Development of an Aptamer Based Luminescent Optical Fiber Sensor for the Continuous Monitoring of Hg2+ in Aqueous Media

被引:20
作者
De Acha, Nerea [1 ]
Elosua, Cesar [1 ,2 ]
Arregui, Francisco J. [1 ,2 ]
机构
[1] Univ Publ Navarra, Dept Elect Elect & Commun Engn, Ed Tejos,Campus Arrosadia S-N, E-31006 Navarra, Spain
[2] Univ Publ Navarra, Inst Smart Cities, Ed Jeronimo Ayanz,Campus Arrosadia S-N, E-31006 Navarra, Spain
关键词
optical fiber biosensor; luminescent biosensor; fluorophore-labelled aptamer; mercury detection; MERCURY; FLUORESCENT; BIOSENSOR; WATER; IONS; TOXICITY; LEAD(II); AFFINITY;
D O I
10.3390/s20082372
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fluorescent optical fiber sensor for the detection of mercury (Hg2+) ions in aqueous solutions is presented in this work. The sensor was based on a fluorophore-labeled thymine (T)-rich oligodeoxyribonucleotide (ON) sequence that was directly immobilized onto the tip of a tapered optical fiber. In the presence of mercury ions, the formation of T-Hg2+-T mismatches quenches the fluorescence emission by the labeled fluorophore, which enables the measurement of Hg2+ ions in aqueous solutions. Thus, in contrast to commonly designed sensors, neither a fluorescence quencher nor a complementary ON sequence is required. The sensor presented a response time of 24.8 seconds toward 5 x 10(-12) M Hg2+. It also showed both good reversibility (higher than the 95.8%) and selectivity: the I-0/I variation was 10 times higher for Hg2+ ions than for Mn2+ ions. Other contaminants examined (Co2+, Ag+, Cd2+, Ni2+, Ca2+, Pb2+, Mn2+, Zn2+, Fe3+, and Cu2+) presented an even lower interference. The limit of detection of the sensor was 4.73 x 10(-13) M Hg2+ in buffer solution and 9.03 x 10(-13) M Hg2+ in ultrapure water, and was also able to detect 5 x 10(-12) M Hg2+ in tap water.
引用
收藏
页数:13
相关论文
共 48 条
[1]   A FIBER OPTIC BIOSENSOR - COMBINATION TAPERED FIBERS DESIGNED FOR IMPROVED SIGNAL ACQUISITION [J].
ANDERSON, GP ;
GOLDEN, JP ;
LIGLER, FS .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (05) :249-256
[2]  
[Anonymous], 2014, INTERDISCIP TOXICOL
[3]  
[Anonymous], 2011, Chron Young Sci, DOI [10.4103/2229-5186.79345, DOI 10.4103/2229-5186.79345]
[4]  
[Anonymous], EXPANDING VISION SEN
[5]   A review on various electrochemical techniques for heavy metal ions detection with different sensing platforms [J].
Bansod, BabanKumar ;
Kumar, Tejinder ;
Thakur, Ritula ;
Rana, Shakshi ;
Singh, Inderbir .
BIOSENSORS & BIOELECTRONICS, 2017, 94 :443-455
[6]   On the Mechanism of SDS-Induced Protein Denaturation [J].
Bhuyan, Abani K. .
BIOPOLYMERS, 2010, 93 (02) :186-199
[7]   Contribution by urban and agricultural pesticide uses to water contamination at the scale of the Marne watershed [J].
Blanchoud, H. ;
Moreau-Guigon, E. ;
Farrugia, F. ;
Chevreuil, M. ;
Mouchel, J. M. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2007, 375 (1-3) :168-179
[8]   Mercury Toxicity and Neurodegenerative Effects [J].
Carocci, Alessia ;
Rovito, Nicola ;
Sinicropi, Maria Stefania ;
Genchi, Giuseppe .
REVIEWS OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, VOL 229, 2014, 229 :1-18
[9]   Fluorescent and colorimetric sensors for environmental mercury detection [J].
Chen, Guiqiu ;
Guo, Zhi ;
Zeng, Guangming ;
Tang, Lin .
ANALYST, 2015, 140 (16) :5400-5443
[10]   Handheld, low-cost electronic device for rapid, real-time fluorescence-based detection of Hg2+, using aptamer-templated ZnO quantum dots [J].
Daniel, S. C. G. Kiruba ;
Kumar, Archiev ;
Sivasakthi, K. ;
Thakur, Chetan Singh .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 290 :73-78