Bispectral analysis of the electroencephalogram: a review of its development and use in anesthesia

被引:66
作者
March, PA [1 ]
Muir, WW [1 ]
机构
[1] Ohio State Univ, Coll Vet Med, Dept Vet Clin Sci, Columbus, OH 43210 USA
关键词
anesthesia; bispectral index; electroencephalography; isoflurane; minimum alveolar concentration;
D O I
10.1111/j.1467-2995.2005.00221.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To evaluate the different methodologies used to monitor anesthetic depth and to review the principles and potential applications of bispectral index (BIS) monitoring in veterinary anesthesia. Databases used Medline (1966 to present); Pubmed (mid-1960s to present); personal files. Conclusions Current anesthetic monitoring techniques rely on indirect measures of corticocerebral arousal after a noxious stimulus. Some anesthetics and pre-anesthetics suppress responses that are used to gauge adequate hypnosis and analgesia. The BIS is a direct measure of corticocerebral activation and is inversely related to the degree of hypnosis. Dynamic changes in the BIS after a noxious stimulus may signify early nociceptive activation of the cerebral cortex and may be a useful marker of inadequate analgesia. However, application of this technique during the use of various drug combinations (i.e. clinical anesthesia) will require further research and understanding.
引用
收藏
页码:241 / 255
页数:15
相关论文
共 80 条
[61]   The effect of ketamine on clinical endpoints of hypnosis and EEG variables during propofol infusion [J].
Sakai, T ;
Singh, H ;
Mi, WD ;
Kudo, T ;
Matsuki, A .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1999, 43 (02) :212-216
[62]   Pretreatment with dexmedetomidine: Altered indices of anesthetic depth for halothane in the neuraxis of cats [J].
Schmeling, WT ;
Ganjoo, P ;
Staunton, M ;
Drexler, C ;
Farber, NE .
ANESTHESIA AND ANALGESIA, 1999, 88 (03) :625-632
[63]  
SEBEL PS, 1991, ANESTHESIOLOGY, V75, pA446
[64]  
SHORT CE, 1996, LUMB JONES VET ANEST, P148
[65]   AN INTRODUCTION TO BISPECTRAL ANALYSIS FOR THE ELECTROENCEPHALOGRAM [J].
SIGL, JC ;
CHAMOUN, NG .
JOURNAL OF CLINICAL MONITORING, 1994, 10 (06) :392-404
[66]   Movement response to skin incision: analgesia vs. bispectral index and 95% spectral edge frequency [J].
Singh, H ;
Sakai, T ;
Matsuki, A .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1999, 16 (09) :610-614
[67]   Titration of volatile anesthetics using bispectral index facilitates recovery after ambulatory anesthesia [J].
Song, DJ ;
Joshi, GP ;
White, PF .
ANESTHESIOLOGY, 1997, 87 (04) :842-848
[68]  
STANSKI DR, 2000, ANESTHESIA, V1, P1087
[69]  
STEFFEY EP, 1977, AM J VET RES, V38, P1833
[70]  
STEFFEY EP, 1996, LUMB JONES VET ANEST, P297