C. ;
Jafarpoorchekab, H. ;
Magnini, M. ;
Borhani, N. ;
Thome, J. R. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 107 :805-819
[9]  
Hsieh S.-S., 2009, J MICROMECH MICROENG, V20
[10]   Pressure drop, boiling heat transfer and flow patterns during flow boiling in a single microchannel [J].
Huh, Cheol ;
Kim, Moo Hwan . .