Measurement of density variations in tablets using X-ray computed tomography

被引:158
|
作者
Sinka, IC [1 ]
Burch, SF
Tweed, JH
Cunningham, JC
机构
[1] Merck Sharp & Dohme Ltd, Hoddesdon EN11 9BU, Herts, England
[2] AEA Technol Plc, Culham Sci Ctr, Abingdon OX14 3ED, Oxon, England
[3] Merck & Co Inc, West Point, PA 19486 USA
关键词
X-ray computed tomography; density distribution; tablet;
D O I
10.1016/j.ijpharm.2003.11.022
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
In this paper the application of X-ray computed tomography (CT) to measure the material density distribution in pharmaceutical tablets is discussed, X-ray CT is a non-destructive inspection technique which provides cross-sectional images in different planes through a component. The CT image values provide information on the local X-ray attenuation coefficients. For a particular material and X-ray energy, X-ray attenuation is approximately proportional to material density. Determination of quantitative density distributions requires consideration of non-linear instrumental effects including scatter and "beam hardening". Density maps in tablets manufactured under controlled conditions are presented. The results are discussed with reference to the local properties of the material within the tablet and the tablet design features. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:215 / 224
页数:10
相关论文
共 50 条
  • [31] VIRTUAL UNROLLING USING X-RAY COMPUTED TOMOGRAPHY
    Allegra, D.
    Ciliberto, E.
    Ciliberto, P.
    Milotta, F. L. M.
    Petrillo, G.
    Stanco, F.
    Trombatore, C.
    2015 23RD EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2015, : 2864 - 2868
  • [32] Density estimations and comparisons of a fragmented single fiber using X-ray computed tomography
    Wataru Tadano
    Eishi Tanabe
    Jens R. Stellhorn
    Kenji Komaguchi
    Shinjiro Hayakawa
    Analytical Sciences, 2023, 39 : 235 - 240
  • [33] Measurement of Roundness for an X-Ray Mono-Capillary Optic by Using Computed Tomography
    Kwon Su Chon
    Journal of the Korean Physical Society, 2019, 74 : 901 - 906
  • [34] Estimation of measurement uncertainties in X-ray computed tomography metrology using the substitution method
    Muller, P.
    Hiller, J.
    Dai, Y.
    Andreasen, J. L.
    Hansen, H. N.
    De Chiffre, L.
    CIRP JOURNAL OF MANUFACTURING SCIENCE AND TECHNOLOGY, 2014, 7 (03) : 222 - 232
  • [35] Measurement uncertainty evaluation in dimensional X-ray computed tomography using the bootstrap method
    Jochen Hiller
    Gianfranco Genta
    Giulio Barbato
    Leonardo De Chiffre
    Raffaello Levi
    International Journal of Precision Engineering and Manufacturing, 2014, 15 : 617 - 622
  • [36] Measurement of Roundness for an X-Ray Mono-Capillary Optic by Using Computed Tomography
    Chon, Kwon Su
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2019, 74 (09) : 901 - 906
  • [37] Effects of X-Ray Dose On Rhizosphere Studies Using X-Ray Computed Tomography
    Zappala, Susan
    Helliwell, Jonathan R.
    Tracy, Saoirse R.
    Mairhofer, Stefan
    Sturrock, Craig J.
    Pridmore, Tony
    Bennett, Malcolm
    Mooney, Sacha J.
    PLOS ONE, 2013, 8 (06):
  • [38] Measurement Uncertainty Evaluation in Dimensional X-ray Computed Tomography Using the Bootstrap Method
    Hiller, Jochen
    Genta, Gianfranco
    Barbato, Giulio
    De Chiffre, Leonardo
    Levi, Raffaello
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2014, 15 (04) : 617 - 622
  • [39] High spatial resolution x-ray luminescence computed tomography and x-ray fluorescence computed tomography
    Dai, Xianjin
    Sivasubramanian, Kathyayini
    Xing, Lei
    MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS V, 2019, 10862
  • [40] Characterization of Pharmaceutical Tablets by X-ray Tomography
    Vijayakumar, Jaianth
    Goudarzi, Niloofar Moazami
    Eeckhaut, Guy
    Schrijnemakers, Koen
    Cnudde, Veerle
    Boone, Matthieu N.
    PHARMACEUTICALS, 2023, 16 (05)