Wearable soft electrochemical microfluidic device integrated with iontophoresis for sweat biosensing

被引:66
作者
Bolat, Gulcin [1 ]
De la Paz, Ernesto [1 ]
Azeredo, Nathalia F. [1 ,2 ]
Kartolo, Michael [1 ]
Kim, Jayoung [1 ]
de Loyola e Silva, Andre Neirdert [1 ]
Rueda, Ricardo [1 ]
Brown, Christopher [1 ]
Angnes, Lucio [2 ]
Wang, Joseph [1 ]
Sempionatto, Juliane R. [1 ]
机构
[1] Univ Calif San Diego, Dept NanoEngn, La Jolla, CA 92093 USA
[2] Univ Sao Paulo, Dept Fundamental Chem, Inst Chem, Sao Paulo, Brazil
关键词
Stimulated sweat; Sweat glucose; Iontophoresis; Sweat sensor; Wearable sensors; Epidermal microfluidic;
D O I
10.1007/s00216-021-03865-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A soft and flexible wearable sweat epidermal microfluidic device capable of simultaneously stimulating, collecting, and electrochemically analyzing sweat is demonstrated. The device represents the first system integrating an iontophoretic pilocarpine delivery system around the inlet channels of epidermal polydimethylsiloxane (PDMS) microfluidic device for sweat collection and analysis. The freshly generated sweat is naturally pumped into the fluidic inlet without the need of exercising. Soft skin-mounted systems, incorporating non-invasive, on-demand sweat sampling/analysis interfaces for tracking target biomarkers, are in urgent need. Existing skin conformal microfluidic-based sensors for continuous monitoring of target sweat biomarkers rely on assays during intense physical exercising. This work demonstrates the first example of combining sweat stimulation, through transdermal pilocarpine delivery, with sample collection through a microfluidic channel for real-time electrochemical monitoring of sweat glucose, in a fully integrated soft and flexible multiplexed device which eliminates the need of exercising. The on-body operational performance and layout of the device were optimized considering the fluid dynamics and evaluated for detecting sweat glucose in several volunteers. Furthermore, the microfluidic monitoring device was integrated with a real-time wireless data transmission system using a flexible electronic board PCB conformal with the body. The new microfluidic platform paves the way to real-time non-invasive monitoring of biomarkers in stimulated sweat samples for diverse healthcare and wellness applications.
引用
收藏
页码:5411 / 5421
页数:11
相关论文
共 50 条
[1]   A wearable patch for continuous monitoring of sweat electrolytes during exertion [J].
Alizadeh, Azar ;
Burns, Andrew ;
Lenigk, Ralf ;
Gettings, Rachel ;
Ashe, Jeffrey ;
Porter, Adam ;
McCaul, Margaret ;
Barrett, Ruairi ;
Diamond, Dermot ;
White, Paddy ;
Skeath, Perry ;
Tomczak, Melanie .
LAB ON A CHIP, 2018, 18 (17) :2632-2641
[2]   Wearable Sensors for Biochemical Sweat Analysis [J].
Bandodkar, Amay J. ;
Jeang, William J. ;
Ghaffari, Roozbeh ;
Rogers, John A. .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 12, 2019, 12 :1-22
[3]   Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat [J].
Bandodkar, Amay J. ;
Gutruf, Philipp ;
Choi, Jungil ;
Lee, KunHyuck ;
Sekine, Yurina ;
Reeder, Jonathan T. ;
Jeang, William J. ;
Aranyosi, Alexander J. ;
Lee, Stephen P. ;
Model, Jeffrey B. ;
Ghaffari, Roozbeh ;
Su, Chun-Ju ;
Leshock, John P. ;
Ray, Tyler ;
Verrillo, Anthony ;
Thomas, Kyle ;
Krishnamurthi, Vaishnavi ;
Han, Seungyong ;
Kim, Jeonghyun ;
Krishnan, Siddharth ;
Hang, Tao ;
Rogers, John A. .
SCIENCE ADVANCES, 2019, 5 (01)
[4]   Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study [J].
Bandodkar, Amay J. ;
Jia, Wenzhao ;
Yardimci, Ceren ;
Wang, Xuan ;
Ramirez, Julian ;
Wang, Joseph .
ANALYTICAL CHEMISTRY, 2015, 87 (01) :394-398
[5]   Soft, Skin-Interfaced Microfluidic Systems with Passive Galvanic Stopwatches for Precise Chronometric Sampling of Sweat [J].
Bandodkar, Array J. ;
Choi, Jungil ;
Lee, Stephen P. ;
Jeang, William J. ;
Agyare, Prophecy ;
Gutruf, Philipp ;
Wang, Siqing ;
Sponenburg, Rebecca A. ;
Reeder, Jonathan T. ;
Schon, Stephanie ;
Ray, Tyler R. ;
Chen, Shulin ;
Mehta, Sunita ;
Ruiz, Savanna ;
Rogers, John A. .
ADVANCED MATERIALS, 2019, 31 (32)
[6]   Glove-based sensors for multimodal monitoring of natural sweat [J].
Bariya, Mallika ;
Li, Lu ;
Ghattamaneni, Rahul ;
Ahn, Christine Heera ;
Hnin Yin Yin Nyein ;
Tai, Li-Chia ;
Javey, Ali .
SCIENCE ADVANCES, 2020, 6 (35)
[7]   Electrochemical multi-analyte point-of-care perspiration sensors using on-chip three-dimensional graphene electrodes [J].
Bauer, Meike ;
Wunderlich, Lukas ;
Weinzierl, Florian ;
Lei, Yongjiu ;
Duerkop, Axel ;
Alshareef, Husam N. ;
Baeumner, Antje J. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (03) :763-777
[8]   Application of Microfluidics in Wearable Devices [J].
Chen, Guo ;
Zheng, Jiangen ;
Liu, Liyu ;
Xu, Lei .
SMALL METHODS, 2019, 3 (12)
[9]   Recent developments in sensors for wearable device applications [J].
Cheng, Yuemeng ;
Wang, Kan ;
Xu, Hao ;
Li, Tangan ;
Jin, Qinghui ;
Cui, Daxiang .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (24) :6037-6057
[10]   Soft, skin-mounted microfluidic systems for measuring secretory fluidic pressures generated at the surface of the skin by eccrine sweat glands [J].
Choi, Jungil ;
Xue, Yeguang ;
Xia, Wei ;
Ray, Tyler R. ;
Reeder, Jonathan T. ;
Bandodkar, Amay J. ;
Kang, Daeshik ;
Xu, Shuai ;
Huang, Yonggang ;
Rogers, John A. .
LAB ON A CHIP, 2017, 17 (15) :2572-2580