Non-invasive blood pressure measurement based on the electronic palpation method

被引:0
作者
Nissilä, S [1 ]
Sorvisto, M [1 ]
Sorvoja, H [1 ]
Vieri-Gashi, E [1 ]
Myllylä, R [1 ]
机构
[1] Univ Oulu, Dept Elect Engn, FIN-90570 Oulu, Finland
来源
PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND | 1998年 / 20卷
关键词
blood pressure; non-invasive; electronic palpation; accuracy;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The most commonly used methods of non-invasive blood pressure monitoring are the auscultation method and the oscillometric method. Although both methods are generally accepted and widely used, they are reportedly inaccurate and irreproducible in terms of specific hypertension screening and control. In this paper we present a new electronic palpation method based on an arm cuff and a wrist watch type pulse sensor, which we have developed and tested. The results show that this method is more accurate than the auscultation and oscillometric methods. The difference relative to an intra-arterial measurement was -0.8+/-4.6 mmHg for systolic values and -1.5+/-5.0 mmHg for diastolic values. Moreover, the correlation coefficient of 0.81 was higher than the corresponding figures for the auscultation and oscillometric methods: 0.60 and 0.55, respectively.
引用
收藏
页码:1723 / 1726
页数:4
相关论文
共 50 条
[41]   Innovative continuous non-invasive cuffless blood pressure monitoring based on photoplethysmography technology [J].
Ruiz-Rodriguez, Juan C. ;
Ruiz-Sanmartin, Adolf ;
Ribas, Vicent ;
Caballero, Jesus ;
Garcia-Roche, Alejandra ;
Riera, Jordi ;
Nuvials, Xavier ;
de Nadal, Miriam ;
de Sola-Morales, Oriol ;
Serra, Joaquim ;
Rello, Jordi .
INTENSIVE CARE MEDICINE, 2013, 39 (09) :1618-1625
[42]   Calibration accuracy of hospital-based non-invasive blood pressure measuring devices [J].
de Greeff, A. ;
Lorde, I. ;
Wilton, A. ;
Seed, P. ;
Coleman, A. J. ;
Shennan, A. H. .
JOURNAL OF HUMAN HYPERTENSION, 2010, 24 (01) :58-63
[43]   Non-invasive pressure measurement based on magneto-mechanical effects [J].
Zeng, Zhoumo ;
Zhao, Chengwu ;
Huang, Xinjing ;
Li, Jian ;
Chen, Shili .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (09)
[44]   Non-invasive Blood Glucose Measurement Based on ATR Infrared Spectroscopy [J].
Ishizawa, Hiroaki ;
Muro, Akinobu ;
Takano, Tomohiro ;
Honda, Kazuya ;
Kanai, Hiroyuki .
2008 PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-7, 2008, :292-295
[45]   Comparison of non-invasive and invasive blood pressure in aeromedical care [J].
McMahon, N. ;
Hogg, L. A. ;
Corfield, A. R. ;
Exton, A. D. .
ANAESTHESIA, 2012, 67 (12) :1343-1347
[46]   A review of machine learning techniques in photoplethysmography for the non-invasive cuff-less measurement of blood pressure [J].
El-Hajj, C. ;
Kyriacou, P. A. .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 58
[47]   Continuous non-invasive measurement of mean blood pressure in fingers by volume-clamp and differential oscillometric method [J].
Jagomagi, K ;
Talts, J ;
Raamat, R ;
Lansimies, E .
CLINICAL PHYSIOLOGY, 1996, 16 (05) :551-560
[48]   Continuous Non-invasive Blood Pressure Monitoring Based on Applanation Tonometry [J].
Ariyadamrogkwan, Chollitha ;
Chitsakul, Kitiphol ;
Treetriluxana, Suradaj .
2014 FOURTH JOINT INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONIC AND ELECTRICAL ENGINEERING (JICTEE 2014), 2014,
[49]   Evaluation of agreement between invasive and non-invasive blood pressure measurement using the PetMAP™ device in rabbits [J].
Sredensek, Jerneja ;
Zel, Jurij ;
Rocchi, Attilio ;
Gasparik-Kuels, Nina .
FRONTIERS IN VETERINARY SCIENCE, 2023, 10
[50]   THE MEAN MACHINE; ACCURATE NON-INVASIVE BLOOD PRESSURE MEASUREMENT IN THE CRITICALLY ILL PATIENT [J].
Muecke, Sandy ;
Bersten, Andrew ;
Plummer, John .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2009, 23 (05) :283-297