Long-term evaluation of sandblasted and acid-etched implants used as orthodontic anchors in dogs

被引:27
作者
Aldikaçti, M
Açikgöz, G
Türk, T
Trisi, P
机构
[1] Univ Ondokuz Mayis, Fac Dent, Dept Orthodont, TR-55139 Kurupelit, Turkey
[2] Univ Ondokuz Mayis, Fac Dent, Dept Orthodont, TR-55139 Kurupelit, Turkey
关键词
D O I
10.1016/S0889-5406(03)00629-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was the clinical, radiographic, and histologic evaluation of the tissue surrounding SLA (sandblasted and acid-etched) implants loaded with a continuous and constant force for 52 weeks, after a healing period of 6 weeks, after implant insertion. SLA implants were placed in the maxilla of 3 dogs and the mandible of 5 dogs after a 12-week healing period after extraction. Abutments were attached to the 6 test implants (2 in the maxilla, 4 in the mandible). Superelastic nickel-titanium coil springs were activated between the SLA implants and the canines, producing a force of 200 g (2 N). Two unloaded implants (1 in the maxilla, 1 in the mandible) served as controls. Histologic analysis showed a corticalization of bone trabeculae, thicker at the loaded than at the unloaded implants. New bone formation at the level of the crest was slightly superior in the test implants. A difference between the tension and compression areas could not be observed in the test implants. The mean bone-implant contact values of the test implants for the maxilla and mandible were 40.23% and 49.33%, respectively. In the control implants, the bone-implant contact value was 67.91% for the maxilla and 49.23% for the mandible. SLA implants can be used as an anchorage unit with confidence, in spite of a short healing period and a prolonged force application. Further studies with different force magnitudes and healing periods are required to clarify the effects of healing period and force magnitude on bone quality and quantity.
引用
收藏
页码:139 / 147
页数:9
相关论文
共 29 条
[1]   Reactions of peri-implant tissues to continuous loading of osseointegrated implants [J].
Akin-Nergiz, N ;
Nergiz, I ;
Schulz, A ;
Arpak, N ;
Niedermeier, W .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1998, 114 (03) :292-298
[2]   INFLUENCE OF SURFACE CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANTS - A HISTOMORPHOMETRIC STUDY IN MINIATURE PIGS [J].
BUSER, D ;
SCHENK, RK ;
STEINEMANN, S ;
FIORELLINI, JP ;
FOX, CH ;
STICH, H .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07) :889-902
[3]   The original one-stage dental implant system and its clinical application [J].
Buser, D ;
Belser, UC ;
Lang, NP .
PERIODONTOLOGY 2000, 1998, 17 :106-118
[4]   Evaluation of an endosseous titanium implant with a sandblasted and acid-etched surface in the canine mandible: Radiographic results [J].
Cochran, DL ;
Nummikoski, PV ;
Higginbottom, FL ;
Hermann, JS ;
Makins, SR ;
Buser, D .
CLINICAL ORAL IMPLANTS RESEARCH, 1996, 7 (03) :240-252
[5]  
Cochran DL, 1998, J BIOMED MATER RES, V40, P1, DOI 10.1002/(SICI)1097-4636(199804)40:1<1::AID-JBM1>3.0.CO
[6]  
2-Q
[7]   A METHOD FOR THE STUDY OF UNDECALCIFIED BONES AND TEETH WITH ATTACHED SOFT-TISSUES - THE SAGE-SCHLIFF (SAWING AND GRINDING) TECHNIQUE [J].
DONATH, K ;
BREUNER, G .
JOURNAL OF ORAL PATHOLOGY & MEDICINE, 1982, 11 (04) :318-326
[8]   STUDIES ON THE EFFICACY OF IMPLANTS AS ORTHODONTIC ANCHORAGE [J].
GRAY, JB ;
STEEN, ME ;
KING, GJ ;
CLARK, AE .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1983, 83 (04) :311-317
[9]   THE EFFICACY OF 2-STAGE TITANIUM IMPLANTS AS ORTHODONTIC ANCHORAGE IN THE PREPROSTHODONTIC CORRECTION OF 3RD MOLARS IN ADULTS - A REPORT OF 3 CASES [J].
HAANAES, HR ;
STENVIK, A ;
BEYEROLSEN, ES ;
TRYTI, T ;
FAEHN, O .
EUROPEAN JOURNAL OF ORTHODONTICS, 1991, 13 (04) :287-292
[10]   TITANIUM IMPLANT ANCHORAGE IN ORTHODONTIC TREATMENT - AN EXPERIMENTAL INVESTIGATION IN MONKEYS [J].
LINDERARONSON, S ;
NORDENRAM, A ;
ANNEROTH, G .
EUROPEAN JOURNAL OF ORTHODONTICS, 1990, 12 (04) :414-419