Non-invasive blood pressure measurement based on the electronic palpation method

被引:0
作者
Nissilä, S [1 ]
Sorvisto, M [1 ]
Sorvoja, H [1 ]
Vieri-Gashi, E [1 ]
Myllylä, R [1 ]
机构
[1] Univ Oulu, Dept Elect Engn, FIN-90570 Oulu, Finland
来源
PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND | 1998年 / 20卷
关键词
blood pressure; non-invasive; electronic palpation; accuracy;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The most commonly used methods of non-invasive blood pressure monitoring are the auscultation method and the oscillometric method. Although both methods are generally accepted and widely used, they are reportedly inaccurate and irreproducible in terms of specific hypertension screening and control. In this paper we present a new electronic palpation method based on an arm cuff and a wrist watch type pulse sensor, which we have developed and tested. The results show that this method is more accurate than the auscultation and oscillometric methods. The difference relative to an intra-arterial measurement was -0.8+/-4.6 mmHg for systolic values and -1.5+/-5.0 mmHg for diastolic values. Moreover, the correlation coefficient of 0.81 was higher than the corresponding figures for the auscultation and oscillometric methods: 0.60 and 0.55, respectively.
引用
收藏
页码:1723 / 1726
页数:4
相关论文
共 50 条
  • [21] Non-Invasive Blood Pressure Measurement Using A Mobile Phone Camera
    Zhang, Yuxuan
    Zhang, Xiao
    Du, Jinlian
    2022 IEEE CONFERENCE ON COMPUTATIONAL INTELLIGENCE IN BIOINFORMATICS AND COMPUTATIONAL BIOLOGY (IEEE CIBCB 2022), 2022, : 11 - 16
  • [22] From Korotkoff and Marey to automatic non-invasive oscillometric blood pressure measurement: does easiness come with reliability?
    Benmira, A.
    Perez-Martin, A.
    Schuster, I.
    Aichoun, I.
    Coudray, S.
    Bereksi-Reguig, F.
    Dauzat, M.
    EXPERT REVIEW OF MEDICAL DEVICES, 2016, 13 (02) : 179 - 189
  • [23] Measurement of Blood Pressure via a Skin-Mounted, Non-Invasive Pressure Sensor
    Li, Shupeng
    Park, Yoonseok
    Luan, Haiwen
    Wang, Heling
    Kwon, Kyeongha
    Rogers, John A.
    Huang, Yonggang
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 2021, 88 (10):
  • [24] Review of non-invasive blood pressure measurement in animals: Part 2-Evaluation of the performance of non-invasive devices
    Skelding, Alicia
    Valverde, Alexander
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2020, 61 (05): : 481 - 498
  • [25] Can Currently Available Non-invasive Continuous Blood Pressure Monitors Replace Invasive Measurement With an Arterial Catheter?
    Gore, Payton
    Liu, Hong
    Bohringer, Christian
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (02)
  • [26] An Ultrasound-Based Non-Invasive Blood Pressure Estimation Method Based on Optimal Vascular Wall Tracking Position
    Liu, Liyuan
    Geng, Xingguang
    Yao, Fei
    Zhang, Yitao
    Zhang, Haiying
    Wang, Yunfeng
    Zheng, Zhaoying
    IEEE ACCESS, 2025, 13 : 17132 - 17149
  • [27] Non-invasive blood pressure measurement: values, problems and applicability in the common marmoset (Callithrix jacchus)
    Mietsch, M.
    Einspanier, A.
    LABORATORY ANIMALS, 2015, 49 (03) : 241 - 250
  • [28] Continuous Non-Invasive Blood Pressure Measurement Using Pulse Transit Time in Children and Adolescents
    Zagrada, Elena
    Krickau, Tobias
    Rascher, Wolfgang
    KLINISCHE PADIATRIE, 2019, 231 (02): : 67 - 73
  • [29] Reliability of non-invasive blood pressure measurement during heavy resistance exercise: A pilot study
    Ipsen, K.
    Couppe, C.
    Neergaard, C.
    Prescott, E. I.
    Magnusson, S. P.
    Dall, C. H.
    TRANSLATIONAL SPORTS MEDICINE, 2018, 1 (02) : 89 - 94
  • [30] Continuous Non-Invasive Blood Pressure Monitoring: A Methodological Review on Measurement Techniques
    Le, Tai
    Ellington, Floranne
    Lee, Tao-Yi
    Vo, Khuong
    Khine, Michelle
    Krishnan, Sandeep Kumar
    Dutt, Nikil
    Cao, Hung
    IEEE ACCESS, 2020, 8 : 212478 - 212498