T2-weighted MRI of the uterus: Fast spin echo vs. breath-hold fast spin echo

被引:0
|
作者
Ascher, SM [1 ]
O'Malley, J [1 ]
Semelka, RC [1 ]
Patt, RH [1 ]
Rajan, S [1 ]
Thomasson, D [1 ]
机构
[1] Georgetown Univ, Med Ctr, Dept Radiol, Washington, DC 20007 USA
来源
关键词
uterus; MR; pelvis; magnetic resonance rapid imaging;
D O I
10.1002/(SICI)1522-2586(199903)9:3<384::AID-JMRI4>3.0.CO;2-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study compared one routine Ta-weighted fast spin echo (T2FSE) sequence with a breath-hold T2FSE (BH T2FSE) sequence of the female pelvis for image quality, uterine anatomy, lesion detection, and signal intensity measurements. Thirty-two consecutive women (mean age 41.7 years) were imaged at 1.5 T with one high-resolution routine T2FSE sequence and one BH T2FSE sequence in the sagittal plane as part of comprehensive pelvic magnetic resonance imaging. The different image sets were rated separately for imaging characteristics (overall image quality, uterine anatomy definition, lesion detection, and free fluid conspicuity) and then compared side by side. The image sets were also compared for artifacts (ghosting, blurring, pulsatility, and chemical shift misregistration). Signal-to-noise (S/N) and signal difference-to-noise (SD/N) ratios were calculated for the different uterine zones, uterine abnormalities, free fluid, rectus abdominis muscle, and bladder. Contrast-to-noise ratios (CNRs) were calculated for uterine abnormalities. Twenty-eight uterine abnormalities were detected in 20 patients and included leiomyomata (13 patients), adenomyosis (7 patients), benign endometrial polyps (6 patients), endometrial carcinoma (1 patient), and pregnancy(1 patient). BH T2FSE was superior or equivalent to T2FSE for overall image quality in 23/32 patients (71.8%), uterine anatomy definition in 19/32 patients (59.3%), and lesion detection in 13/20 patients (65%), BH T2FSE performed less well than T2FSE for free fluid conspicuity in 5/5 (100%) patients. BH T2FSE was equivalent to or less affected than T2FSE for ghosting artifact in 24/32 patients (75%) and blurring artifact in 29/32 patients (90.6%). Pulsatility and chemical shift artifacts were not problematic for either image set. S/N and SD/N were higher for all BH T2FSE determinations compared with T2FSE, For the endometrium, junctional zone, myometrium, and bladder, these differences were statistically significant. There were no statistically significant differences for CNR between the two image sets, although BH T2FSE values for leiomyomata, adenomyosis, and abnormal endometria were higher than those calculated for T2FSE, All pathology detected with T2FSE was detected an BH T2FSE despite the breath-hold sequence's inherently poorer spatial resolution compared with the non-breath-hold sequence. BH T2FSE may be able to replace T2FSE for some uterine applications with a substantial time savings, (C) 1999 Wiley-Liss. Inc.
引用
收藏
页码:384 / 390
页数:7
相关论文
共 50 条
  • [1] T2-weighted MRI of the female pelvis: Comparison of breath-hold fast-recovery fast spin-echo and nonbreath-hold fast spin-echo sequences
    Masui, T
    Katayama, M
    Kobayashi, S
    Sakahara, H
    Ito, T
    Nozaki, A
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (06) : 930 - 937
  • [2] Breath-hold fast recovery fast spin echo versus conventional non-breath-hold fast spin echo T2-weighted MR imaging of focal liver lesions
    Tseng, GY
    Thng, CH
    Wong, EH
    Tan, AGS
    Suman, P
    Quek, ST
    Ho, JTS
    Khoo, JKB
    Ooi, LLPJ
    Chow, PKH
    Chung, YFA
    Teh, CSC
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2003, 32 (04) : 450 - 454
  • [3] Fat-suppressed T2-weighted MRI of the liver: Comparison of respiratory-triggered fast spin-echo, breath-hold single-shot fast spin-echo, and breath-hold fast-recovery fast spin-echo sequences
    Katayama, M
    Masui, T
    Kobayashi, S
    Ito, T
    Takahashi, M
    Sakahara, H
    Nozaki, A
    Kabasawa, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 14 (04) : 439 - 449
  • [4] T2-weighted spin-echo MR imaging of the liver: Breath-hold fast spin-echo versus non-breath-hold fast spin-echo images with and without fat suppression
    Soyer, P
    LeNormand, S
    deGivry, SC
    Gueye, C
    Somveille, E
    Scherrer, A
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (03) : 593 - 597
  • [5] Fat-suppressed T2-weighted MR imaging of the liver: Comparison of respiratory triggered fast spin-echo, breath-hold single-shot fast spin-echo and breath-hold fast-recovery fast spin-echo sequences
    Katayama, M
    Masui, T
    Kobayashi, S
    Ito, T
    Sakahara, H
    Nozaki, A
    RADIOLOGY, 2000, 217 : 587 - 587
  • [6] Breath-hold T2-weighted imaging of hepatic lesions by using fast recovery, fast spin-echo sequence
    Kim, T
    Murakami, T
    Takahashi, S
    Hori, M
    Takamura, M
    Nakamura, H
    RADIOLOGY, 2001, 221 : 304 - 305
  • [7] Comparison of breath-hold multishot echo-planar and respiratory triggered fast-spin-echo sequences for T2-weighted MRI of liver lesions
    Yamakado, K
    Sakuma, H
    Murashima, S
    Nakatsuka, A
    Matsumura, K
    Takeda, K
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (02): : 432 - 437
  • [8] Liver: T2-weighted MR imaging with breath-hold fast-recovery optimized fast spin-echo compared with breath-hold half-Fourier and non-breath-hold respiratory-triggered fast spin-echo pulse sequences
    Augui, J
    Vignaux, O
    Argaud, C
    Coste, J
    Gouya, H
    Legmann, P
    RADIOLOGY, 2002, 223 (03) : 853 - 859
  • [9] COMPARISON OF BREATH-HOLD FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES FOR T2-WEIGHTED MR-IMAGING OF LIVER-LESIONS
    RYDBERG, JN
    LOMAS, DJ
    COAKLEY, KJ
    HOUGH, DM
    EHMAN, RL
    RIEDERER, SJ
    RADIOLOGY, 1995, 194 (02) : 431 - 437
  • [10] Fast breath-hold T2-weighted MRI of the kidney by means of half-Fourier single-shot turbo spin echo: Comparison with high resolution turbo spin echo sequence
    Nakayama, Y
    Yamashita, Y
    Matsuno, Y
    Tang, Y
    Namimoto, T
    Kadota, M
    Mitsuzaki, K
    Abe, Y
    Katahira, K
    Arakawa, A
    Takahashi, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (01) : 55 - 60