Progressive collapse resistance of precast beam-column sub-assemblages with engineered cementitious composites

被引:95
作者
Kang, Shao-Bo [1 ]
Tan, Kang Hai [1 ]
Yang, En-Hua [1 ]
机构
[1] Nanyang Technol Univ, Sch Civil & Environm Engn, Singapore 639798, Singapore
关键词
Precast concrete structures; ECC; Column removal scenarios; CAA; Catenary action; STRAIN-HARDENING BEHAVIOR; SIMPLIFIED INVERSE METHOD; CONCRETE; ECC;
D O I
10.1016/j.engstruct.2015.04.034
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper addresses the experimental investigation on the behaviour of precast concrete beam-column sub-assemblages with engineered cementitious composites (ECC) in structural topping and beam-column joints under middle column removal scenarios. Sub-assemblages comprising of a double-span beam and a middle beam-column joint were laterally connected to a rigid frame on one side and a reaction wall on the other side through load cells. Quasi-static vertical loading was imposed onto the middle column. Compressive arch action (CAA) and catenary action developed sequentially in the bridging beam with increasing middle joint displacement. Unlike conventional concrete, structural topping made of ECC exhibited multi-cracking behaviour with limited crack width and compatible deformations with embedded reinforcement at the initial stage of CAA. However, beyond the tensile strain capacity of ECC, major cracks formed near the face of the end column stub, causing severe strain localisation of the top longitudinal reinforcement in the beam. Besides, at large deformations, high tensile strain capacity of ECC actually hindered the development of flexural cracks in the beam, in particular, at the curtailment point of the top longitudinal reinforcement near the end column stub, thereby substantially reducing the deformation capacity of sub-assemblages. Eventually, fracture of beam longitudinal reinforcement at the face of end column stub led to failure of beam-column sub-assemblages. Through linear variable differential transducers mounted in the plastic hinge region, rotation capacity of plastic hinge could be calculated at the catenary action stage. Finally, the effectiveness of ECC on mitigating progressive collapse was examined to gain a better insight into its potential structural applications. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:186 / 200
页数:15
相关论文
共 31 条
[1]  
[Anonymous], 2008, Concrete Engineering, P82
[2]  
[Anonymous], FIB B
[3]  
[Anonymous], 2004, EN 1992-1-1, P225
[4]  
CAE, 1999, GUID US PREC CONCR B
[5]  
Department of Defence (DoD), 2013, UFC 4-023-03
[6]  
FIB, 2002, FIB B, V19
[7]  
Fischer G, 2003, ACI STRUCT J, V100, P25
[8]  
Fischer G, 2002, ACI STRUCT J, V99, P104
[9]   Behavior of Concrete and ECC Structures under Simulated Earthquake Motion [J].
Gencturk, Bora ;
Elnashai, Amr S. ;
Lepech, Michael D. ;
Billington, Sarah .
JOURNAL OF STRUCTURAL ENGINEERING, 2013, 139 (03) :389-399
[10]  
GSA, 2003, Progressive collapse analysis and design guidelines for new federal office buildings and major modernization projects