Experimental Investigation of Heat transfer and Friction Factor Characteristics with Triangular-cut Twisted Tape (TCTT) Inserts

被引:1
作者
Sivakumar, K. [1 ]
Rajan, K. [2 ]
机构
[1] Bharath Inst Higher Educ & Res, Dept Mech Engn, Chennai, Tamil Nadu, India
[2] Dr MGR Educ & Res Inst, Dept Mech Engn, Chennai, Tamil Nadu, India
关键词
Triangular-cut twisted; Heat transfer rate; Plain twisted; Twist ratio; Friction factor; CIRCULAR TUBE; PRESSURE-DROP; LAMINAR-FLOW; TURBULENT-FLOW;
D O I
10.1007/s40010-018-0573-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
An experiment was conducted to investigate the heat transfer characteristics and friction factor characteristics of a concentric tube fitted with triangular-cut twisted tape (TCTT) insert with a twist ratio Y of 5.4 and depth of triangular cut of 1.2 cm, which were studied for laminar flow. This investigation also is used to find the heat transfer coefficient, Nusselt number and Reynolds number. The heat transfer enhancement was caused with the flow of fluid between the plain twisted tapes and TCTT. The experimental value of plain tube and triangular-cut twisted tube obtained from the experimental work and these two statistical data were compared with the results. The results show that the enhancement of heat transfer rate induced with plain and TCTT inserts increases with the increase in Reynolds number. The Reynolds numbers were varied in the range of 5710-18,366. The Reynolds number in the tube with triangular- cut twisted tape insert were enhanced by 1.1-1.3 times compared with smooth twisted tape inserts. The configuration of TCTT insert offered higher heat transfer rate and friction factor than that of the plain twisted inserts.
引用
收藏
页码:353 / 357
页数:5
相关论文
共 31 条
  • [1] Effect of twisted tape insert on heat transfer and pressure drop in horizontal evaporators for the flow of R-134a
    Akhavan-Behabadi, M. A.
    Kumar, Ravi
    Mohammadpour, A.
    Jamali-Asthiani, M.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (05): : 922 - 930
  • [2] Pressure drop and heat transfer comparison for both microfin tube and twisted-tape inserts in laminar flow
    Al-Fahed, S
    Chamra, LM
    Chakroun, W
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1998, 18 (04) : 323 - 333
  • [3] Effect of tube-tape clearance on heat transfer for fully developed turbulent flow in a horizontal isothermal tube
    AlFahed, S
    Chakroun, W
    [J]. INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 1996, 17 (02) : 173 - 178
  • [4] Amin A, 2013, P 4 GLOB ENG SCI TEC
  • [5] Heat transfer and pressure drop in tube with broken twisted tape insert
    Chang, Shyy Woei
    Yang, Tsun Lirng
    Liou, Jin Shuen
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2007, 32 (02) : 489 - 501
  • [6] NUMERICAL PREDICTION OF LAMINAR-FLOW AND HEAT-TRANSFER CHARACTERISTICS IN A TUBE FITTED WITH REGULARLY SPACED TWISTED-TAPE ELEMENTS
    DATE, AW
    SAHA, SK
    [J]. INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 1990, 11 (04) : 346 - 354
  • [7] Du Plessis J.P., 1983, P INT C NUM METH LAM, P775
  • [8] Influence of combined non-uniform wire coil and twisted tape inserts on thermal performance characteristics
    Eiamsa-ard, S.
    Nivesrangsan, P.
    Chokphoemphun, S.
    Promvonge, P.
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (07) : 850 - 856
  • [9] Convective heat transfer in a circular tube with short-length twisted tape insert
    Eiamsa-ard, Smith
    Thianpong, Chinaruk
    Eiamsa-ard, Petpices
    Promvonge, Pongjet
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2009, 36 (04) : 365 - 371
  • [10] Experimental investigation of heat transfer and flow friction in a circular tube fitted with regularly spaced twisted tape elements
    Eiamsa-ard, Smith
    Thianpong, Chinaruk
    Promvonge, Pongjet
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2006, 33 (10) : 1225 - 1233