Non-invasive assessment of human multifidus muscle stiffness using ultrasound shear wave elastography: A feasibility study

被引:51
作者
Moreau, Baptiste [1 ]
Vergari, Claudio [1 ]
Gad, Hisham [1 ,2 ]
Sandoz, Baptiste [1 ]
Skalli, Wafa [1 ]
Laporte, Sebastien [1 ]
机构
[1] Arts & Metiers ParisTech, LBM Inst Biomecan Humaine Georges Charpak, Paris, France
[2] Ctr Hosp Bayeux, Serv Chirurg Orthoped & Traumatol, Bayeux, France
关键词
Elastography; multifidus; muscle; lumbar spine; shear modulus; biomechanics; LOW-BACK-PAIN; MAGNETIC-RESONANCE ELASTOGRAPHY; CROSS-SECTIONAL AREA; LUMBAR MULTIFIDUS; TRANSIENT ELASTOGRAPHY; TISSUE ELASTICITY; IDIOPATHIC SCOLIOSIS; THORACOLUMBAR FASCIA; SKELETAL-MUSCLE; CONTRACTION;
D O I
10.1177/0954411916656022
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
There is a lack of numeric data for the mechanical characterization of spine muscles, especially in vivo data. The multifidus muscle is a major muscle for the stabilization of the spine and may be involved in the pathogenesis of chronic low back pain (LBP). Supersonic shear wave elastography (SWE) has not yet been used on back muscles. The purpose of this prospective study is to assess the feasibility of ultrasound SWE to measure the elastic modulus of lumbar multifidus muscle in a passive stretching posture and at rest with a repeatable and reproducible method. A total of 10 asymptotic subjects (aged 25.5 +/- 2.2 years) participated, 4 females and 6 males. Three operators performed 6 measurements for each of the 2 postures on the right multifidus muscle at vertebral levels L2-L3 and L4-L5. Repeatability and reproducibility have been assessed according to ISO 5725 standard. Intra-class correlation coefficients (ICC) for intra- and inter-observer reliability were rated as both excellent [ICC=0.99 and ICC=0.95, respectively]. Reproducibility was 11% at L2-L3 level and 19% at L4-L5. In the passive stretching posture, shear modulus was significantly higher than at rest (mu<0.05). This preliminary work enabled to validate the feasibility of measuring the shear modulus of the multifidus muscle with SWE. This kind of measurement could be easily introduces into clinical routine like for the medical follow-up of chronic LBP or scoliosis treatments.
引用
收藏
页码:809 / 814
页数:6
相关论文
共 31 条
[1]   Quantitative Assessment of Normal Soft-Tissue Elasticity Using Shear-Wave Ultrasound Elastography [J].
Arda, Kemal ;
Ciledag, Nazan ;
Aktas, Elif ;
Aribas, Bilgin Kadri ;
Kose, Kenan .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (03) :532-536
[2]   Determination of thigh muscle stiffness using magnetic resonance elastography [J].
Bensamoun, SF ;
Ringleb, SI ;
Littrell, L ;
Chen, QS ;
Brennan, M ;
Ehman, RL ;
An, KN .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (02) :242-247
[3]   Supersonic shear imaging: A new technique for soft tissue elasticity mapping [J].
Bercoff, J ;
Tanter, M ;
Fink, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (04) :396-409
[4]   THE APPLIED ANATOMY OF THE THORACOLUMBAR FASCIA [J].
BOGDUK, N ;
MACINTOSH, JE .
SPINE, 1984, 9 (02) :164-170
[5]   Dynamic changes of elasticity, cross-sectional area, and fat infiltration of multifidus at different postures in men with chronic low back pain [J].
Chan, Suk-Tak ;
Fung, Po-Kwan ;
Ng, Nim-Yu ;
Ngan, Tsz-Lung ;
Chong, Man-Yan ;
Tang, Chi-Ngong ;
He, Jun-Feng ;
Zheng, Yong-Ping .
SPINE JOURNAL, 2012, 12 (05) :381-388
[6]   Differences in electromyographic activity in the multifidus muscle and the iliocostalis lumborum between healthy subjects and patients with sub-acute and chronic low back pain [J].
Danneels, LA ;
Coorevits, PL ;
Cools, AM ;
Vanderstraeten, GG ;
Cambier, DC ;
Witvrouw, EE ;
De Cuyper, HJ .
EUROPEAN SPINE JOURNAL, 2002, 11 (01) :13-19
[7]   Effects of three different training modalities on the cross sectional area of the lumbar multifidus muscle in patients with chronic low back pain [J].
Danneels, LA ;
Vanderstraeten, GG ;
Cambier, DC ;
Witvrouw, EE ;
Bourgois, J ;
Dankaerts, W ;
De Cuyper, HJ .
BRITISH JOURNAL OF SPORTS MEDICINE, 2001, 35 (03) :186-191
[8]  
Dresner MA, 2001, J MAGN RESON IMAGING, V13, P269, DOI 10.1002/1522-2586(200102)13:2<269::AID-JMRI1039>3.0.CO
[9]  
2-1
[10]   RELIABLE PROTOCOL FOR SHEAR WAVE ELASTOGRAPHY OF LOWER LIMB MUSCLES AT REST AND DURING PASSIVE STRETCHING [J].
Dubois, Guillaume ;
Kheireddine, Walid ;
Vergari, Claudio ;
Bonneau, Dominique ;
Thoreux, Patricia ;
Rouch, Philippe ;
Tanter, Mickael ;
Gennisson, Jean-Luc ;
Skalli, Wafa .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (09) :2284-2291