Pollutant Transport in Geomedia Using X-ray Computed Tomography

被引:0
|
作者
Anderson, S. H. [1 ]
Liu, X. [1 ]
机构
[1] Univ Missouri, Dept Soil Environm & Atmospher Sci, Columbia, MO 65211 USA
来源
关键词
adsorption processes; spatial analysis; retardation coefficient; FRACTAL DIMENSION; PARAMETERS;
D O I
10.1016/j.procs.2011.08.089
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Computed tomography (CT) measurement systems have been introduced as a method to measure fluid transport at the macropore-scale to estimate transport parameters. The objective of this study was to use x-ray CT methods to measure transport of iodophenol solution in geomedia columns and estimate spatial distributions of chemical retardation. An initial CT-measured breakthrough curve experiment was conducted with potassium iodide to spatially estimate pore-water velocity and dispersivity in the geomedia core, with a subsequent transport experiment with iodophenol to estimate the spatial distribution of chemical retardation. A geomedia core was removed from the surface horizon of Sarpy loamy sand (Typic Udispamment). Spatial distributions followed a fractal pattern with dimension values similar among pore-water velocity, dispersivity and retardation coefficient parameters. The retardation coefficient estimated using CT methods was similar compared to the dynamic fluid experiment indicating this new method may be appropriate for pollutant transport analysis. This study illustrates that the CT method is useful for evaluating solute transport on a macropore-scale for porous materials. (C) 2011 Published by Elsevier B.V.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Characterizing transport in electrochemical energy conversion devices with X-ray computed tomography
    Zenyuk, Iryna
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254
  • [32] Quasimonochromatic x-ray computed tomography by the balanced filter method using a conventional x-ray source
    Saito, M
    MEDICAL PHYSICS, 2004, 31 (12) : 3436 - 3443
  • [33] DEMONSTRATION OF PHASE-CONTRAST X-RAY COMPUTED-TOMOGRAPHY USING AN X-RAY INTERFEROMETER
    MOMOSE, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 352 (03): : 622 - 628
  • [34] Experimental investigation of solute transport in variably saturated porous media using x-ray computed tomography
    Zhang, Chunwei
    She, Yun
    Hu, Yingxue
    Li, Zijing
    Wang, Weicen
    Patmonoaji, Anindityo
    Suekane, Tetsuya
    PHYSICS OF FLUIDS, 2021, 33 (07)
  • [35] STATISTICAL ASPECTS OF COMPUTED X-RAY TOMOGRAPHY
    CHESLER, DA
    PELC, NJ
    RIEDERER, SJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01): : 130 - 131
  • [36] X-ray computed tomography of ultralightweight metals
    Winter, JM
    Green, RE
    Waters, AM
    Green, WH
    RESEARCH IN NONDESTRUCTIVE EVALUATION, 1999, 11 (04) : 199 - 211
  • [37] X-ray computed tomography for medical imaging
    Hiriyannaiah, HP
    IEEE SIGNAL PROCESSING MAGAZINE, 1997, 14 (02) : 42 - 59
  • [38] Contemporary developments in computed X-ray tomography
    Seibert, JA
    RADIOLOGY, 1998, 209P : 207 - 208
  • [39] Microscopic x-ray luminescence computed tomography
    Zhang, Wei
    Zhu, Dianwen
    Zhang, Kun
    Li, Changqing
    MULTIMODAL BIOMEDICAL IMAGING X, 2015, 9316
  • [40] X-ray computed tomography in life sciences
    Shelley D. Rawson
    Jekaterina Maksimcuka
    Philip J. Withers
    Sarah H. Cartmell
    BMC Biology, 18