Automated flow cytometry analysis of peritoneal dialysis fluid

被引:11
作者
Penders, J
Fiers, T
Dhondt, AM
Claeys, G
Delanghe, JR
机构
[1] Ghent Univ Hosp, Clin Chem Lab, Dept Clin Chem Microbiol & Immunol, B-9000 Ghent, Belgium
[2] Ghent Univ Hosp, Dept Nephrol, B-9000 Ghent, Belgium
关键词
flow cytometry; infection; microorganisms; peritoneal dialysis; UF-100;
D O I
10.1093/ndt/gfg552
中图分类号
R3 [基础医学]; R4 [临床医学];
学科分类号
1001 ; 1002 ; 100602 ;
摘要
Background. Recently, the Sysmex UF-100 flow cytometer has been developed to automate urinalysis. We have evaluated this instrument to explore the possibilities of flow cytometry in the analysis of peritoneal dialysis fluid (PD) and have compared the obtained data with those of counting chamber techniques, biochemical analysis and bacterial culture. Methods. UF-100 data were correlated with microscopy and biochemical data in 135 PD samples. Microbiological analysis was performed in 63 suspected cases of peritonitis. Results. Good agreement (P < 0.001) was obtained between UF-100 and microscopy data for leukocytes (r = 0.825). UF-100 bacterial count correlated (P < 0.001) with UF-100 leukocyte count (r=0.549). UF-100 bacterial counts were unreliable in samples where interference by blood platelets was observed Another major problem was the UF-100 'bacterial' background signal in sterile PD samples. Yeast cells were detected by the flow cytometer in spiked samples. Conclusions. Flow cytometry of PD with the UF-100 offers a rapid and reliable leukocyte count. Sensitivity of the 'bacterial' channel count in predicting positive culture exceeds the sensitivity of conventional Gram stain. Furthermore, additional semi-quantitative information is provided regarding the presence of yeasts.
引用
收藏
页码:463 / 468
页数:6
相关论文
共 20 条
  • [1] Afthentopoulos I E, 1998, Adv Ren Replace Ther, V5, P157
  • [2] Flow cytometry as a new method to quantify the cellular content of human saliva and its relation to gingivitis
    Aps, JKM
    Van den Maagdenberg, K
    Delanghe, JR
    Martens, LC
    [J]. CLINICA CHIMICA ACTA, 2002, 321 (1-2) : 35 - 41
  • [3] Ben-Ezra J, 1998, CLIN CHEM, V44, P92
  • [4] Dalaman G, 1998, CLIN CHEM, V44, P1680
  • [5] Davies SJ, 1996, NEPHROL DIAL TRANSPL, V11, P498
  • [6] The role of automated urine particle flow cytometry in clinical practice
    Delanghe, JR
    Kouri, TT
    Huber, AR
    Hannemann-Pohl, K
    Guder, WG
    Lun, A
    Sinha, P
    Stamminger, G
    Beier, L
    [J]. CLINICA CHIMICA ACTA, 2000, 301 (1-2) : 1 - 18
  • [7] GOKAL R, 1987, LANCET, V2, P1105
  • [8] Peritoneal dialysis
    Gokal, R
    Mallick, NP
    [J]. LANCET, 1999, 353 (9155) : 823 - 828
  • [9] GORBANBRENNAN N, 1993, PERITON DIALYSIS INT, V13, P140
  • [10] Kouri TT, 1999, AM J CLIN PATHOL, V112, P25