Use of Continuous Glucose Monitoring in the Assessment and Management of Patients With Diabetes and Chronic Kidney Disease

被引:33
|
作者
Ling, James
Ng, Jack K. C.
Chan, Juliana C. N.
Chow, Elaine
机构
[1] Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Prince of Wales Hospital
[2] Hong Kong Institute of Diabetes and Obesity, The Chinese University of Hong Kong
[3] Phase 1 Clinical Trial Centre, The Chinese University of Hong Kong, Prince of Wales Hospital
来源
关键词
continuous glucose monitoring; end stage kidney disease (ESKD); dialysis; diabetes; type 2 (non-insulin-dependent) diabetes mellitus; diabetic kidney disease; diabetic nephropathy; STAGE RENAL-DISEASE; GLYCEMIC CONTROL; BLOOD-GLUCOSE; SERUM-ALBUMIN; HEMODIALYSIS-PATIENTS; PERITONEAL-DIALYSIS; AVERAGE GLUCOSE; INSULIN; HYPOGLYCEMIA; FRUCTOSAMINE;
D O I
10.3389/fendo.2022.869899
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In developed countries, diabetes is the leading cause of chronic kidney disease (CKD) and accounts for 50% of incidence of end stage kidney disease. Despite declining prevalence of micro- and macrovascular complications, there are rising trends in renal replacement therapy in diabetes. Optimal glycemic control may reduce risk of progression of CKD and related death. However, assessing glycemic control in patients with advanced CKD and on dialysis (G4-5) can be challenging. Laboratory biomarkers, such as glycated haemoglobin (HbA(1c)), may be biased by abnormalities in blood haemoglobin, use of iron therapy and erythropoiesis-stimulating agents and chronic inflammation due to uraemia. Similarly, glycated albumin and fructosamine may be biased by abnormal protein turnover. Patients with advanced CKD exhibited heterogeneity in glycemic control ranging from severe insulin resistance to 'burnt-out' beta-cell function. They also had high risk of hypoglycaemia due to reduced renal gluconeogenesis, frequent use of insulin and dysregulation of counterregulatory hormones. Continuous glucose monitoring (CGM) systems measure glucose in interstitial fluid every few minutes and provide an alternative and more reliable method of glycemic assessment, including asymptomatic hypoglycaemia and hyperglycaemic excursions. Recent international guidelines recommended use of CGM-derived Glucose Management Index (GMI) in patients with advanced CKD although data are scarce in this population. Using CGM, patients with CKD were found to experience marked glycemic fluctuations with hypoglycemia due to loss of glucose and insulin during haemodialysis (HD) followed by hyperglycemia in the post-HD period. On the other hand, during peritoneal dialysis, patients may experience glycemic excursions with influx of glucose from dialysate solutions. These undesirable glucose exposure and variability may accelerate decline of residual renal function. Although CGM may improve the quality of glycemic monitoring and control in populations with CKD, further studies are needed to confirm the accuracy, optimal mode and frequency of CGM as well as their cost-effectiveness and user-acceptability in patients with advanced CKD and dialysis.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Efficacy of linagliptin and teneligliptin for glycemic control in type 2 diabetic patients with chronic kidney disease: assessment by continuous glucose monitoring; a pilot study
    Tanaka K.
    Okada Y.
    Mori H.
    Inada Y.
    Suzuka K.
    Uriu K.
    Tanaka Y.
    Diabetology International, 2016, 7 (4) : 368 - 374
  • [32] Continuous Glucose Monitoring: Review of an Innovation in Diabetes Management
    Mian, Zainab
    Hermayer, Kathie L.
    Jenkins, Alicia
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2019, 358 (05): : 332 - 339
  • [33] Continuous Glucose Monitoring for Diabetes Management During Pregnancy
    Battarbee, Ashley N.
    Durnwald, Celeste
    Yee, Lynn M.
    Valent, Amy M.
    OBSTETRICS AND GYNECOLOGY, 2024, 144 (05): : 649 - 659
  • [34] CHANGES IN HOSPITALIZATIONS FOR SEVERE HYPOGLYCEMIA AND HYPERGLYCEMIA AND CONTINUOUS GLUCOSE MONITOR (CGM) USE IN TYPE 2 DIABETES AND CHRONIC KIDNEY DISEASE (CKD) PATIENTS
    Hannah, K.
    Nemlekar, P.
    Johnson, M.
    Chernavvsky, D.
    Norman, G.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2023, 25 : A61 - A61
  • [35] Progress and indication for use of continuous glucose monitoring in patients with diabetes in pregnancy: a review
    Song, Yu
    Zhai, Xiaodan
    Bai, Yu
    Liu, Cong
    Zhang, Le
    FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [36] Assessment and management of vascular disease risk in patients with chronic kidney disease
    Brown, W. Virgil
    Bakris, George
    Lerma, Edgar
    Chertow, Glenn
    JOURNAL OF CLINICAL LIPIDOLOGY, 2011, 5 (04) : 251 - 260
  • [37] Diabetes Healthcare Professionals Use Multiple Continuous Glucose Monitoring Data Indicators to Assess Glucose Management
    Sheng, Tong
    Offringa, Reid
    Kerr, David
    Clements, Mark
    Fischer, Jerome
    Parks, Linda
    Greenfield, Michael
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2020, 14 (02): : 271 - 276
  • [38] Assessing the prevalence, monitoring and management of chronic kidney disease in patients with diabetes compared with those without diabetes in general practice
    New, J. P.
    Middleton, R. J.
    Klebe, B.
    Farmer, C. K. T.
    de Lusignan, S.
    Stevens, P. E.
    O'Donoghue, D. J.
    DIABETIC MEDICINE, 2007, 24 (04) : 364 - 369
  • [39] Clinical assessment and management of dyslipidemia in patients with chronic kidney disease
    Nitta, Kosaku
    CLINICAL AND EXPERIMENTAL NEPHROLOGY, 2012, 16 (04) : 522 - 529
  • [40] Clinical assessment and management of dyslipidemia in patients with chronic kidney disease
    Kosaku Nitta
    Clinical and Experimental Nephrology, 2012, 16 : 522 - 529