Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access

被引:29
作者
Hernandez, DJ [1 ]
Sinkov, VA [1 ]
Roberts, WW [1 ]
Allaf, ME [1 ]
Patriciu, A [1 ]
Jarrett, TW [1 ]
Kavoussi, LR [1 ]
Stoianovici, D [1 ]
机构
[1] Johns Hopkins Med Inst, James Buchanan Brady Urol Inst, Baltimore, MD 21205 USA
关键词
kidney; swine; electric impedance; surgical instruments;
D O I
10.1016/S0022-5347(05)65823-5
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The traditional method of percutaneous renal access requires freehand needle placement guided by C-arm fluoroscopy, ultrasonography, or computerized tomography. This approach provides limited objective means for verifying successful access. We developed an impedance based percutaneous Smart Needle system and successfully used it to confirm collecting system access in ex vivo porcine kidneys. Materials and Methods: The Smart Needle consists of a modified 18 gauge percutaneous access needle with the inner stylet electrically insulated from the outer sheath. Impedance is measured between the exposed stylet tip and sheath using Model 4275 LCR meter (Hewlett-Packard, Sunnyvale, California). An ex vivo porcine kidney was distended by continuous gravity infusion of 100 cm. water saline from a catheter passed through the parenchyma into the collecting system. The Smart Needle was gradually inserted into the kidney to measure depth precisely using a robotic needle placement system, while impedance was measured continuously. Results: The Smart Needle was inserted 4 times in each of 4 kidneys. When the needle penetrated the distended collecting system in 11 of 16 attempts, a characteristic sharp drop in resistivity was noted from 1.9 to 1.1 ohm in. Entry into the collecting system was confirmed by removing the stylet and observing fluid flow from the sheath. This characteristic impedance change was observed only at successful entry into the collecting system. Conclusions: A characteristic sharp drop in impedance signifies successful entry into the collecting system. The Smart Needle system may prove useful for percutaneous kidney access.
引用
收藏
页码:1520 / 1523
页数:4
相关论文
共 10 条
[1]  
Bishoff Jay T., 1998, Journal of Endourology, V12, pS82
[2]   An electrical impedance index to distinguish between normal and cancerous tissues [J].
Blad, B ;
Wendel, P ;
Jönsson, M ;
Lindström, K .
JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1999, 23 (02) :57-62
[3]   VALUE OF SERIAL STEREOTACTIC BIOPSIES AND IMPEDANCE MONITORING IN THE TREATMENT OF DEEP BRAIN-TUMORS [J].
BROGGI, G ;
FRANZINI, A .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1981, 44 (05) :397-401
[4]   IMPEDANCE MEASURING DEVICE FOR DETECTION OF PENETRATION OF SPINAL CORD IN ANTERIOR PERCUTANEOUS CERVICAL CORDOTOMY - TECHNICAL NOTE [J].
GILDENBERG, PL ;
ZANES, C ;
FLITTER, M ;
LIN, PM ;
LAUTSCH, EV ;
TRUEX, RC .
JOURNAL OF NEUROSURGERY, 1969, 30 (01) :87-+
[5]  
Lee BR, 1999, PROSTATE, V39, P213, DOI 10.1002/(SICI)1097-0045(19990515)39:3<213::AID-PROS10>3.0.CO
[6]  
2-8
[7]   TISSUE CHARACTERIZATION BY IMPEDANCE - A MULTIFREQUENCY APPROACH [J].
RIGAUD, B ;
HAMZAOUI, L ;
CHAUVEAU, N ;
GRANIE, M ;
DIRINALDI, JPS ;
MORUCCI, JP .
PHYSIOLOGICAL MEASUREMENT, 1994, 15 :A13-A20
[8]   RF-FIELD INTERACTIONS WITH BIOLOGICAL-SYSTEMS - ELECTRICAL-PROPERTIES AND BIOPHYSICAL MECHANISMS [J].
SCHWAN, HP ;
FOSTER, KR .
PROCEEDINGS OF THE IEEE, 1980, 68 (01) :104-113
[9]  
Schwan HP., 1963, PHYS TECHNIQUES BIOL, P323, DOI DOI 10.1002/JCP.1030660505
[10]  
Stoianovici D, 1998, LECT NOTES COMPUT SC, V1496, P404, DOI 10.1007/BFb0056225