A FRET based ratiometric fluorescent probe for detection of sulfite in food

被引:37
|
作者
Zhang, Gongxiao [1 ]
Ji, Ruixue [1 ]
Kong, Xiangyu [1 ]
Ning, Fujiao [1 ]
Liu, Aikun [1 ]
Cui, Jichun [2 ]
Ge, Yanqing [1 ]
机构
[1] Taishan Med Univ, Sch Chem & Pharmaceut Engn, Tai An 271016, Shandong, Peoples R China
[2] Liaocheng Univ, Sch Chem & Chem Engn, Liaocheng 252000, Shandong, Peoples R China
关键词
SELECTIVE DETECTION; SO2; DERIVATIVES; BISULFITE; WATER; HG2+; SYSTEM; CELLS; CU2+;
D O I
10.1039/c8ra08967a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new fluorophore pyrido[1,2-a]benzimidazole based ratiometric fluorescent probe for the selective detection of sulfite ions in water was investigated. It shows large (pseudo) Stokes shifts (260 nm), high FRET efficiency, high selectivity and sensitivity. A distinct color change from red to colorless was observed and importantly, it proves to be a convenient and efficient tool to detect the sulfite levels in sugar samples.
引用
收藏
页码:1147 / 1150
页数:4
相关论文
共 50 条
  • [11] A colorimetric and ratiometric fluorescent probe for the rapid and sensitive detection of sulfite in sugar
    Jiang, Xiaoming
    Xu, Junchao
    Zhang, Youlai
    Wang, Hongying
    Zeng, Lintao
    Zhang, Yue
    ANALYTICAL METHODS, 2016, 8 (07) : 1572 - 1576
  • [12] A FRET-based near-infrared ratiometric fluorescent probe for detection of mitochondria biothiol
    Wang, Lu
    Wang, Jianbo
    Xia, Shuai
    Wang, Xinxin
    Yu, Yating
    Zhou, Hongwei
    Liu, Haiying
    TALANTA, 2020, 219 (219)
  • [13] A ratiometric fluorescent probe for detection of exogenous mitochondrial SO2 based on a FRET mechanism
    Xu, Zhiyang
    Chen, Zhen
    Liu, Aikun
    Ji, Ruixue
    Cao, Xiaoqun
    Ge, Yanqing
    RSC ADVANCES, 2019, 9 (16) : 8943 - 8948
  • [14] A novel FRET-based ratiometric fluorescent probe for highly sensitive detection of hydrogen sulfide
    Huang, Kunzhu
    Yu, Lun
    Xu, Pengfei
    Zhang, Xintong
    Zeng, Wenbin
    RSC ADVANCES, 2015, 5 (23): : 17797 - 17801
  • [15] A FRET-based ratiometric fluorescent probe for hydrogen polysulfide detection in living cells and zebrafish
    Liu, Teng
    Peng, Qiyao
    Wang, Junyi
    Yu, Chao
    Huang, Xuekuan
    Luo, Quan
    Zeng, Yajun
    Hou, Yi
    Zhang, Yuan
    Luo, Aiming
    Zou, Zhaoxia
    Chen, Meizi
    Peng, Yongbo
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 267
  • [16] A FRET-Based Near-Infrared Fluorescent Probe for Ratiometric Detection of Cysteine in Mitochondria
    Xia, Shuai
    Zhang, Yibin
    Fang, Mingxi
    Mikesell, Logan
    Steenwinkel, Tessa E.
    Wan, Shulin
    Phillips, Tyler
    Luck, Rudy L.
    Werner, Thomas
    Liu, Haiying
    CHEMBIOCHEM, 2019, 20 (15) : 1986 - 1994
  • [17] A colorimetric and ratiometric fluorescent probe for sulfite based on an intramolecular cleavage mechanism
    Hou, Peng
    Chen, Song
    Voitchovsky, Kislon
    Song, Xiangzhi
    LUMINESCENCE, 2014, 29 (07) : 749 - 753
  • [18] Mitochondria-targeted ratiometric fluorescent probe based on FRET for bisulfite
    Wu, Wen-Li
    Ma, Han-Lin
    Huang, Miao-Fei
    Miao, Jun-Ying
    Zhao, Bao-Xiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 241 : 239 - 244
  • [19] A highly sulfite-selective ratiometric fluorescent probe based on ESIPT
    Chen, Song
    Hou, Peng
    Wang, Jianxiu
    Song, Xiangzhi
    RSC ADVANCES, 2012, 2 (29): : 10869 - 10873
  • [20] An effective ICT-based and ratiometric fluorescent probe for sensing sulfite
    Zhang, Li-Jie
    Wang, Zhao-Yang
    Cao, Xiang-Jian
    Liu, Jin-Ting
    Zhao, Bao-Xiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 236 : 741 - 748