GPU-accelerated study of the inertial cavitation threshold in viscoelastic soft tissue using a dual-frequency driving signal

被引:19
作者
Filonets, Tatiana [1 ,2 ]
Solovchuk, Maxim [1 ,2 ,3 ]
机构
[1] Natl Taiwan Univ, Dept Engn Sci & Ocean Engn, 1,Sect 4,Roosevelt Rd, Taipei 10617, Taiwan
[2] Natl Hlth Res Inst, Inst Biomed Engn & Nanomed, 35,Keyan Rd, Taipei 35053, Taiwan
[3] Natl Chung Hsing Univ, Tissue Engn & Regenerat Med, 145, Xingda Rd, Taichung 40227, Taiwan
关键词
Acoustic cavitation in soft tissue; Inertial cavitation threshold; Dual-frequency driving signal; High-intensity focused ultrasound; INTENSITY FOCUSED ULTRASOUND; DYNAMICS; TEMPERATURE; THERAPY; MICROBUBBLES; PROPAGATION; SIMULATION; ABLATION; DELIVERY; WAVES;
D O I
10.1016/j.ultsonch.2022.106056
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Inertial cavitation thresholds under two forms of ultrasonic excitation (the single-and dual-frequency ultrasound modes) are studied numerically. The Gilmore-Akulichev model coupled with the Zener viscoelastic model is used to model the bubble dynamics. The threshold pressures are determined with two criteria, one based on the bubble radius and the other on the bubble collapse speed. The threshold behavior is investigated for different initial bubble sizes, acoustic signal modes, frequencies, tissue viscosities, tissue elasticities, and all their combinations. Due to the large number of parameters and their many combinations (around 1.5 billion for each threshold criterion), all simulations were executed on graphics processing units to speed up the calculations. We used our own code written in the C++ and CUDA C languages. The results obtained demonstrate that using the dual-frequency signal mode can help to reduce the inertial cavitation threshold (in comparison to the single frequency mode). The criterion based on the bubble size gives a lower threshold than the criterion using the bubble collapse speed. With an increase of the elasticity, the threshold pressure also increases, whereas changing the viscosity has a very small impact on the optimal threshold, unlike the elasticity. A detailed analysis of the optimal ultrasound frequencies for a dual-frequency driving signal found that for viscosities less than 0.02 Pa.s, the first optimal frequency, in general, is much smaller than the second optimal frequency, which can reach 1 MHz. However, for high viscosities, both optimal frequencies are similar and varied in the range 0.01-0.05 MHz. Overall, this study presents a detailed analysis of inertial cavitation in soft tissue under dual-frequency signal excitation. It may be helpful for the further development of different applications of biomedical ultrasound.
引用
收藏
页数:14
相关论文
共 51 条
[1]   GAUGING THE LIKELIHOOD OF CAVITATION FROM SHORT-PULSE, LOW-DUTY CYCLE DIAGNOSTIC ULTRASOUND [J].
APFEL, RE ;
HOLLAND, CK .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (02) :179-185
[2]   The characterization of acoustic cavitation bubbles - An overview [J].
Ashokkumar, Muthupandian .
ULTRASONICS SONOCHEMISTRY, 2011, 18 (04) :864-872
[3]   The detection and control of stable and transient acoustic cavitation bubbles [J].
Ashokkumar, Muthupandian ;
Lee, Judy ;
Iida, Yasuo ;
Yasui, Kyuichi ;
Kozuka, Teruyuki ;
Tuziuti, Toru ;
Towata, Atsuya .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2009, 11 (43) :10118-10121
[4]   Suppressing chaotic oscillations of a spherical cavitation bubble through applying a periodic perturbation [J].
Behnia, Sohrab ;
Sojahrood, Amin Jafari ;
Soltanpoor, Wiria ;
Jahanbakhsh, Okhtay .
ULTRASONICS SONOCHEMISTRY, 2009, 16 (04) :502-511
[5]   Sonoluminescence and acoustic cavitation [J].
Choi, Pak-Kon .
JAPANESE JOURNAL OF APPLIED PHYSICS, 2017, 56 (07)
[6]   Frequency, pulse length, and the mechanical index [J].
Church, CC .
ACOUSTICS RESEARCH LETTERS ONLINE-ARLO, 2005, 6 (03) :162-168
[7]   A THEORETICAL STUDY OF INERTIAL CAVITATION FROM ACOUSTIC RADIATION FORCE IMPULSE IMAGING AND IMPLICATIONS FOR THE MECHANICAL INDEX [J].
Church, Charles C. ;
Labuda, Cecille ;
Nightingale, Kathryn .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (02) :472-485
[8]   Applications of acoustics and cavitation to noninvasive therapy and drug delivery [J].
Coussios, Constantin C. ;
Roy, Ronald A. .
ANNUAL REVIEW OF FLUID MECHANICS, 2008, 40 (395-420) :395-420
[9]   High-performance multi-GPU solver for describing nonlinear acoustic waves in homogeneous thermoviscous media [J].
Diaz, Manuel A. ;
Solovchuk, Maxim A. ;
Sheu, Tony W. H. .
COMPUTERS & FLUIDS, 2018, 173 :195-205
[10]   A conservative numerical scheme for modeling nonlinear acoustic propagation in thermoviscous homogeneous media [J].
Diaz, Manuel A. ;
Solovchuk, Maxim A. ;
Sheu, Tony W. H. .
JOURNAL OF COMPUTATIONAL PHYSICS, 2018, 363 :200-230