Two-Photon Sensors for Proton Derived from 7-Pyridinylbenzo[c] [1,2,5]thiadiazole Receptor

被引:0
作者
Zhao Wei-feng [2 ]
Wang Xiao-mei [1 ]
Luo Jian-fang [1 ]
Tao Xu-tang [3 ]
机构
[1] Suzhou Univ Sci & Technol, Inst Chem & Bioengn, Suzhou 215009, Peoples R China
[2] Soochow Univ, Inst Chem & Mat Sci, Suzhou 215123, Peoples R China
[3] Shandong Univ, State Key Lab Crystal Mat, Jinan 250100, Peoples R China
关键词
Sensor; One-photon fluorescence; Two-photon fluorescence PH-sensor; 4-(pyridine-2-yl)benzothiadiazole; PH SENSOR; CHARGE-TRANSFER; BENZOTHIOXANTHENE; CHROMOPHORES;
D O I
10.3964/j.issn.1000-0593(2011)05-1300-05
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Two new chromophores with carbazole as molecular focal point bearing either one o-pyridine-benzothiadiazole unit or two o-pyridine-benzothiadiazole units at the periphery respectively, named as 2,8-(o-pyridine-benzothiadiazole)-N-ethyl-carbazole (CPTZ1) and 2,8-bis(o-pyridine-benzothiadiazole)-N-ethyl-carbazole (CPTZ2), were synthesized and characterized by IR spectra, (1)H NMR spectra and MS. The influence of proton upon one-photon and two-photon fluorescence about these two compounds was discussed. Stern-Volmer equation gives that the S-V constants (k(SV)(1P)) of one-photon fluorescence (1PF) of CPTZ1 and CPTZ2 are 0.04 and 0.10 L . mol(-1), respectively; while the k(SV)(2P) of two-photon fluorescence (2PF) of CPTZ1 and CPTZ2 are 0.20 and 0.22 L . mol(-1), respectively. Obviously, two-photon (2P) fluorescence detection presented more sensitivity than one-photon (IF) fluorescence response, which exhibits the potential application of two-photon sensor in PH detection.
引用
收藏
页码:1300 / 1304
页数:5
相关论文
共 13 条
  • [1] A novel fluorescence ratiometric pH sensor based on covalently immobilized piperazinyl-1,8-napthalimide and benzothioxanthene
    Li, ZZ
    Niu, CG
    Zeng, GM
    Liu, YG
    Gao, PF
    Huang, GH
    Mao, YA
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01): : 308 - 315
  • [2] Fluorescent imaging of pH with optical sensors using time domain dual lifetime referencing
    Liebsch, G
    Klimant, I
    Krause, C
    Wolfbeis, OS
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (17) : 4354 - 4363
  • [3] LIEBSCH G, 1998, ANAL CHEM, V70, P3892
  • [4] LIU GH, 2005, J FUNCT MAT, V5, P600
  • [5] A pH-sensitive nanotip array imaging sensor
    Liu, YH
    Dam, TH
    Pantano, P
    [J]. ANALYTICA CHIMICA ACTA, 2000, 419 (02) : 215 - 225
  • [6] A long lifetime chemical sensor: study on fluorescence property of fluorescein isothiocyanate and preparation of pH chemical sensor
    Ma, LY
    Wang, HY
    Xie, H
    Xu, LX
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2004, 60 (8-9) : 1865 - 1872
  • [7] Fluorescence ratiometric pH sensor prepared from covalently immobilized porphyrin and benzothioxanthene
    Niu, CG
    Gui, XQ
    Zeng, GM
    Guan, AL
    Gao, PF
    Qin, PZ
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (02) : 349 - 357
  • [8] A ratiometric fluorescence sensor with broad dynamic range based on two pH-sensitive fluorophores
    Niu, CG
    Gui, XQ
    Zeng, GM
    Yuan, XZ
    [J]. ANALYST, 2005, 130 (11) : 1551 - 1556
  • [9] A sensitive and highly stable polypyrrole-based pH sensor with hydroquinone monosulfonate and oxalate co-doping
    Prissanaroon-Ouajai, Walaiporn
    Pigram, Paul J.
    Jones, Robert
    Sirivat, Anuvat
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (02): : 504 - 511
  • [10] The effect of substituent position upon unsymmetrical isomeric diarylethenes bearing a methoxy group
    Pu, Shouzhi
    Fan, Congbin
    Miao, Wenjuan
    Liu, Gang
    [J]. DYES AND PIGMENTS, 2010, 84 (01) : 25 - 35