Development of The Data Acquisition System for The 32-Channel Electrical Capacitance Volume Tomography

被引:0
作者
Yusuf, Arba'i [1 ]
Widada, Wahyu [2 ]
Warsito, W. [3 ]
机构
[1] Indonesian Natl Inst Aeronaut & Space, Ctr Satellite Technol, Bogor, Indonesia
[2] Indonesian Natl Inst Aeronaut & Space, Ctr Rocket Technol, Bogor, Indonesia
[3] Univ Indonesia, Dept Phys, Depok, Indonesia
来源
2011 IEEE REGION 10 CONFERENCE TENCON 2011 | 2011年
关键词
ECVT; CMOS switch; tomography; resolution; image reconstruction; DESIGN;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Electrical Capacitance Volume Tomography (ECVT) is one of three- dimensional image visualization method using capacitance effect. This paper describes a data acquisition system for 32-channel electrical capacitance volume tomography base on CMOS switch technology and charge- discharge system. results show the data acquisition system capable to measure of a novel capacitance with 0.21 fF to 0.42 fF resolution. this system are four frames per second for 32 channels.
引用
收藏
页码:326 / 329
页数:4
相关论文
共 50 条
[41]   Mobile Electrical Capacitance Tomography (ECT) Development for LiquidGas Flow Measurement [J].
Seong, Chan Kok ;
Pusppanathan, Jaysuman ;
Rahim, Ruzairi Abdul ;
Susiapan, Yvette Shaan-Li ;
Phang, Fatin Aliah ;
Rahiman, Mohd Hafiz Fazalul ;
Awang, Zubaidah ;
Ahmad, Anita ;
Wahid, Herman Abdul ;
Mohamad, Elmy Johana ;
Aw, Suzanna Ridzuan .
JURNAL TEKNOLOGI, 2015, 73 (03)
[42]   Investigation of water ingress into uncracked and cracked cement-based materials using electrical capacitance volume tomography [J].
Wang, Wentao ;
Zhao, Kaiyue ;
Zhang, Peng ;
Bao, Jiuwen ;
Xue, Shanbin .
MATERIALS & DESIGN, 2022, 220
[43]   Preliminary Study for the Implementation of Electrical Capacitance Volume Tomography (ECVT) to Display Fruit Content [J].
Agustiansyah, Riza ;
Saedudin, Rohmat ;
Al Huda, Mahfudz .
RECENT ADVANCES ON SOFT COMPUTING AND DATA MINING, 2017, 549 :285-293
[44]   Electrical Capacitance Volume Tomography Validation of Column Flotation Process with Gas Injection Variation [J].
Harjanto, Sri ;
Haryono, Didied ;
Faisal, Hermansyah Emir ;
Daniah, Kholis ;
Nugraha, Harisma ;
Al Huda, Mahfudz ;
Taruno, Warsito P. .
ENGINEERING JOURNAL-THAILAND, 2018, 22 (01) :215-227
[45]   Electrical capacitance volume tomography with high contrast dielectrics using a cuboid sensor geometry [J].
Nurge, Mark A. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (05) :1511-1520
[46]   Acceleration of Electrical Capacitance Volume Tomography Imaging by Fourier-Based Sparse Representations [J].
Gunes, Cagdas ;
Acero, Daniel Ospina ;
Marashdeh, Qussai M. ;
Teixeira, Fernando L. .
IEEE SENSORS JOURNAL, 2018, 18 (23) :9649-9659
[47]   Reduced-Space Relevance Vector Machine for Adaptive Electrical Capacitance Volume Tomography [J].
Acero, Daniel Ospina ;
Marashdeh, Qussai M. ;
Teixeira, Fernando L. .
IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2022, 8 :41-53
[48]   Visualization of flow structures inside a conical spouted bed by electrical capacitance volume tomography [J].
Park, Hoon Chae ;
Choi, Hang Seok .
PARTICUOLOGY, 2019, 42 :15-25
[49]   Analyses and simulation of sensor structure parameters for electrical capacitance tomography system [J].
Chen Deyun ;
Wang Lili ;
Chen Yu .
INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2007: PHOTOELECTRONIC IMAGING AND DETECTION, 2008, 6621
[50]   Trust Region Algorithm for Image Reconstruction in Electrical Capacitance Tomography System [J].
Wang Lili ;
Chen Yu ;
Chen Deyun ;
Yu Xiaoyang .
2011 INTERNATIONAL CONFERENCE ON COMPUTER SCIENCE AND NETWORK TECHNOLOGY (ICCSNT), VOLS 1-4, 2012, :204-209