Locomotion of Sensor-Integrated Soft Robotic Devices Inside Sub-Millimeter Arteries with Impaired Flow Conditions

被引:14
作者
Pancaldi, Lucio [1 ,2 ]
Noseda, Lorenzo [1 ,2 ]
Dolev, Amit [1 ,2 ]
Fanelli, Adele [3 ,4 ]
Ghezzi, Diego [3 ,4 ]
Petruska, Andrew J. [5 ]
Sakar, Mahmut Selman [1 ,2 ]
机构
[1] Ecole Polytech Fed Lausanne, Inst Mech Engn, CH-1015 Lausanne, Switzerland
[2] Ecole Polytech Fed Lausanne, Inst Bioengn, CH-1015 Lausanne, Switzerland
[3] Ctr Neuroprosthet, Medtron Chair Neuroengn, CH-1202 Geneva, Switzerland
[4] Inst Bioengn, CH-1202 Geneva, Switzerland
[5] Colorado Sch Mines, Mech Engn Dept, Golden, CO 80401 USA
基金
欧洲研究理事会;
关键词
endovascular interventions; magnetism; medical imaging; medical robotics; microengineering; solid mechanics; GUIDEWIRE; ABLATION;
D O I
10.1002/aisy.202100247
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
One of the grand challenges in interventional cardiology and neuroradiology is to minimize the operation time and risk of damage during catheterization. These two factors drastically increase if the target location resides in small and tortuous vessels. Flow-driven microcatheters are capable of rapidly and safely navigating small arteries with complex anatomy. However, their navigation relies on proper perfusion, which is an important bottleneck in the treatment of pathologies that cause impaired flow conditions. This work introduces the first endovascular sensor-integrated soft robotic device that navigates sub-millimeter arteries by extracting propulsive power from external magnetic fields. To this end, a number of innovations are described in the design, actuation, and control of flexible magnetic structures. The device is capable of advancing inside vasculature in an automated fashion using an open-loop control scheme. Onboard sensors enable the real-time monitoring of flow conditions, and autonomous switching between different modes of locomotion. The potential of the presented technology for minimally invasive diagnosis and therapy is demonstrated by achieving navigation inside coronary arteries of an ex vivo porcine heart under fluoroscopic guidance.
引用
收藏
页数:10
相关论文
共 51 条
  • [1] Abbott JJ, 2020, ANNU REV CONTR ROBOT, V3, P57, DOI [10.1146/annurev-control-081219-082713, 10.1146/annurev-control-081219082713]
  • [2] Parametric design of tri-axial nested Helmholtz coils
    Abbott, Jake J.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (05)
  • [3] Self-sufficient self-oscillating microsystem driven by low power at low Reynolds numbers
    Akbar, Farzin
    Rivkin, Boris
    Aziz, Azaam
    Becker, Christian
    Karnaushenko, Dmitriy D.
    Medina-Sanchez, Mariana
    Karnaushenko, Daniil
    Schmidt, Oliver G.
    [J]. SCIENCE ADVANCES, 2021, 7 (44)
  • [4] Using the fringe field of a clinical MRI scanner enables robotic navigation of tethered instruments in deeper vascular regions
    Azizi, Arash
    Tremblay, Charles C.
    Gagne, Kevin
    Martel, Sylvain
    [J]. SCIENCE ROBOTICS, 2019, 4 (36)
  • [5] Continuum Robots for Medical Applications: A Survey
    Burgner-Kahrs, Jessica
    Rucker, D. Caleb
    Choset, Howie
    [J]. IEEE TRANSACTIONS ON ROBOTICS, 2015, 31 (06) : 1261 - 1280
  • [6] Chatzipirpiridis G, 2015, 2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), P1727, DOI 10.1109/TRANSDUCERS.2015.7181278
  • [7] Magnetic Continuum Device with Variable Stiffness for Minimally Invasive Surgery
    Chautems, Christophe
    Tonazzini, Alice
    Boehler, Quentin
    Jeong, Seung Hee
    Floreano, Dario
    Nelson, Bradley J.
    [J]. ADVANCED INTELLIGENT SYSTEMS, 2020, 2 (06)
  • [8] Formula for the viscosity of a glycerol-water mixture
    Cheng, Nian-Sheng
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2008, 47 (09) : 3285 - 3288
  • [9] Endovascular Advances for Brain Arteriovenous Malformations
    Crowley, R. Webster
    Ducruet, Andrew F.
    McDougall, Cameron G.
    Albuquerque, Felipe C.
    [J]. NEUROSURGERY, 2014, 74 : S74 - S82
  • [10] D'Amico RS, 2020, J NEURO-ONCOL, V147, P261, DOI 10.1007/s11060-020-03435-6