Pre-operative templating in THA using a short stem system: precision and accuracy of 2D versus 3D planning method

被引:19
|
作者
Reinbacher, Patrick [1 ]
Smolle, Maria Anna [1 ]
Friesenbichler, Joerg [1 ]
Draschl, Alexander [1 ]
Leithner, Andreas [1 ]
Maurer-Ertl, Werner [1 ]
机构
[1] Med Univ Graz, Dept Orthopaed & Trauma, Auenbruggerpl 5, A-8036 Graz, Austria
关键词
Total hip arthroplasty; Templating; Short stem; 2D; 3D; TOTAL HIP-ARTHROPLASTY; COMPUTED-TOMOGRAPHY; KNEE REPLACEMENT; REVISION; RISK; MORTALITY; SOFTWARE; OBESITY;
D O I
10.1186/s10195-022-00634-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Total hip arthroplasty (THA) is the most successful orthopaedic surgery of the past century. The current study aimed to compare the accuracy of digital planning using 2D versus 3D templating. Materials and methods Ninety-five THAs in 90 patients were included in the current study. Pre- and post-operative X-rays (in two planes) and low-dose rotation computed tomography scans from hip to foot were performed. Paired t-test and regression analyses were conducted to compare 2D and 3D templating accuracy of the definitive implant. Results Cup size planned both with 2D (p < 0.0001) and 3D (p = 0.012) templating was significantly different from the definitively used cup size. The difference between the 2D-planned and implanted stem size (p < 0.0001) was statistically significant. In contrast, there were no significant differences in the 3D-planned and implanted stem size (p = 0.181). Three-dimensional templating showed significantly higher accuracy than 2D templating in terms of cup size (1.1 +/- 1.4 versus 1.7 +/- 1.8; p = 0.007) and stem size (0.3 +/- 0.6 versus 0.7 +/- 0.7; p < 0.0001). With increasing body mass index (BMI), 2D templating of the stem became more inaccurate (p = 0.041). Remarkably, 3D templating remained accurate for all components (stem, p = 0.533; cup, p = 0.479) despite increasing BMI. Conclusion Despite extended planning time and increased exposure to radiation, 3D-based planning showed higher accuracy than 2D templating, especially in obese patients. On the basis of our results, we believe that 3D-based pre-operative planning in THA is justifiable and beneficial in patients with increased BMI.
引用
收藏
页数:7
相关论文
共 21 条
  • [1] Pre-operative templating in THA using a short stem system: precision and accuracy of 2D versus 3D planning method
    Patrick Reinbacher
    Maria Anna Smolle
    Joerg Friesenbichler
    Alexander Draschl
    Andreas Leithner
    Werner Maurer-Ertl
    Journal of Orthopaedics and Traumatology, 2022, 23
  • [2] Pre-operative planning and templating with 3-D printed models for complex primary and revision total hip arthroplasty
    Maryada, Venkateshwar Reddy
    Mulpur, Praharsha
    Eachempati, Krishna Kiran
    Annapareddy, Adarsh
    Prasad, Vemaganti Badri Narayana
    Reddy, A. V. Gurava
    JOURNAL OF ORTHOPAEDICS, 2022, 34 : 240 - 245
  • [3] Comparison of the Accuracy of 2D and 3D Templating for Revision Total Hip Replacement
    Winter, Philipp
    Fritsch, Ekkehard
    Konig, Jochem
    Wolf, Milan
    Landgraeber, Stefan
    Orth, Patrick
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (03):
  • [4] Comparison of the accuracy of 2D and 3D templating methods for planning primary total hip replacement: a systematic review and meta-analysis
    Bishi, Habeeb
    Smith, Joshua B., V
    Asopa, Vipin
    Field, Richard E.
    Sochart, David H.
    Wang, Chao
    EFORT OPEN REVIEWS, 2022, 7 (01) : 70 - 83
  • [5] Do the sizes of total hip arthroplasty implants match between 3D planning software and 2D templating?
    Pansard, Erwan
    Vigan, Marie
    Bauer, Thomas
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2024, 110 (02)
  • [6] Pre-operative arthritic glenoid assessment: 3D automated planning software versus manual multiplanar measurements of version and inclination
    Hall, Tim
    Wong, Joshua Rui Yen
    Dirckx, Margo
    Rajesparan, Kannan
    Rashid, Abbas
    JOURNAL OF ORTHOPAEDICS, 2023, 36 : 24 - 28
  • [7] Validation of a statistical shape model-based 2D/3D reconstruction method for determination of cup orientation after THA
    G. Zheng
    J. von Recum
    L.-P. Nolte
    P. A. Grützner
    S. D. Steppacher
    J. Franke
    International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 225 - 231
  • [8] Validation of a statistical shape model-based 2D/3D reconstruction method for determination of cup orientation after THA
    Zheng, G.
    von Recum, J.
    Nolte, L. -P.
    Gruetzner, P. A.
    Steppacher, S. D.
    Franke, J.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (02) : 225 - 231
  • [9] Solving 3D Inverse Problems using Pre-trained 2D Diffusion Models
    Chung, Hyungjin
    Ryu, Dohoon
    Mccann, Michael T.
    Klasky, Marc L.
    Ye, Jong Chul
    2023 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2023, : 22542 - 22551
  • [10] Maintenance of Integrity of Upper Facet Joints during Simulated Percutaneous Pedicle Screw Insertion Using 2D versus 3D Planning
    Archavlis, Eleftherios
    Ringel, Florian
    Kantelhardt, Sven
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2019, 80 (04) : 269 - 276