Impedimetric aptasensor for thrombin detection

被引:5
|
作者
Meini, N. [1 ,2 ]
Farre, C. [1 ]
Chaix, C. [1 ]
Kherrat, K. [2 ]
Dzyadevych, S. [3 ]
Jaffrezic-Renault, N. [1 ]
机构
[1] Univ Lyon 1, Analyt Chem Lab, 43 Blvd 11 Novembre 1918, F-69622 Villeurbanne, France
[2] Badji Mokhtar Univ Annaba, Lab Wnvironm Engn, Annaba 23000, Algeria
[3] Natl Acad Sci Ukraine, Inst Mol Biol & Genet, Lab Biomol Elect, UA-03143 Kiev, Ukraine
来源
EUROSENSORS XXV | 2011年 / 25卷
关键词
aptamer; thrombin; electrochemical impedance spectroscopy (EIS); aptasensor;
D O I
10.1016/j.proeng.2011.12.361
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The goal of this work is to develop an impedimetric aptasensor sensitive, selective and stable for detection of thrombin. Thiol modified aptamer sequence being grafted on gold electrode, the faradic electrochemical impedance measurements allow the direct detection of thrombin in the range of 3.1-200 ngmL(-1) with a detection limit of 3.1 ngmL(-1) (80 fM). This study demonstrates that these aptasensors exhibit high sensitivity, high selectivity (compared to a model protein, BSA), stability and reproducibility. (C) 2011 Published by Elsevier Ltd.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Magnetic nanoparticle-linked colorimetric aptasensor for the detection of thrombin
    Zhang, Zhanxia
    Wang, Zhongjun
    Wang, Xiaolei
    Yang, Xiurong
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 147 (02) : 428 - 433
  • [32] An "off-on" phosphorescent aptasensor for the detection of thrombin based on PRET
    Xiong, Yan
    Liang, Meiyu
    Cheng, Yue
    Zou, Jiarui
    Li, Yan
    ANALYST, 2019, 144 (01) : 161 - 171
  • [33] A sensitive homogenous aptasensor based on tetraferrocene labeling for thrombin detection
    Cheng, Lin
    Xu, Chen
    Cui, Hanfeng
    Liao, Fusheng
    Hong, Nian
    Ma, Guangqiang
    Xiong, Jun
    Fan, Hao
    ANALYTICA CHIMICA ACTA, 2020, 1111 : 1 - 7
  • [34] Graphene Fluorescence Resonance Energy Transfer Aptasensor for the Thrombin Detection
    Chang, Haixin
    Tang, Longhua
    Wang, Ying
    Jiang, Jianhui
    Li, Jinghong
    ANALYTICAL CHEMISTRY, 2010, 82 (06) : 2341 - 2346
  • [35] Three different signal amplification strategies for the impedimetric sandwich detection of thrombin
    Ocana, Cristina
    del Valle, Manel
    ANALYTICA CHIMICA ACTA, 2016, 912 : 117 - 124
  • [36] Carbon nanotube-enhanced electrochemical aptasensor for the detection of thrombin
    Liu, Xiaorong
    Li, Yan
    Zheng, Jianbin
    Zhang, Juncai
    Sheng, Qinglin
    TALANTA, 2010, 81 (4-5) : 1619 - 1624
  • [37] AgNPs/QDs@GQDs nanocomposites developed as an ultrasensitive impedimetric aptasensor for ractopamine detection
    Roushani, Mahmoud
    Ghanbarzadeh, Mahsa
    Shandost-Fard, Faezeh
    Sahraei, Reza
    Soheyli, Ehsan
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 108 (108):
  • [38] Impedimetric aptasensor based on zirconium–cobalt metal–organic framework for detection of carcinoembryonic antigen
    Yingpan Song
    Kun Chen
    Senrui Li
    Linghao He
    Minghua Wang
    Nan Zhou
    Miao Du
    Microchimica Acta, 2022, 189
  • [39] Impedimetric aptasensor based on highly porous gold for sensitive detection of acetamiprid in fruits and vegetables
    Xu, Yiwei
    Zhang, Wen
    Shi, Jiyong
    Li, Zhihua
    Huang, Xiaowei
    Zou, Xiaobo
    Tan, Weilong
    Zhang, Xinai
    Hu, Xuetao
    Wang, Xin
    Liu, Chao
    FOOD CHEMISTRY, 2020, 322
  • [40] Dendrimer enriched single-use aptasensor for impedimetric detection of activated protein C
    Erdem, Arzum
    Congur, Gulsah
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2014, 117 : 338 - 345