Internal fit of three-unit fixed dental prostheses produced by computer-aided design/computer-aided manufacturing and the lost-wax metal casting technique assessed using the triple-scan protocol

被引:17
作者
Dahl, Bjorn E. [1 ]
Dahl, Jon E. [2 ,3 ]
Ronold, Hans J. [1 ]
机构
[1] Univ Oslo, Fac Dent, Inst Clin Dent, Dept Prosthet Dent, POB 1109 Blindern, NO-0317 Oslo, Norway
[2] Univ Oslo, Fac Dent, Inst Clin Dent, Oslo, Norway
[3] NIOM Nord Inst Dent Mat, Oslo, Norway
关键词
CAD; CAM; cement space; dental crown; lithium disilicate glass-ceramic; zirconium dioxide; MARGINAL ADAPTATION; CERAMIC CROWNS; IN-VITRO; MICRO-CT; CEMENT; IMPRESSIONS; RELIABILITY; TECHNOLOGY; THICKNESS; COPINGS;
D O I
10.1111/eos.12394
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Suboptimal adaptation of fixed dental prostheses (FDPs) can lead to technical and biological complications. It is unclear if the computer-aided design/computer-aided manufacturing (CAD/CAM) technique improves adaptation of FDPs compared with FDPs made using the lost-wax and metal casting technique. Three-unit FDPs were manufactured by CAD/CAM based on digital impression of a typodont model. The FDPs were made from one of five materials: pre-sintered zirconium dioxide; hot isostatic pressed zirconium dioxide; lithium disilicate glass-ceramic; milled cobalt-chromium; and laser-sintered cobalt-chromium. The FDPs made using the lost-wax and metal casting technique were used as reference. The fit of the FDPs was analysed using the triple-scan method. The fit was evaluated for both single abutments and three-unit FDPs. The average cement space varied between 50 m and 300 m. Insignificant differences in internal fit were observed between the CAD/CAM-manufactured FDPs, and none of the FPDs had cement spaces that were statistically significantly different from those of the reference FDP. For all FDPs, the cement space at a marginal band 0.5-1.0 mm from the preparation margin was less than 100 m. The milled cobalt-chromium FDP had the closest fit. The cement space of FDPs produced using the CAD/CAM technique was similar to that of FDPs produced using the conventional lost-wax and metal casting technique.
引用
收藏
页码:66 / 73
页数:8
相关论文
共 19 条
[1]   Comparison of the marginal fit of lithium disilicate crowns fabricated with CAD/CAM technology by using conventional impressions and two intraoral digital scanners [J].
Abdel-Azim, Tamer ;
Rogers, Kelly ;
Elathamna, Eiad ;
Zandinejad, Amirali ;
Metz, Michael ;
Morton, Dean .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (04) :554-559
[2]   Assessment of the Internal Fit of Lithium Disilicate Crowns Using Micro-CT [J].
Alfaro, David P. ;
Ruse, N. Dorin ;
Carvalho, Ricardo M. ;
Wyatt, Chris C. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2015, 24 (05) :381-386
[3]  
Contrepois M, 2013, J PROSTHET DENT, V110, P447, DOI 10.1016/j.prosdent.2013.08.003
[4]   Internal fit of single crowns produced by CAD-CAM and lost-wax metal casting technique assessed by the triple-scan protocol [J].
Dahl, Bjorn Einar ;
Ronold, Hans Jacob ;
Dahl, Jon E. .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (03) :400-404
[5]   To what extent does the longevity of fixed dental prostheses depend on the function of the cement?: Working Group 4 materials:: cementation [J].
Edelhoff, Daniel ;
Ozcan, Mutlu .
CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 :193-204
[6]   Reliability of the Impression Replica Technique [J].
Falk, Anders ;
von Steyern, Per Vult ;
Franssori, Hakan ;
Thoren, Margareta Molin .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (02) :179-180
[7]   Tooth preparations for complete crowns: An art form based on scientific principles [J].
Goodacre, CJ ;
Campagni, WV ;
Aquilino, SA .
JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (04) :363-376
[8]  
Holst S, 2011, QUINTESSENCE INT, V42, P651
[9]  
Matta RE, 2012, QUINTESSENCE INT, V43, P801
[10]   Precision of fit: The Procera AllCeram crown [J].
May, KB ;
Russell, MM ;
Razzoog, ME ;
Lang, BR .
JOURNAL OF PROSTHETIC DENTISTRY, 1998, 80 (04) :394-404