Dynamic Behavior of Supertall Building with Active Control System during Super Typhoon Mangkhut

被引:54
作者
Zhou, Kang [1 ]
Li, Qiu-Sheng [1 ]
Li, Xiao [1 ]
机构
[1] City Univ Hong Kong, Dept Architecture & Civil Engn, Kowloon, Hong Kong 999077, Peoples R China
基金
中国国家自然科学基金;
关键词
Skyscraper; Field measurement; Structural dynamic characteristics; Wind effect; Super typhoon; Vibration control; Active tuned mass damper; Structural damage; TUNED MASS DAMPERS; WIND-TUNNEL; FULL-SCALE; FIELD-MEASUREMENTS; VIBRATION CONTROL; TALL BUILDINGS; PERFORMANCE; TOWER; ATMD;
D O I
10.1061/(ASCE)ST.1943-541X.0002626
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents observations of structural dynamic characteristics and wind-induced responses of a 600-m-high skyscraper installed with an active tuned mass damper (ATMD) system during super typhoon Mangkhut. The structural dynamic characteristics (i.e., natural frequency, damping ratio, and mode shape) of the skyscraper are estimated along the structural modal directions based on the measurements during the typhoon, which are in good agreement with those determined by the finite element method and forced vibration test. The wind-induced responses and damping ratios of the skyscraper with and without the operation of the ATMD system are investigated, and the results show that the ATMD system can suppress the structural responses by mitigating the vibrations of the fundamental sway modes. Global damage evaluation indicates that there is no evident structural damage occurred on the skyscraper during the violent typhoon event. This paper aims to further the understanding of wind effects on supertall buildings under extreme wind conditions and provide useful information for the wind-resistant design and development of vibration control techniques for future skyscrapers. (C) 2020 American Society of Civil Engineers.
引用
收藏
页数:15
相关论文
共 58 条
[1]   DYNAMIC CHARACTERIZATION OF MULTIPLE TUNED MASS DAMPERS AND SOME DESIGN FORMULAS [J].
ABE, M ;
FUJINO, Y .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1994, 23 (08) :813-835
[2]  
AIJ, 2019, AIJ REC LOADS BUILD
[3]   Simple ATMD control methodology for tall buildings subject to wind loads [J].
Ankireddi, S ;
Yang, HTY .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (01) :83-91
[4]   Field observations on modal properties of two tall buildings under strong wind [J].
Au, Siu-Kui ;
Zhang, Feng-Liang ;
To, Ping .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2012, 101 :12-23
[5]   Ambient vibration studies for system identification of tall buildings [J].
Brownjohn, JMW .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2003, 32 (01) :71-95
[6]   Tuned tandem mass dampers-inerters with broadband high effectiveness for structures under white noise base excitations [J].
Cao, Liyuan ;
Li, Chunxiang .
STRUCTURAL CONTROL & HEALTH MONITORING, 2019, 26 (04)
[7]   Structural damage identification using damping: a compendium of uses and features [J].
Cao, M. S. ;
Sha, G. G. ;
Gao, Y. F. ;
Ostachowicz, W. .
SMART MATERIALS AND STRUCTURES, 2017, 26 (04)
[8]   Comparison of methods for computing equivalent viscous damping ratios of structures with added viscous damping [J].
Charney, Finley A. ;
McNamara, Robert J. .
JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (01) :32-44
[9]  
China Association for Engineering Construction Standardization, 2010, JGJ32010 CHIN ASS EN
[10]   The observed wander of the natural frequencies in a structure [J].
Clinton, JF ;
Bradford, SC ;
Heaton, TH ;
Favela, J .
BULLETIN OF THE SEISMOLOGICAL SOCIETY OF AMERICA, 2006, 96 (01) :237-257