Hot-Water Distribution System Piping Time, Water, and Energy Waste-Phase III: Test Results

被引:0
|
作者
Hiller, Carl C. [1 ]
机构
[1] Appl Energy Technol Co, Davis, CA USA
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper describes results of recent laboratory tests on additional common hot-water distribution system piping sizes and types under a variety of flow rate, temperature, and environmental conditions. The new tests include chlorinated polyvinyl chloride (CPVC) and high-density cross-linked polyethylene (PEX) piping. They also include attic and floor environments. The tests measured the time spent waiting for hot water to arrive at fixtures and the amount of water wasted to drain while waiting. From these, the energy waste associated with the water waste can be computed. Results are presented as plots of the ratio of actual flow volume divided by pipe volume (AF/PV) vs. flow rate, temperatures, and other parameters of importance. Several unanticipated flow regimes were observed that dramatically alter behavior from what might be expected based on either plug-flow or fully developed flow theory. A separate related paper discusses piping heat loss UA factors that were measured.
引用
收藏
页码:742 / 754
页数:13
相关论文
共 50 条
  • [31] Research progress of phase change energy storage in solar domestic hot water system
    Luo K.
    Ye W.
    Wang Y.
    Zeng Z.
    Liu J.
    Fei H.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (05): : 220 - 229
  • [32] Energy Saving and Economic Evaluations of Exhaust Waste Heat Recovery Hot Water Supply System for Resort
    Nguyen, Nghia-Huu
    Lee, Dong-Yeon
    Garud, Kunal Sandip
    Lee, Moo-Yeon
    SYMMETRY-BASEL, 2021, 13 (04):
  • [33] PREDICTIVE CONTROL BY NEURAL NETWORK OF HOT-WATER FLOOR HEATING SYSTEM WITH SHEET PHASE CHANGE MATERIAL INTO THE FLOOR OF RC APARTMENT HOUSE
    Takane Y.
    Takamura H.
    Journal of Environmental Engineering (Japan), 2023, 88 (810): : 649 - 657
  • [34] Optimal control of a heat pump-based energy system for space heating and hot water provision in buildings: Results from a field test
    Mbuwir, Brida V.
    Geysen, Davy
    Kosmadakis, George
    Pilou, Marika
    Meramveliotakis, George
    Toersche, Hermen
    ENERGY AND BUILDINGS, 2024, 310
  • [35] A New Method of Near Real-Time Monitoring of Residential Hot Water Distribution System Performance
    Lutz, J. D.
    ASHRAE TRANSACTIONS 2014, VOL 120, PT 2, 2014, 120
  • [36] A case report of false negative Legionella test results in a chlorinated public hot water distribution system due to the lack of sodium thiosulfate in sampling bottles
    Wiedenmann, A
    Langhammer, W
    Botzenhart, K
    INTERNATIONAL JOURNAL OF HYGIENE AND ENVIRONMENTAL HEALTH, 2001, 204 (04) : 245 - 249
  • [37] Experimental test of a hot water storage system including a macro-encapsulated phase change material (PCM)
    Mongibello, L.
    Atrigna, M.
    Bianco, N.
    Di Somma, M.
    Graditi, G.
    Risi, N.
    34TH UIT HEAT TRANSFER CONFERENCE 2016, 2017, 796
  • [38] Modelling transient temperature distribution for injecting hot water through a well to an aquifer thermal energy storage system
    Yang, Shaw-Yang
    Yeh, Hund-Der
    Li, Kuang-Yi
    GEOPHYSICAL JOURNAL INTERNATIONAL, 2010, 183 (01) : 237 - 251
  • [39] Estimation of the energy-saving effect of introducing a heat source water network system with single-loop piping utilizing hot spring heat
    Nabeshima, Minako
    Koh, Naoyoshi
    Naka, Masaki
    Mike, Masahito
    16TH INTERNATIONAL SYMPOSIUM ON DISTRICT HEATING AND COOLING, DHC2018, 2018, 149 : 519 - 528
  • [40] Charging performance of latent thermal energy storage system with microencapsulated phase-change material for domestic hot water
    Fang, Y.
    Qu, Z. G.
    Zhang, J. F.
    Xu, H. T.
    Qi, G. L.
    ENERGY AND BUILDINGS, 2020, 224