Comparison of oscillometric, non-invasive and invasive arterial pressure monitoring in patients undergoing laparoscopic bariatric surgery - a secondary analysis of a prospective observational study

被引:4
作者
Hansen, Jonathan [1 ]
Pohlmann, Markus [1 ]
Beckmann, Jan H. [2 ]
Klose, Phil [1 ]
Gruenewald, Matthias [1 ]
Renner, Jochen [3 ]
Lorenzen, Ulf [1 ]
Elke, Gunnar [1 ]
机构
[1] Univ Med Ctr Schleswig Holstein, Dept Anesthesiol & Intens Care Med, Campus Kiel1, D-24105 Kiel, Germany
[2] Univ Med Ctr Schleswig Holstein, Dept Gen & Abdominal Surg, Campus Kiel, D-24105 Kiel, Germany
[3] Municipal Hosp Kiel, Dept Anesthesiol & Intens Care Med, D-24116 Kiel, Germany
关键词
Blood pressure; Finger-cuff; Non-invasive monitoring; Nexfin; Clear sight; Obesity; Bariatric surgery; Vascular unloading technique; BLOOD-PRESSURE; RISK; VALIDATION; AGREEMENT; ACCURACY; STANDARD; SYSTEM; IMPACT; DEVICE; ARM;
D O I
10.1186/s12871-022-01619-3
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Oscillometric, non-invasive blood pressure measurement (NIBP) is the first choice of blood pressure monitoring in the majority of low and moderate risk surgeries. In patients with morbid obesity, however, it is subject to several limitations. The aim was to compare arterial pressure monitoring by NIBP and a non-invasive finger-cuff technology (Nexfin (R) ) with the gold-standard invasive arterial pressure (IAP). Methods: In this secondary analysis of a prospective observational, single centre cohort study, systolic (SAP), diastolic (DAP) and mean arterial pressure (MAP) were measured at 16 defined perioperative time points including posture changes, fluid bolus administration and pneumoperitoneum (PP) in patients undergoing laparoscopic bariatric surgery. Absolute arterial pressures by NIBP, Nexfin (R) and IAP were compared using correlation and Bland Altman analyses. Interchangeability was defined by a mean difference <= 5 mmHg (SD <= 8 mmHg). Percentage error (PE) was calculated as an additional statistical estimate. For hemodynamic trending, concordance rates were analysed according to the Critchley criterion. Results: Sixty patients (mean body mass index of 49.2 kg/m(2)) were enrolled and data from 56 finally analysed. Pooled blood pressure values of all time points showed a significant positive correlation for both NIPB and Nexfin (R) versus IAP. Pooled PE for NIBP versus IAP was 37% (SAP), 35% (DAP) and 30% (MAP), for Nexfin versus IAP 23% (SAP), 26% (DAP) and 22% (MAP). Correlation of MAP was best and PE lowest before induction of anesthesia for NIBP versus IAP (r = 0.72; PE 24%) and after intraoperative fluid bolus administration for Nexfin (R) versus IAP (r = 0.88; PE: 17.2%). Concordance of MAP trending was 90% (SAP 85%, DAP 89%) for NIBP and 91% (SAP 90%, DAP 86%) for Nexfin (R). MAP trending was best during intraoperative ATP positioning for NIBP (97%) and at induction of anesthesia for Nexfin (R) (97%). Conclusion: As compared with IAP, interchangeability of absolute pressure values could neither be shown for NIBP nor Nexfin (R), however, NIBP showed poorer overall correlation and precision. Overall trending ability was generally high with Nexfin (R) surpassing NIBP. Nexfin (R) may likely render individualized decision-making in the management of different hemodynamic stresses during laparoscopic bariatric surgery, particularly where NIBP cannot be reliably established.
引用
收藏
页数:12
相关论文
共 50 条
[31]   Non-invasive continuous blood pressure monitoring (ClearSight™ system) during shoulder surgery in the beach chair position: a prospective self-controlled study [J].
Chachula, Konrad ;
Lieb, Florian ;
Hess, Florian ;
Welter, Joellen ;
Graf, Nicole ;
Dullenkopf, Alexander .
