A novel crystal-analyzer phase retrieval algorithm and its noise property

被引:8
作者
Bao, Yuan [1 ,2 ]
Wang, Yan [2 ]
Li, Panyun [2 ]
Wu, Zhao [1 ]
Shao, Qigang [1 ]
Gao, Kun [1 ]
Wang, Zhili [1 ]
Ju, Zaiqiang [2 ]
Zhang, Kai [2 ]
Yuan, Qingxi [2 ]
Huang, Wanxia [2 ]
Zhu, Peiping [1 ,2 ,3 ]
Wu, Ziyu [1 ,2 ]
机构
[1] Univ Sci & Technol China, Natl Synchrotron Radiat Lab, Hefei 230029, Anhui, Peoples R China
[2] Chinese Acad Sci, Inst High Energy Phys, Beijing 100049, Peoples R China
[3] Beijing Ctr Math & Informat Interdisciplinary Sci, Beijing 100048, Peoples R China
基金
中国国家自然科学基金;
关键词
diffraction enhanced imaging; phase retrieval; noise in imaging systems; X-RAY PHASE; IMAGING PERFORMANCE; CONTRAST; ABSORPTION; REFRACTION; SCATTERING; SPECTRUM;
D O I
10.1107/S1600577515003616
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A description of the rocking curve in diffraction enhanced imaging (DEI) is presented in terms of the angular signal response function and a simple multi-information retrieval algorithm based on the cosine function fitting. A comprehensive analysis of noise properties of DEI is also given considering the noise transfer characteristic of the X-ray source. The validation has been performed with synchrotron radiation experimental data and Monte Carlo simulations based on the Geant4 toolkit combined with the refractive process of X-rays, which show good agreement with each other. Moreover, results indicate that the signal-to-noise ratios of the refraction and scattering images are about one order of magnitude better than that of the absorption image at the edges of low-Z samples. The noise penalty is drastically reduced with the increasing photon flux and visibility. Finally, this work demonstrates that the analytical method can build an interesting connection between DEI and GDPCI (grating-based differential phase contrast imaging) and is widely suitable for a variety of measurement noise in the angular signal response imaging prototype. The analysis significantly contributes to the understanding of noise characteristics of DEI images and may allow improvements to the signal-to-noise ratio in biomedical and material science imaging.
引用
收藏
页码:786 / 795
页数:10
相关论文
共 47 条
  • [1] GEANT4-a simulation toolkit
    Agostinelli, S
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Arce, P
    Asai, M
    Axen, D
    Banerjee, S
    Barrand, G
    Behner, F
    Bellagamba, L
    Boudreau, J
    Broglia, L
    Brunengo, A
    Burkhardt, H
    Chauvie, S
    Chuma, J
    Chytracek, R
    Cooperman, G
    Cosmo, G
    Degtyarenko, P
    Dell'Acqua, A
    Depaola, G
    Dietrich, D
    Enami, R
    Feliciello, A
    Ferguson, C
    Fesefeldt, H
    Folger, G
    Foppiano, F
    Forti, A
    Garelli, S
    Giani, S
    Giannitrapani, R
    Gibin, D
    Cadenas, JJG
    González, I
    Abril, GG
    Greeniaus, G
    Greiner, W
    Grichine, V
    Grossheim, A
    Guatelli, S
    Gumplinger, P
    Hamatsu, R
    Hashimoto, K
    Hasui, H
    Heikkinen, A
    Howard, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) : 250 - 303
  • [2] Geant4 developments and applications
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Dubois, PA
    Asai, M
    Barrand, G
    Capra, R
    Chauvie, S
    Chytracek, R
    Cirrone, GAP
    Cooperman, G
    Cosmo, G
    Cuttone, G
    Daquino, GG
    Donszelmann, M
    Dressel, M
    Folger, G
    Foppiano, F
    Generowicz, J
    Grichine, V
    Guatelli, S
    Gumplinger, P
    Heikkinen, A
    Hrivnacova, I
    Howard, A
    Incerti, S
    Ivanchenko, V
    Johnson, T
    Jones, F
    Koi, T
    Kokoulin, R
    Kossov, M
    Kurashige, H
    Lara, V
    Larsson, S
    Lei, F
    Link, O
    Longo, F
    Maire, M
    Mantero, A
    Mascialino, B
    McLaren, I
    Lorenzo, PM
    Minamimoto, K
    Murakami, K
    Nieminen, P
    Pandola, L
    Parlati, S
    Peralta, L
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (01) : 270 - 278
  • [3] Brankov JG, 2004, 2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, P1428
  • [4] Exploiting the x-ray refraction contrast with an analyser: the state of the art
    Bravin, A
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2003, 36 (10A) : A24 - A29
  • [5] Bushberg JT, 2011, The Essential Physics of Medical Imaging
  • [6] Diffraction enhanced x-ray imaging
    Chapman, D
    Thomlinson, W
    Johnston, RE
    Washburn, D
    Pisano, E
    Gmur, N
    Zhong, Z
    Menk, R
    Arfelli, F
    Sayers, D
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) : 2015 - 2025
  • [7] Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography
    Chen, Guang-Hong
    Zambelli, Joseph
    Li, Ke
    Bevins, Nicholas
    Qi, Zhihua
    [J]. MEDICAL PHYSICS, 2011, 38 (02) : 584 - 588
  • [8] An extended diffraction-enhanced imaging method for implementing multiple-image radiography
    Chou, Cheng-Ying
    Anastasio, Mark A.
    Brankov, Jovan G.
    Wernick, Miles N.
    Brey, Eric M.
    Connor, Dean M., Jr.
    Zhong, Zhong
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (07) : 1923 - 1945
  • [9] Analytical and experimental determination of signal-to-noise ratio and figure of merit in three phase-contrast imaging techniques
    Diemoz, P. C.
    Bravin, A.
    Langer, M.
    Coan, P.
    [J]. OPTICS EXPRESS, 2012, 20 (25): : 27670 - 27690
  • [10] Absorption, refraction and scattering in analyzer-based imaging: comparison of different algorithms
    Diemoz, Paul Claude
    Coan, Paola
    Glaser, Christian
    Bravin, Alberto
    [J]. OPTICS EXPRESS, 2010, 18 (04): : 3494 - 3509