Current Status of Serum Insulin and C-Peptide Measurement in Clinical Laboratories: Experience from 94 Laboratories in China

被引:6
作者
Zhou, Weiyan [1 ]
Deng, Yuhang [1 ,2 ]
Zhao, Haijian [1 ]
Zhang, Chuanbao [1 ]
机构
[1] Beijing Hosp, Chinese Acad Med Sci, Natl Ctr Clin Labs, Natl Ctr Gerontol,Inst Geriatr Med,Beijing Engn R, 1 Dahua Rd, Beijing 100730, Peoples R China
[2] Peking Union Med Coll, Beijing, Peoples R China
基金
北京市自然科学基金;
关键词
C-peptide; Insulin; Harmonization; Standardization; Diabetes mellitus; ISOTOPE-DILUTION; STANDARDIZATION; IMMUNOASSAYS; CHROMATOGRAPHY; PREVALENCE;
D O I
10.3343/alm.2022.42.4.428
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Accurate measurements of serum insulin and C-peptide are needed for the therapy and classification of diabetes. This study investigated the status of serum insulin and C-peptide measurements in China by analyzing the results of five pooled serum samples measured in 94 laboratories. Methods: Patient serum samples were pooled into five groups according to insulin and C peptide concentrations and measured in 94 laboratories using different measurement systems. The inter-and intra-laboratory %CV as well as inter-and intra-measurement system %CV were calculated to assess the status of insulin and C-peptide measurements. To verify whether the disagreement between laboratories was due to different calibrators, as reported in previous studies, one low-level and one high-level sample extracted from the five pooled serum samples were used to recalibrate clinical measurement systems. Results: The mean intra-laboratory, intra-measurement system, inter-laboratory, and inter measurement system %CVs were 2.7%, 4.8%, 21.8%, and 22.4%, respectively, for insulin and 2.3%, 6.7%, 16.4%, and 24.5%, respectively, for C-peptide. The inter-and intralaboratory %CVs for insulin decreased with increasing concentration. After recalibration with low-and high-level samples, the mean inter-measurement %CV decreased from 22.4% to 17.2% for insulin and from 24.5% to 5.7% for C-peptide. Conclusions: The intra-laboratory and intra-measurement system imprecision values are satisfactory for serum insulin and C-peptide measurements. However, the results from laboratories using different measurement systems were not comparable, and there is still much work needed to achieve the standardization or harmonization of serum insulin and C-peptide measurements.
引用
收藏
页码:428 / +
页数:11
相关论文
共 21 条
  • [1] Global estimates of diabetes prevalence for 2013 and projections for 2035
    Guariguata, L.
    Whiting, D. R.
    Hambleton, I.
    Beagley, J.
    Linnenkamp, U.
    Shaw, J. E.
    [J]. DIABETES RESEARCH AND CLINICAL PRACTICE, 2014, 103 (02) : 137 - 149
  • [2] Harmonization of immunoassays for biomarkers in diabetes mellitus
    Hoerber, Sebastian
    Achenbach, Peter
    Schleicher, Erwin
    Peter, Andreas
    [J]. BIOTECHNOLOGY ADVANCES, 2020, 39
  • [3] The clinical utility of C-peptide measurement in the care of patients with diabetes
    Jones, A. G.
    Hattersley, A. T.
    [J]. DIABETIC MEDICINE, 2013, 30 (07) : 803 - 817
  • [4] Quantification of serum C-peptide by isotope-dilution liquid chromatography-tandem mass spectrometry: Enhanced detection using chemical modification and immunoaffinity purification
    Kinumi, Tomoya
    Mizuno, Ryoko
    Takatsu, Akiko
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 953 : 138 - 142
  • [5] Development of SI-traceable C-peptide certified reference material NMIJ CRM 6901-a using isotope-dilution mass spectrometry-based amino acid analyses
    Kinumi, Tomoya
    Goto, Mari
    Eyama, Sakae
    Kato, Megumi
    Kasama, Takeshi
    Takatsu, Akiko
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (01) : 13 - 21
  • [6] A Practical Review of C-Peptide Testing in Diabetes
    Leighton, Emma
    Sainsbury, Christopher A. R.
    Jones, Gregory C.
    [J]. DIABETES THERAPY, 2017, 8 (03) : 475 - 487
  • [7] Little, 2021 C PEPT STAND MA
  • [8] Standardization of C-peptide measurements
    Little, Randie R.
    Rohlfing, Curt L.
    Tennill, Alethea L.
    Madsen, Richard W.
    Polonsky, Kenneth S.
    Myers, Gary L.
    Greenbaum, Carla J.
    Palmer, Jerry P.
    Rogatsky, Eduard
    Stein, Daniel T.
    [J]. CLINICAL CHEMISTRY, 2008, 54 (06) : 1023 - 1026
  • [9] Implementing a Reference Measurement System for C-Peptide: Successes and Lessons Learned
    Little, Randie R.
    Wielgosz, Robert I.
    Josephs, Ralf
    Kinumi, Tomoya
    Takatsu, Akiko
    Li, Hongmei
    Stein, Daniel
    Burns, Chris
    [J]. CLINICAL CHEMISTRY, 2017, 63 (09) : 1447 - 1456
  • [10] Comparison of 11 human insulin assays: Implications for clinical investigation and research
    Manley, Susan E.
    Stratton, Irene M.
    Clark, Penelope M.
    Luzio, Stephen D.
    [J]. CLINICAL CHEMISTRY, 2007, 53 (05) : 922 - 932