Head motion measurement and correction using FID navigators

被引:50
|
作者
Wallace, Tess E. [1 ]
Afacan, Onur [1 ]
Waszak, Maryna [2 ,3 ,4 ]
Kober, Tobias [2 ,3 ,4 ]
Warfield, Simon K. [1 ]
机构
[1] Harvard Med Sch, Boston Childrens Hosp, Dept Radiol, Computat Radiol Lab, Boston, MA USA
[2] Siemens Healthcare AG, Adv Clin Imaging Technol, Lausanne, Switzerland
[3] Univ Hosp CHUV, Dept Radiol, Lausanne, Switzerland
[4] Ecole Polytech Fed Lausanne, LTS5, Lausanne, Switzerland
关键词
coil sensitivity profile; FID navigators; motion correction; MRI motion measurement; HUMAN BRAIN; RETROSPECTIVE CORRECTION; IMAGE QUALITY; MRI; COIL; REDUCTION; ACCURACY; ARTIFACTS; SENSE;
D O I
10.1002/mrm.27381
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a novel framework for rapid, intrinsic head motion measurement in MRI using FID navigators (FIDnavs) from a multichannel head coil array. Methods: FIDnavs encode substantial rigid-body motion information; however, current implementations require patient-specific training with external tracking data to extract quantitative positional changes. In this work, a forward model of FIDnav signals was calibrated using simulated movement of a reference image within a model of the spatial coil sensitivities. A FIDnav module was inserted into a nonselective 3D FLASH sequence, and rigid-body motion parameters were retrospectively estimated every readout time using nonlinear optimization to solve the inverse problem posed by the measured FIDnavs. This approach was tested in simulated data and in 7 volunteers, scanned at 3T with a 32-channel head coil array, performing a series of directed motion paradigms. Results: FIDnav motion estimates achieved mean absolute errors of 0.34 +/- 0.49 mm and 0.52 +/- 0.61 degrees across all subjects and scans, relative to ground-truth motion measurements provided by an electromagnetic tracking system. Retrospective correction with FIDnav motion estimates resulted in substantial improvements in quantitative image quality metrics across all scans with intentional head motion. Conclusions: Quantitative rigid-body motion information can be effectively estimated using the proposed FIDnav-based approach, which represents a practical method for retrospective motion compensation in less cooperative patient populations.
引用
收藏
页码:258 / 274
页数:17
相关论文
共 50 条
  • [1] Head Motion Detection Using FID Navigators
    Kober, Tobias
    Marques, Jose P.
    Gruetter, Rolf
    Krueger, Gunnar
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (01) : 135 - 143
  • [2] Prospective motion correction in kidney MRI using FID navigators
    Ariyurek, Cemre
    Wallace, Tess E.
    Kober, Tobias
    Kurugol, Sila
    Afacan, Onur
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (01) : 276 - 285
  • [3] Prospective head motion correction using FID-guided on-demand image navigators
    Waszak, Maryna
    Falkovskiy, Pavel
    Hilbert, Tom
    Bonnier, Guillaume
    Marechal, Benedicte
    Meuli, Reto
    Gruetter, Rolf
    Kober, Tobias
    Krueger, Gunnar
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (01) : 193 - 203
  • [4] Motion compensated carotid MRI using FID navigators
    Petter Dyverfeldt
    Vibhas S Deshpande
    Tobias Kober
    Gunnar Krueger
    David Saloner
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [5] Dynamic distortion correction for functional MRI using FID navigators
    Wallace, Tess E.
    Polimeni, Jonathan R.
    Stockmann, Jason P.
    Hoge, W. Scott
    Kober, Tobias
    Warfield, Simon K.
    Afacan, Onur
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (03) : 1294 - 1307
  • [6] Rapid motion estimation and correction using self-encoded FID navigators in 3D radial MRI
    Wallace, Tess E.
    Piccini, Davide
    Kober, Tobias
    Warfield, Simon K.
    Afacan, Onur
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (03) : 1057 - 1066
  • [7] Real-time motion correction using octant navigators
    van der Kouwe, A
    Dale, A
    NEUROIMAGE, 2001, 13 (06) : S48 - S48
  • [8] Prospective motion correction for brain MRI using spherical navigators
    Hewlett, Miriam
    Oran, Omer
    Liu, Junmin
    Drangova, Maria
    MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (04) : 1528 - 1540
  • [9] Rapid measurement and correction of spatiotemporal B0 field changes using FID navigators and a multi-channel reference image
    Wallace, Tess E.
    Afacan, Onur
    Kober, Tobias
    Wartield, Simon K.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (02) : 575 - 589
  • [10] Prospective head motion correction at 3 Tesla with wireless NMR markers and ultrashort echo navigators
    Sengupta, Saikat
    Glenn, Antonio
    Rogers, Baxter P.
    MAGNETIC RESONANCE IMAGING, 2024, 114