Application of hollow fiber membrane contactor for the removal of carbon dioxide from water under liquid-liquid extraction mode

被引:21
作者
Agrahari, Gunjan K. [1 ]
Verma, Nishith [1 ]
Bhattacharya, Prashant K. [1 ]
机构
[1] Indian Inst Technol, Dept Chem Engn, Kanpur 208016, Uttar Pradesh, India
关键词
Degasification; Carbon dioxide; Hollow fiber membrane contactor; Permeation; Mathematical model; AMMONIA REMOVAL; CO2; REMOVAL; ULTRAPURE WATER; REUSE SYSTEMS; PARAMETERS; STREAMS;
D O I
10.1016/j.memsci.2011.03.060
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this study, we investigate the application of a hollow fiber membrane contactor operated in the LLE mode for the removal of dissolved CO(2) from water. The membrane contactor consists of hydrophobic polypropylene microporous hollow fibers. Experiments are performed to determine the extent of CO(2) removal from the feed water flowing through the lumens of the hollow fibers. The feed at different concentration levels of dissolved CO(2) was extracted using aqueous diethanolamine solution flowing on the shell side of the contactor. A mathematical model was developed, incorporating radial and axial diffusion of solute CO(2) in the lumen and its permeation through the pores of the membrane. The governing second order partial differential equation of species balance was numerically solved using the alternate direction implicit technique. The developed mathematical model was used to predict the concentration profiles of CO(2) and study its transport through water and membrane pores. The numerical value of the permeation coefficient obtained for CO(2) in the hollow fiber membrane was found to be in good agreement with the data in literature. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:323 / 333
页数:11
相关论文
共 37 条
[1]  
[Anonymous], MECH COMPOSITE MAT
[2]   Ammonia removal from aqueous solutions using hollow-fiber membrane contactors [J].
Ashrafizadeh, S. N. ;
Khorasani, Z. .
CHEMICAL ENGINEERING JOURNAL, 2010, 162 (01) :242-249
[3]   Hollow fiber membrane degassing in ultrapure water and microbiocontamination [J].
Bhaumik, D ;
Majumdar, S ;
Fan, QX ;
Sirkar, KK .
JOURNAL OF MEMBRANE SCIENCE, 2004, 235 (1-2) :31-41
[4]   Modeling CO2 degassing and pH in a stream-aquifer system [J].
Choi, J ;
Hulseapple, SM ;
Conklin, MH ;
Harvey, JW .
JOURNAL OF HYDROLOGY, 1998, 209 (1-4) :297-310
[5]   DECARBONATION AND DEAERATION OF WATER BY USE OF SELECTIVE HOLLOW FIBERS [J].
COLE, CA ;
GENETELLI, EJ .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1970, 4 (06) :514-+
[6]   Membrane contactors in the beverage industry for controlling the water gas composition [J].
Criscuoli, A ;
Drioli, E ;
Moretti, U .
ADVANCED MEMBRANE TECHNOLOGY, 2003, 984 :1-16
[7]   Membrane-solvent selection for CO2 removal using membrane gas-liquid contactors [J].
Dindore, VY ;
Brilman, DWF ;
Geuzebroek, FH ;
Versteeg, GF .
SEPARATION AND PURIFICATION TECHNOLOGY, 2004, 40 (02) :133-145
[8]   State of the art and recent progresses in membrane contactors [J].
Drioli, E ;
Curcio, E ;
Di Profio, G .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2005, 83 (A3) :223-233
[9]  
Drioli E., 2006, Membrane Contactors: Fundamentals, Applications and Potentialities
[10]   Application of vacuum membrane distillation for ammonia removal [J].
EL-Bourawi, M. S. ;
Khayet, M. ;
Ma, R. ;
Ding, Z. ;
Li, Z. ;
Zhang, X. .
JOURNAL OF MEMBRANE SCIENCE, 2007, 301 (1-2) :200-209