Characterization of tumor imaging with microbubble-based ultrasound contrast agent, Sonazoid, in rabbit liver

被引:54
|
作者
Watanabe, R [1 ]
Matsumura, M [1 ]
Chen, CJ [1 ]
Kaneda, Y [1 ]
Fujimaki, M [1 ]
机构
[1] Daiichi Pharmaceut Co Ltd, New Prod Res Labs 2, Edogawa Ku, Tokyo 1348630, Japan
关键词
ultrasound contrast agent; Sonazoid; liver; VX-2; rabbit;
D O I
10.1248/bpb.28.972
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
In order to investigate improvement of hepatic tumor detectability by Sonazoid with phase inversion imaging, the contrast effects on the liver of metastatic carcinoma-model rabbits were evaluated by videodensitometry and visual assessment. Correlation between the contrast enhancement of Sonazoid and histopathology was examined using the same animals. Electron microscopy was performed on hepatic tissue from another healthy rabbits to identify the distribution of Sonazoid microbubbles. As a result, all tumors were smaller than 12 mm in diameter, and after intravenous injection of Sonazoid, they were surrounded with a ring of enhanced signal during the early phase (up to 30 s), followed by a clear contrast defect during the delayed phase (after 10 min). Histopathologic observation revealed that the ring-enhancement was caused by neovasculature in the tumor, and the contrast defects corresponded to living and dead parts of tumors, which lack Kupffer cells. Videodensitometric differences between tumor and healthy tissue markedly increased at delayed phase, and visual detectability of tumors was improved when Sonazoid was used. Ultrastructural analysis showed microbubble-like structures in Kupffer cells, which indicated that Sonazoid microbubbles were taken up with these cells. In conclusion, Sonazoid, used with phase inversion imaging, greatly increases the detectability of small hepatic tumors by highlighting neovascularity at early phase and providing clear contrast defects due to absence of Kupffer cells, which take up Sonazoid microbubbles, at delayed phase.
引用
收藏
页码:972 / 977
页数:6
相关论文
共 50 条
  • [21] Parametric imaging using contrast-enhanced ultrasound with Sonazoid for hepatocellular carcinoma
    Watanabe, Manabu
    Shiozawa, Kazue
    Takahashi, Masayoshi
    Wakui, Noritaka
    Otsuka, Yuichiro
    Kaneko, Hironori
    Tanikawa, Kayoko
    Shibuya, Kazutoshi
    Kamiyama, Naohisa
    Sumino, Yasukiyo
    JOURNAL OF MEDICAL ULTRASONICS, 2010, 37 (02) : 81 - 86
  • [22] Promoting the effect of microbubble-enhanced ultrasound on hyperthermia in rabbit liver
    Yang, Yuwen
    Luo, Huanqian
    Zhao, Yang
    Li, Lu
    He, Yan
    Xi, Fen
    Jin, Hai
    Gao, Ruru
    Luo, Qiong
    Liu, Jianhua
    JOURNAL OF MEDICAL ULTRASONICS, 2022, 49 (02) : 133 - 142
  • [23] Promoting the effect of microbubble-enhanced ultrasound on hyperthermia in rabbit liver
    Yuwen Yang
    Huanqian Luo
    Yang Zhao
    Lu Li
    Yan He
    Fen Xi
    Hai Jin
    Ruru Gao
    Qiong Luo
    Jianhua Liu
    Journal of Medical Ultrasonics, 2022, 49 : 133 - 142
  • [24] EFFECT OF MICROBUBBLE-ENHANCED ULTRASOUND ON RADIOFREQUENCY ABLATION OF RABBIT LIVER
    Chen, Zhong
    Zhao, Hongzhi
    Qiao, Xueyan
    Yi, Cuo
    Gao, Shunji
    Gao, Wenhong
    Liu, Zheng
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (07) : 1451 - 1459
  • [25] Enhancing effects of SonoVue, a microbubble sonographic contrast agent, on high-intensity focused ultrasound ablation in rabbit livers in vivo
    Luo, Wen
    Zhou, Xiaodong
    Ren, Xiaolong
    Zheng, Minjuan
    Zhang, Jun
    He, Guangbin
    JOURNAL OF ULTRASOUND IN MEDICINE, 2007, 26 (04) : 469 - 476
  • [26] Influence of Microbubble Shell Chemistry on the Destruction Threshold of Ultrasound Contrast Agent Microbubbles
    Mleczko, Michal
    Dicker, Stephen M.
    Wrenn, Steven P.
    Schmitz, Georg
    ACOUSTICAL IMAGING, VOL 31, 2012, 31 : 91 - 101
  • [27] Generation of a droplet inside a microbubble with the aid of an ultrasound contrast agent: First result
    Postema, Michiel
    ten Cate, Folkert J.
    Schmitz, Georg
    de Jong, Nico
    van Wamel, Annemieke
    LETTERS IN DRUG DESIGN & DISCOVERY, 2007, 4 (01) : 74 - 77
  • [28] Effects of Phospholipid Shell on the Generation of Second Harmonic of Ultrasound Contrast Agent Microbubble
    Chen, Ming-Huang
    Tsao, Jenho
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (07) : 1504 - 1508
  • [29] Contrast ultrasound imaging in liver disease
    Tranquart, F
    Bleuzen, A
    Correas, JM
    Kissel, A
    Tchuenbou, J
    Vandooren, E
    JOURNAL DE RADIOLOGIE, 2003, 84 (12): : 2025 - 2040
  • [30] Using microbubble contrast agent of different dosage to enhancing liver ablation induced by high-intensity focused ultrasound
    Li, Faqi
    Fu, Liyuan
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 6, 2009, 25 : 39 - +