Intra-and inter-reader reliability of semi-automated quantitative morphometry measurements and vertebral fracture assessment using lateral scout views from computed tomography

被引:37
作者
Kim, Y. M. [1 ,2 ,3 ]
Demissie, S. [4 ]
Eisenberg, R. [1 ,2 ]
Samelson, E. J. [5 ,6 ,7 ]
Kiel, D. P. [5 ,6 ,7 ]
Bouxsein, M. L. [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Ctr Adv Orthopaed Studies, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Dept Orthopaed Surg, Boston, MA USA
[3] NHIC Ilsan Hosp, Dept Internal Med, Goyang Shi, Gyounggi Do, South Korea
[4] Boston Univ, Sch Publ Hlth, Dept Biostat, Boston, MA USA
[5] Hebrew SeniorLife, Inst Aging Res, Boston, MA USA
[6] Harvard Univ, Sch Med, Dept Med, Boston, MA USA
[7] Beth Israel Deaconess Med Ctr, Div Gerontol, Boston, MA 02215 USA
关键词
Computed tomography; Reliability; Semi-automated vertebral morphometry; Vertebral fracture; X-RAY ABSORPTIOMETRY; OSTEOPOROTIC FRACTURES; APPEARANCE MODELS; PREVALENT; RISK; RECOGNITION; PRECISION; IMAGES; IDENTIFICATION; RADIOGRAPHY;
D O I
10.1007/s00198-011-1530-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intra-and inter-reader reliability of semi-automated quantitative vertebral morphometry measurements was determined using lateral computed tomography (CT) scout views. The method requires less time than conventional morphometry. Reliability was excellent for vertebral height measurements, good for height ratios, and comparable to semi-quantitative grading by radiologists for identification of vertebral fractures. Introduction Underdiagnosis and undertreatment of vertebral fracture (VFx) is a well-known problem worldwide. Thus, new methods are needed to facilitate identification of VFx. This study aimed to determine intra- and inter-reader reliability of semi-automated quantitative vertebral morphometry based on shape-based statistical modeling (SpineAnalyzer, Optasia Medical, Cheadle, UK). Methods Two non-radiologists independently assessed vertebral morphometry from CT lateral scout views at two time points in 96 subjects (50 men, 46 women, 70.3 +/- 8.9 years) selected from the Framingham Heart Study Offspring and Third Generation Multi-Detector CT Study. VFxs were classified based solely on morphometry measurements using Genant's criteria. Intraclass correlation coefficients (ICCs), root mean squared coefficient of variation (RMS CV) and kappa (k) statistics were used to assess reliability. Results We analyzed 1,246 vertebrae in 96 subjects. The analysis time averaged 5.4 +/- 1.7 min per subject (range, 3.2-9.1 min). Intra-and inter-reader ICCs for vertebral heights were excellent (> 0.95) for all vertebral levels combined. Intra-and inter-reader RMS CV for height measurements ranged from 2.5% to 3.9% and 3.3% to 4.4%, respectively. Reliability of vertebral height ratios was good to fair. Based on morphometry measurements alone, readers A and B identified 51-52 and 46-59 subjects with at least one prevalent VFx, respectively, and there was a good intra-and inter-reader agreement (k = 0.59-0.69) for VFx identification. Conclusions Semi-automated quantitative vertebral morphometry measurements from CT lateral scout views are convenient and reproducible, and may facilitate assessment of VFx.
引用
收藏
页码:2677 / 2688
页数:12
相关论文
共 38 条
  • [1] BLACK DM, 1995, J BONE MINER RES, V10, P890
  • [2] Brett Alan, 2009, Spine (Phila Pa 1976), V34, P2437, DOI 10.1097/BRS.0b013e3181b2eb69
  • [3] A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES
    COHEN, J
    [J]. EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) : 37 - 46
  • [4] Active appearance models
    Cootes, TF
    Edwards, GJ
    Taylor, CJ
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2001, 23 (06) : 681 - 685
  • [5] Underdiagnosis of vertebral fractures is a worldwide problem: The IMPACT study
    Delmas, PD
    van de Langerijt, L
    Watts, NB
    Eastell, R
    Genant, H
    Grauer, A
    Cahall, DL
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2005, 20 (04) : 557 - 563
  • [6] Vertebral deformity, back symptoms, and functional limitations among older women: The Framingham Study
    Edmond, SL
    Kiel, DP
    Samelson, EJ
    Kelly-Hayes, M
    Felson, DT
    [J]. OSTEOPOROSIS INTERNATIONAL, 2005, 16 (09) : 1086 - 1095
  • [7] Short-term precision for morphometric X-ray absorptiometry
    Ferrar, L
    Jiang, G
    Eastell, R
    [J]. OSTEOPOROSIS INTERNATIONAL, 2001, 12 (09) : 710 - 715
  • [8] Algorithm-based qualitative and semiquantitative identification of prevalent vertebral fracture: Agreement between different readers, imaging modalities, and diagnostic approaches
    Ferrar, Lynne
    Jiang, Guirong
    Schousboe, John T.
    DeBold, Charles R.
    Eastell, Richard
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2008, 23 (03) : 417 - 424
  • [9] Fleiss JL., 1981, The measurement of interrater agreement. In, V2nd, P211
  • [10] Osteoporosis and vertebral compression fractures-continued missed opportunities
    Freedman, Brett A.
    Potter, Benjamin K.
    Nesti, Leon J.
    Giuliani, Jeffrey R.
    Hampton, Chadwick
    Kuklo, Timothy R.
    [J]. SPINE JOURNAL, 2008, 8 (05) : 756 - 762