Determination of Cd in urine by cloud point extraction-tungsten coil atomic absorption spectrometry

被引:36
作者
Donati, George L. [1 ]
Pharr, Kathryn E. [1 ]
Calloway, Clifton P., Jr. [2 ]
Nobrega, Joaquim A. [3 ]
Jones, Bradley T. [1 ]
机构
[1] Wake Forest Univ, Dept Chem, Winston Salem, NC 27109 USA
[2] Winthrop Univ, Dept Chem, Rock Hill, SC 29733 USA
[3] Univ Fed Sao Carlos, Dept Quim, BR-13560 Sao Carlos, SP, Brazil
基金
美国国家科学基金会;
关键词
tungsten coil; atomic absorption; cloud point extraction; cadmium; urine;
D O I
10.1016/j.talanta.2008.05.003
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cadmium concentrations in human urine are typically at or below the 1 mu g L-1 level, so only a handful of techniques may be appropriate for this application. These include sophisticated methods such as graphite furnace atomic absorption spectrometry and inductively coupled plasma mass spectrometry. While tungsten coil atomic absorption spectrometry is a simpler and less expensive technique, its practical detection limits often prohibit the detection of Cd in normal urine samples. In addition, the nature of the urine matrix often necessitates accurate background correction techniques, which would add expense and complexity to the tungsten coil instrument. This manuscript describes a cloud point extraction method that reduces matrix interference while preconcentrating Cd by a factor of 15. Ammonium pyrrolidinedithiocarbamate and Triton X-114 are used as complexing agent and surfactant, respectively, in the extraction procedure. Triton X-114 forms an extractantcoacervate surfactant-rich phase that is denser than water,so the aqueous Supernatant is easily removed leaving the metal-containing surfactant layer intact. A 25 mu L aliquot of this preconcentrated sample is placed directly onto the tungsten coil for analysis. The Cloud point extraction procedure allows for simple background correction based either on the measurement of absorption at a nearby wavelength, or measurement of absorption at a time in the atomization step immediately prior to the onset of the Cd signal. Seven human urine samples are analyzed by this technique and the results are compared to those found by the inductively Coupled plasma mass spectrometry analysis of the same samples performed at a different institution. The limit of detection for Cd in urine is 5 ng L-1 for cloud point extraction tungsten coil atomic absorption spectrometry. The accuracy of the method is determined with a standard reference material (toxic metals in freeze-dried urine) and the determined Values agree with the reported levels at the 95% confidence level. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1252 / 1255
页数:4
相关论文
共 19 条
[1]   Determination of cadmium with a portable, battery-powered tungsten coil atomic absorption spectrometer [J].
Batchelor, JD ;
Thomas, SE ;
Jones, BT .
APPLIED SPECTROSCOPY, 1998, 52 (08) :1086-1091
[2]  
BOGES DLG, 2003, J ANAL ATOM SPECTROM, V18, P501
[3]   Determination of cadmium and lead in mussels by tungsten coil electrothermal atomic absorption spectrometry [J].
Bruhn, CG ;
San Francisco, NA ;
Neira, JY ;
Nóbrega, JA .
TALANTA, 1999, 50 (05) :967-975
[4]   ANALYTICAL EVALUATION OF A TUNGSTEN COIL ATOMIZER FOR CADMIUM, LEAD, CHROMIUM, MANGANESE, NICKEL AND COBALT DETERMINATION BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
BRUHN, CG ;
AMBIADO, FE ;
CID, HJ ;
WOERNER, R ;
TAPIA, J ;
GARCIA, R .
ANALYTICA CHIMICA ACTA, 1995, 306 (2-3) :183-192
[5]  
Bruhn CG, 1996, QUIM ANAL, V15, P191
[6]   Urinary cadmium elimination as a biomarker of exposure for evaluating a cadmium dietary exposure-biokinetics model [J].
Choudhury, H ;
Harvey, T ;
Thayer, WC ;
Lockwood, TF ;
Stiteler, WM ;
Goodrum, PE ;
Hassett, JM ;
Diamond, GL .
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART A, 2001, 63 (05) :321-350
[7]   Determination of cadmium in coal using solid sampling graphite furnace high-resolution continuum source atomic absorption spectrometry [J].
da Silva, AF ;
Borges, DLG ;
Lepri, FG ;
Welz, B ;
Curtius, AJ ;
Heitmann, U .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (08) :1835-1841
[8]   Determination of cadmium in biological samples [J].
Davis, AC ;
Wu, P ;
Zhang, XF ;
Hou, XD ;
Jones, BT .
APPLIED SPECTROSCOPY REVIEWS, 2006, 41 (01) :35-75
[9]   Acid extraction and cloud point preconcentration as sample preparation strategies for cobalt determination in biological materials by thermospray flame furnace atomic absorption spectrometry [J].
Donati, GL ;
Nascentes, CC ;
Nogueira, ARA ;
Arruda, MAZ ;
Nóbrega, JS .
MICROCHEMICAL JOURNAL, 2006, 82 (02) :189-195
[10]   DETERMINATION OF CADMIUM IN URINE BY CONTINUUM SOURCE ATOMIC-ABSORPTION SPECTROMETRY [J].
FERNANDO, R ;
JONES, BT ;
ENNEVER, FK .
APPLIED SPECTROSCOPY, 1993, 47 (10) :1696-1699