BMC ANESTHESIOLOGY, 2020, 20 (01)
[32]   Accuracy and trending of non-invasive oscillometric blood pressure monitoring at the wrist in obese patients [J].
Mostafa, Maha M. A. ;
Hasanin, Ahmed M. ;
Alhamade, Fatema ;
Abdelhamid, Bassant ;
Safina, Ahmed G. ;
Kasem, Sahar M. ;
Hosny, Osama ;
Mahmoud, Mohamed ;
Fouad, Eman ;
Rady, Ashraf ;
Amin, Sarah M. .
ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2020, 39 (02) :221-227
[33]   Central Versus Peripheral Arterial Pressure Monitoring in Patients Undergoing Cardiac Surgery: A Prospective Observational Study [J].
Jacquet-Lagreze, Matthias ;
Bredeche, Faustine ;
Louyot, Claire ;
Pozzi, Matteo ;
Grinberg, Daniel ;
Flagiello, Michele ;
Portran, Philippe ;
Ruste, Martin ;
Schweizer, Remi ;
Fellahi, Jean-Luc .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 37 (09) :1631-1638
[34]   Comparison of invasive and non-invasive measurements of cardiac index and systemic vascular resistance in living-donor liver transplantation: a prospective, observational study [J].
Cho, Hye-Yeon ;
Lee, Ho-Jin ;
Hwang, In Eob ;
Lee, Hyung-Chul ;
Kim, Won Ho ;
Yang, Seong-Mi .
BMC ANESTHESIOLOGY, 2023, 23 (01)
[35]   A Comparison of Non-Invasive Blood Pressure Measurement Strategies with Intra-Arterial Measurement [J].
Rebesco, Matthew R. ;
Pinkston, M. Cornelia ;
Smyrnios, Nicholas A. ;
Weisberg, Stacy N. .
PREHOSPITAL AND DISASTER MEDICINE, 2020, 35 (05) :516-523
[36]   Non-invasive measurement of pulse pressure variation using a finger-cuff method in obese patients having laparoscopic bariatric surgery [J].
Flick, Moritz ;
Schumann, Roman ;
Hoppe, Phillip ;
Bonney, Iwona ;
Wesselink, Wilbert ;
Saugel, Bernd .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2021, 35 (06) :1341-1347
[37]   Smartphone-Based versus Non-Invasive Automatic Oscillometric Brachial Cuff Blood Pressure Measurements: A Prospective Method Comparison Volunteer Study [J].
Delmotte, Lila ;
Desebbe, Olivier ;
Alexander, Brenton ;
Kouz, Karim ;
Coeckelenbergh, Sean ;
Schoettker, Patrick ;
Turgay, Tuna ;
Joosten, Alexandre .
JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (01)
[38]   Comparison between non-invasive methods and liver histology to stratify liver fibrosis in obese patients submitted to bariatric surgery [J].
Didone Filho, Celso Nilo ;
Reginatto, Cleiton Jonei ;
Ivantes, Claudia Alexandra Pontes ;
Strobel, Rodrigo ;
Percicote, Ana Paula ;
Petenusso, Marcio ;
da Silva, Cicero Jordan R. Sobreira ;
Benjamim, Cicero Jonas R. ;
Radominski, Rosana Bento .
OBESITY RESEARCH & CLINICAL PRACTICE, 2021, 15 (02) :152-156
[39]   Comparison of non-invasive blood pressure monitoring using modified arterial applanation tonometry with intra-arterial measurement [J].
Harju, Jarkko ;
Vehkaoja, Antti ;
Kumpulainen, Pekka ;
Campadello, Stefano ;
Lindroos, Ville ;
Yli-Hankala, Arvi ;
Oksala, Niku .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (01) :13-22
[40]   Non-invasive assessment of arterial stiffness using oscillometric blood pressure measurement [J].
Komine, Hidehiko ;
Asai, Yoshiyuki ;
Yokoi, Takashi ;
Yoshizawa, Mutsuko .
BIOMEDICAL ENGINEERING ONLINE, 2012, 11