Spontaneous long-term changes of corneal power and astigmatism after suture removal after penetrating keratoplasty using a regression model

被引:18
作者
Langenbucher, A
Naumann, GOH
Seitz, B
机构
[1] Univ Erlangen Nurnberg, Augenklin, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Poliklin, D-91054 Erlangen, Germany
关键词
D O I
10.1016/j.ajo.2005.01.038
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the diagnosis,based spontaneous long-term changes in corneal power and refraction with a regression model in the all,sutures-out time period following non-mechanical penetrating keratoplasty (PK). DESIGN: Retrospective non-randomized clinical trial. METHODS. SETTING. Clinical practice. STUDY POPULATION. 147 eyes [47 Fuchs dystrophy (FD); 100 keratoconus (KC)] were studied after suture removal in this retrospective longitudinal study. MAIN OUTCOME MEASURES: Zeiss keratometry [equivalent power (KEQ) and astigmatism (KAST)], corneal topography analysis [equivalent power (TEQ) and astigmatism (TAST)], and subjective refractometry [spherical equivalent (SEQ) and refractive cylinder (RAST)] were assessed in at least three up to 16 ophthalmologic examinations in the all-sutures-out time period. OBSERVATION PROCEDURE. The time course of each target variable was analyzed in a longitudinal manner (time interval a: 12 months) separately for each patient with a linear regression model. RESULTS: Post-keratoplasty follow,up ranged from 31 months to 10.3 years. In the linear regression model, the annual change in FD/KC showed an increase/a decrease in KEQ (0.29 +/- 0.50/-0.63 +/- 0.46 diopters, P = .02) and an increase/a decrease in TEQ (0.37 +/- 0.54/-0.69 +/- 0.49 diopters, P = .04) corresponding to a decrease/an increase in SEQ (-0.31 +/- 0.47/0.63 +/- 0.43 diopters, P = .02). KAST/TAST/RAST showed a minimal annual de, crease (-0.06 +/- 0.41/-0.05 +/- 0.45/-0.06 +/- 0.41 diopters) in FD but an increase in KC (0.46 +/- 0.41/0-51 +/- 0.43/0-46 +/- 0.38 diopters) (P = .05/0.06/0.12). CONCLUSIONS: In the follow,up after post-keratoplasty suture removal, patients with FD/KC tend to develop a spontaneous myopic shift (steepening of the cornea)/hyperopic shift (flattening of the cornea). In contrast with those with FD, patients with KC should be counseled on the fact that astigmatism may increase again over time after suture removal.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 33 条
[1]   Visual function after penetrating keratoplasty for keratoconus: a prospective longitudinal evaluation [J].
Brahma, A ;
Ennis, F ;
Harper, R ;
Ridgway, A ;
Tullo, A .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2000, 84 (01) :60-66
[2]   Penetrating keratoplasty for keratoconus [J].
Brierly, SC ;
Izquierdo, L ;
Mannis, MJ .
CORNEA, 2000, 19 (03) :329-332
[3]   Corneal transplant for keratoconus: Results in early and late disease [J].
Buzard, KA ;
Fundingsland, BR .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (03) :398-406
[4]  
COHEN KL, 1984, INVEST OPHTH VIS SCI, V25, P1226
[5]   Comparison of suture-in and suture-out postkeratoplasty astigmatism with single running suture or combined running and interrupted sutures [J].
Filatov, V ;
Alexandrakis, G ;
Talamo, JH ;
Steinert, RF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1996, 122 (05) :696-700
[6]  
HOFFMANN F, 1976, KLIN MONATSBL AUGENH, V169, P584
[7]   Endothelium and pachymetry of clear corneal grafts 15 to 33 years after penetrating keratoplasty [J].
Kus, MM ;
Seitz, B ;
Langenbucher, A ;
Naumann, GOH .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 127 (05) :600-602
[8]   Corneal endothelial cell loss after nonmechanical penetrating keratoplasty depends on diagnosis: a regression analysis [J].
Langenbucher, A ;
Seitz, B ;
Nguyen, NX ;
Naumann, GOH .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2002, 240 (05) :387-392
[9]   Regression analysis of corneal endothelium after nonmechanical penetrating keratoplasty [J].
Langenbucher, A ;
Nguyen, NX ;
Kus, MM ;
Blüthner, K ;
Küchle, M ;
Seitz, B .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2000, 216 (06) :393-399
[10]   Penetrating keratoplasty for keratoconus: Visual outcome and success [J].
Lim, L ;
Pesudovs, K ;
Coster, DJ .
OPHTHALMOLOGY, 2000, 107 (06) :1125-1131