Compact optical instrument for simultaneous determination of oxygen and carbon dioxide

被引:18
|
作者
Perez de Vargas-Sansalvador, Isabel M. [1 ]
Martinez-Olmos, Antonio [2 ]
Palma, Alberto J. [2 ]
Dolores Fernandez-Ramos, Maria [1 ]
Fermin Capitan-Vallvey, Luis [1 ]
机构
[1] Univ Granada, ECsens, Dept Analyt Chem, Fac Sci, E-18071 Granada, Spain
[2] Univ Granada, ECsens, Dept Elect & Comp Technol, Fac Sci, E-18071 Granada, Spain
关键词
Carbon dioxide; Oxygen; Optical gas sensor; Phosphorescence; Portable instrumentation; CHEMICAL SENSORS; PORTABLE INSTRUMENTATION; FLUORESCENCE; CO2; PH; PORPHYRIN; FIBER;
D O I
10.1007/s00604-010-0520-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multi-analyte platform based on a portable instrument is presented that enables oxygen and carbon dioxide to be determined in sample gases. The use of four sensing channels (two channels for each analyte to provide redundancy) warrants high system reliability. The sensing scheme in case of oxygen is based on the quenching of the phosphorescence of the platinum octaethylporphyrin complex. In case of carbon dioxide, a secondary inner-filter effect is exploited that is caused by a pH indicator whose color is reversibly changed. The sensing membranes were placed directly on the detectors and on the light sources so to make additional optical element dispensable, reduce system costs, avoid problems related to optical alignment, optimize the efficiency of data acquisition, and enable facile replacement of sensors. The resulting microcontroller-based system is immune against optical and electrical interferences, contains simple digital signal processing circuitry, and has low power consumption. The response of the system to the two gases was modeled, and calibration curves are corrected for effects of temperature. The instrument was characterized in terms of cross-sensitivity and dynamic response. It can determine oxygen and carbon dioxide in terms of volume percentage.
引用
收藏
页码:455 / 464
页数:10
相关论文
共 50 条
  • [31] Variability of Vascular Reactivity in the Retina and Choriocapillaris to Oxygen and Carbon Dioxide Using Optical Coherence Tomography Angiography
    Ashimatey, Bright S.
    Zhou, Xiao
    Chu, Zhongdi
    Alluwimi, Muhammed
    Wang, Ruikang K.
    Kashani, Amir H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (02)
  • [32] SIMULTANEOUS DETERMINATION OF HEMOGLOBIN AND MYOGLOBIN OXYGEN BINDING CURVES BY SPECTRAL CURVE FITTING
    BARLOW, CH
    KELLY, KA
    KELLY, JJ
    APPLIED SPECTROSCOPY, 1992, 46 (05) : 758 - 763
  • [33] Brain tissue oxygen pressure, carbon dioxide pressure and pH during ischemia
    Hoffman, WE
    Charbel, FT
    Edelman, G
    Hannigan, K
    Ausman, JI
    NEUROLOGICAL RESEARCH, 1996, 18 (01) : 54 - 56
  • [34] Continuous, automated and simultaneous measurement of oxygen uptake and carbon dioxide evolution in biological systems
    Govind, R
    Gao, C
    Lai, L
    Tabak, HH
    WATER ENVIRONMENT RESEARCH, 1997, 69 (01) : 73 - 80
  • [35] Optical clumped isotope thermometry of carbon dioxide
    Prokhorov, Ivan
    Kluge, Tobias
    Janssen, Christof
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [36] Effects of oxygen and carbon dioxide on mean cell volume
    Kojima, N
    Tatsumi, N
    Kojima, K
    Kirihigashi, K
    ACTA HAEMATOLOGICA, 1998, 99 (02) : 65 - 68
  • [37] The interaction between oxygen and carbon dioxide movements in fishes
    Brauner, CJ
    Randall, DJ
    COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-PHYSIOLOGY, 1996, 113 (01): : 83 - 90
  • [38] Compact optical probe for flame temperature and carbon dioxide using interband cascade laser absorption near 4.2 μm
    Girard, J. J.
    Spearrin, R. M.
    Goldenstein, C. S.
    Hanson, R. K.
    COMBUSTION AND FLAME, 2017, 178 : 158 - 167
  • [39] Recent Technologies for Transcutaneous Oxygen and Carbon Dioxide Monitoring
    Bernasconi, Sara
    Angelucci, Alessandra
    De Cesari, Anastasia
    Masotti, Aurora
    Pandocchi, Maurizio
    Vacca, Francesca
    Zhao, Xin
    Paganelli, Chiara
    Aliverti, Andrea
    DIAGNOSTICS, 2024, 14 (08)
  • [40] The Sodium-Oxygen/Carbon Dioxide Electrochemical Cell
    Xu, Shaomao
    Wei, Shuya
    Wang, Hongsen
    Abruna, Hector D.
    Archer, Lynden A.
    CHEMSUSCHEM, 2016, 9 (13) : 1600 - 1606