Non-invasive blood pressure measurement based on the electronic palpation method

被引:0
|
作者
Nissilä, S [1 ]
Sorvisto, M [1 ]
Sorvoja, H [1 ]
Vieri-Gashi, E [1 ]
Myllylä, R [1 ]
机构
[1] Univ Oulu, Dept Elect Engn, FIN-90570 Oulu, Finland
来源
PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND | 1998年 / 20卷
关键词
blood pressure; non-invasive; electronic palpation; accuracy;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The most commonly used methods of non-invasive blood pressure monitoring are the auscultation method and the oscillometric method. Although both methods are generally accepted and widely used, they are reportedly inaccurate and irreproducible in terms of specific hypertension screening and control. In this paper we present a new electronic palpation method based on an arm cuff and a wrist watch type pulse sensor, which we have developed and tested. The results show that this method is more accurate than the auscultation and oscillometric methods. The difference relative to an intra-arterial measurement was -0.8+/-4.6 mmHg for systolic values and -1.5+/-5.0 mmHg for diastolic values. Moreover, the correlation coefficient of 0.81 was higher than the corresponding figures for the auscultation and oscillometric methods: 0.60 and 0.55, respectively.
引用
收藏
页码:1723 / 1726
页数:4
相关论文
共 50 条
  • [1] Advances in Non-Invasive Blood Pressure Measurement Techniques
    Panula, Tuukka
    Sirkia, Jukka-Pekka
    Wong, David
    Kaisti, Matti
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2023, 16 : 424 - 438
  • [2] Advances in Non-Invasive Blood Pressure Measurement Techniques
    Panula, Tuukka
    Sirkia, Jukka-Pekka
    Wong, David
    Kaisti, Matti
    IEEE REVIEWS IN BIOMEDICAL ENGINEERING, 2023, 16 : 424 - 438
  • [3] Anomaly detection concept for a non-invasive blood pressure measurement method in the ear
    Diehl, Matthias
    Teichmann, Tobias
    Zeilfelder, Jennifer
    Stork, Wilhelm
    2021 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS 2021), 2021,
  • [4] Non-invasive measurement of blood pressure and prevalence of blood pressure anomalies in dogs
    Gaur, T
    Varshney, JP
    INDIAN JOURNAL OF ANIMAL SCIENCES, 2002, 72 (01) : 68 - 69
  • [5] A Comparison of Non-Invasive Blood Pressure Measurement Strategies with Intra-Arterial Measurement
    Rebesco, Matthew R.
    Pinkston, M. Cornelia
    Smyrnios, Nicholas A.
    Weisberg, Stacy N.
    PREHOSPITAL AND DISASTER MEDICINE, 2020, 35 (05) : 516 - 523
  • [6] Method and device for non-invasive blood glucose measurement
    Amerov, AK
    Jeon, KJ
    Kim, YJ
    Yoon, G
    OPTICAL DIAGNOSTICS OF BIOLOGICAL FLUIDS IV, PROCEEDINGS OF, 1999, 3599 : 33 - 42
  • [7] Accuracy of non-invasive intracranial pressure measurement
    Seddighi, Amir Saied
    Zadeh, Alireza Moqareh
    Seddighi, Afsoun
    Zali, Alireza
    CENTRAL EUROPEAN JOURNAL OF MEDICINE, 2012, 7 (02): : 169 - 175
  • [8] The System of Indicators of the Continuous Non-Invasive Blood Pressure Measurement
    Timokhov, Gennady, V
    Semenova, Evgeniia A.
    Pivovarov, Vladimir V.
    PROCEEDINGS OF THE 2021 IEEE CONFERENCE OF RUSSIAN YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING (ELCONRUS), 2021, : 1860 - 1864
  • [9] Non-invasive blood pressure measurement in animals: Part 1-Techniques for measurement and validation of non-invasive devices
    Skelding, Alicia
    Valverde, Alexander
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2020, 61 (04): : 368 - 374
  • [10] Concept for a Permanent, Non-Invasive Blood Pressure Measurement in the Ear
    Zeilfelder, Jennifer
    Diehl, Matthias
    Pylatiuk, Christian
    Stork, Wilhelm
    2019 IEEE EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL & HEALTH INFORMATICS (BHI), 2019,