Performance evaluation of automatic anatomy segmentation algorithm on repeat or four-dimensional computed tomography images using deformable image registration method

被引:96
作者
Wang, He [1 ]
Adam, S. Garden [2 ]
Zhang, Lifei [1 ]
Wei, Xiong [2 ]
Ahamad, Anesa [2 ]
Kuban, Deborah A. [2 ]
Komaki, Ritsuko [2 ]
O'Daniel, Jennifer [1 ]
Zhang, Yongbin [1 ]
Mohan, Radhe [1 ]
Dong, Lei [1 ]
机构
[1] Univ Texas Houston, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas Houston, MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2008年 / 72卷 / 01期
关键词
auto-contouring; deformable image registration; adaptive radiotherapy; image-guided radiotherapy; auto-segmentation;
D O I
10.1016/j.ijrobp.2008.05.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Auto-propagation of anatomic regions of interest from the planning computed tomography (CT) scan to the daily CT is an essential step in image-guided adaptive radiotherapy. The goal of this study was to quantitatively evaluate the performance of the algorithm in typical clinical applications. Methods and Materials: We had previously adopted an image intensity-based deformable registration algorithm to find the correspondence between two images. In the present study, the regions of interest delineated on the planning CT image were mapped onto daily CT or four-dimensional CT images using the same transformation. Postprocessing methods, such as boundary smoothing and modification, were used to enhance the robustness of the algorithm. Auto-propagated contours for 8 head-and-neck cancer patients with a total of 100 repeat CT scans, 1 prostate patient with 24 repeat CT scans, and 9 lung cancer patients with a total of 90 four-dimensional CT images were evaluated against physician-drawn contours and physician-modified deformed contours using the volume overlap index and mean absolute surface-to-surface distance. Results: The deformed contours were reasonably well matched with the daily anatomy on the repeat CT images. The volume overlap index and mean absolute surface-to-surface distance was 83% and 1.3 mm, respectively, compared with the independently drawn contours. Better agreement (>97% and <0.4 mm) was achieved if the physician was only asked to correct the deformed contours. The algorithm was also robust in the presence of random noise in the image. Conclusion: The deformable algorithm might be an effective method to propagate the planning regions of interest to subsequent CT images of changed anatomy, although a final review by physicians is highly recommended. (C) 2008 Elsevier Inc.
引用
收藏
页码:210 / 219
页数:10
相关论文
共 42 条
  • [1] Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system
    Barker, JL
    Garden, AS
    Ang, KK
    O'Daniel, JC
    Wang, H
    Court, LE
    Morrison, WH
    Rosenthal, DI
    Chao, KSC
    Tucker, SL
    Mohan, R
    Dong, L
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04): : 960 - 970
  • [2] A dose-escalation trial with the adaptive radiotherapy process as a delivery system in localized prostate cancer: Analysis of chronic toxicity
    Brabbins, D
    Martinez, A
    Yan, D
    Lockman, D
    Wallace, M
    Gustafson, G
    Chen, P
    Vicini, F
    Wong, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (02): : 400 - 408
  • [3] Intraobserver and interobserver variability in GTV delineation on FDG-PET-CT images of head and neck cancers
    Breen, Stephen L.
    Publicover, Julia
    De Silva, Shiroma
    Pond, Greg
    Brock, Kristy
    O'Sullivan, Brian
    Cummings, Bernard
    Dawson, Laura
    Keller, Anne
    Kim, John
    Ringash, Jolie
    Yu, Eugene
    Hendler, Aaron
    Waldron, John
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (03): : 763 - 770
  • [4] Accuracy of finite element model-based multi-organ deformable image registration
    Brock, KK
    Sharpe, MB
    Dawson, LA
    Kim, SM
    Jaffray, DA
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1647 - 1659
  • [5] Evaluation of mechanical precision and alignment uncertainties for an integrated CT/LINAC system
    Court, L
    Rosen, I
    Mohan, R
    Dong, L
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1198 - 1210
  • [6] An automatic CT-guided adaptive radiation therapy technique by online modification of multileaf collimator leaf positions for prostate cancer
    Court, LE
    Dong, L
    Lee, AK
    Cheung, R
    Bonnen, MD
    O'Daniel, J
    Wang, H
    Mohan, R
    Kuban, D
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (01): : 154 - 163
  • [7] Evaluation of a contour-alignment technique for CT-guided prostate radiotherapy: An intra- and interobserver study
    Court, LE
    Dong, L
    Taylor, N
    Ballo, M
    Kitamura, K
    Lee, AK
    O'Daniel, J
    White, RA
    Cheung, R
    Kuban, D
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (02): : 412 - 418
  • [8] Automatic registration of the prostate for computed-tomography-guided radiotherapy
    Court, LE
    Dong, L
    [J]. MEDICAL PHYSICS, 2003, 30 (10) : 2750 - 2757
  • [9] Davis B, 2004, MED PHYS, V31, P1780
  • [10] Guidance document on delivery, treatment planning, and clinical implementation of IMRT: Report of the IMRT subcommittee of the AAPM radiation therapy committee
    Ezzell, GA
    Galvin, JM
    Low, D
    Palta, JR
    Rosen, I
    Sharpe, MB
    Xia, P
    Xiao, Y
    Xing, L
    Yu, CX
    [J]. MEDICAL PHYSICS, 2003, 30 (08) : 2089 - 2115