Numerical study of the linear polarisation resistance technique applied to reinforced concrete for corrosion assessment

被引:20
作者
Clement, A. [1 ]
Laurens, S. [1 ]
Arliguie, G. [1 ]
Deby, F. [1 ]
机构
[1] Univ Toulouse, UPS, INSA, LMDC, Toulouse, France
关键词
corrosion; steel reinforced concrete; linear polarisation resistance; on-site measurement; numerical simulation; THEORETICAL-ANALYSIS; STEEL; MODELS;
D O I
10.1080/19648189.2012.668012
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The linear polarisation resistance (LPR) technique is increasingly being implemented to assess the corrosion rate of steel reinforcements in concrete. However, a lack of reliability is often observed experimentally. In order to improve the physical comprehension of the LPR technique, FEM simulations were performed. Several measurement devices using annular and rectangular probe geometries were simulated and the numerical experimentation allowed the relevance of RILEM recommendations for on-site measurements to be tested. It was shown that the LPR measurement using annular counter-electrodes with confining devices was a real three-dimensional physical problem and the non-uniform distribution of the polarising current on the steel surface is actually a major source of error since it is not taken into account by the usual protocols. Moreover, it was found that some complexity was induced by the use of guard-rings.
引用
收藏
页码:491 / 504
页数:14
相关论文
共 18 条
  • [1] Test methods for on-site corrosion rate measurement of steel reinforcement in concrete by means of the polarization resistance method
    Andrade, C
    Alonso, C
    Gulikers, J
    Polder, R
    Cigna, R
    Vennesland, O
    Salta, M
    Raharinaivo, A
    Elsener, B
    [J]. MATERIALS AND STRUCTURES, 2004, 37 (273) : 623 - 643
  • [2] EFFECT OF CURRENT DISTRIBUTION ON CORROSION RATE MEASUREMENTS IN REINFORCED-CONCRETE
    FELIU, S
    GONZALEZ, JA
    ANDRADE, C
    [J]. CORROSION, 1995, 51 (01) : 79 - 86
  • [3] Gepraegs O., 2005, J. ASTM Int, V2, DOI [10.1520/JAI11789, DOI 10.1520/JAI11789]
  • [4] Numerical models for the propagation period of reinforcement corrosion - Comparison of a case study calculated by different researchers
    Gulikers, J.
    Raupach, M.
    [J]. MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2006, 57 (08): : 618 - 627
  • [5] Theoretical considerations on the supposed linear relationship between concrete resistivity and corrosion rate of steel reinforcement
    Gulikers, J
    [J]. MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2005, 56 (06): : 393 - 403
  • [6] Janusz F, 1993, CONDITION EVALUATION, V2
  • [7] POLARIZATION CURRENT DISTRIBUTION AND ELECTROCHEMICAL IMPEDANCE RESPONSE OF REINFORCED-CONCRETE WHEN USING GUARD RING ELECTRODES
    KRANC, SC
    SAGUES, AA
    [J]. ELECTROCHIMICA ACTA, 1993, 38 (14) : 2055 - 2061
  • [8] Comparison of guarded and unguarded linear polarization CCD devices with weight loss measurements
    Liu, YP
    Weyers, RE
    [J]. CEMENT AND CONCRETE RESEARCH, 2003, 33 (07) : 1093 - 1101
  • [9] Influence of steel-concrete interface condition on galvanic corrosion currents in carbonated concrete
    Nasser, A.
    Clement, A.
    Laurens, S.
    Castel, A.
    [J]. CORROSION SCIENCE, 2010, 52 (09) : 2878 - 2890
  • [10] Corrosion rate of steel in concrete: evaluation of confinement techniques for on-site corrosion rate measurements
    Nygaard, Peter V.
    Geiker, Mette R.
    Elsener, Bernhard
    [J]. MATERIALS AND STRUCTURES, 2009, 42 (08) : 1059 - 1076